background image

16

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

W

A

RNI

N

G

H

IGH

 VO

L

T

A

GE

!

D

IS

CO

N

E

CT

 AL

PO

W

E

R

 

BE

F

O

RE

 

SER

VIC

IN

G

 

OR

 

IN

S

T

AL

L

ING

 

TH

IS

 

UN

IT

.  M

UL

T

IP

L

E

 

PO

W

E

R

S

O

UR

CE

S

 

MA

Y

 

BE

 

PR

E

SEN

T

. F

AI

L

U

R

E

 

TO

 

DO

 

SO

 

MA

Y

 

CA

US

E

 

PR

O

PER

T

Y

 

DA

M

A

G

E

P

E

RS

O

N

AL

IN

J

U

R

Y

 

OR

 

DE

A

T

H

.

GPH13(36)H21** WIRING DIAGRAM

WH

NOTE #4

FC

NOTE#2

EM

M1

COM

TR

24V

208-240

NO

EBTDR

NC

3

CONTROL

240

RD

O

PU

208-240/1/60

SUPPLY VOLTAGE

C

CO MP

C

S.A.

S

T1

R

FC

L1

BR

DF1

C

NOTE #5

H

F

RCCF

CM

HVDR

T2

CH

C

DF2

BK

BK

L2

DF1

BK

RD

PU

RD

BK

DF2

HVDR

LVDR

RD

RD

BOX

R

DFT

RD

R

RD

BK

W2

O

BK

K1

K1

M1

NOTE #2

DC

XFMR-C

PU

SPEED

C

BL

XFMR-R

R

G

EBTDR

GR

COM

BL

Y

C

YL

NC

RD

NO

RD

2

24V

BL

208

TR

C

BK

1

PU

COMP

CM

OR

NOTE #3

CH

BR

BR

PU

4

1

PLF

PU

BK

YL

S

BK

RD

BK

5

6

2

3

BUSHING

C R

RD

OR

BL

BR

WH

GR

YL

R

O

C

W2

W1

G

Y

A
T

O

T

S

M

R

E

H

T

T2

T1

RD

NOTE #4

PU

BL

L1

YL

GND

C

L2

PU

BK

6
0

/

/

1

0

4

2

-

8

0

2

HIGH

(TRANS240V)

PU

(M1) RD

BR

FC

LOW

OPTIONAL

2 SPEED

BR

EM

3 SPEED

EM

M2

UP

M2

7

8

9

PU

BL

BR

WH

208-240/1/60   0140G00365 REV. B

RD

RD

BK

BK

RD

YL

BK

BK

RD

DFT

RVC

LPS

COMPONENT LEGEND

BR
C
CH
CM
COMP
DC
DFT
EBTD
R
EM
FC
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

SA
TR

BLOWER INTERLOCK RELAY
CONTACTOR
CRANKCASE HEATER
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRONIC BLOWER TIME DELAY 
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VALVE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

WIRE CODE

BK     BLACK
BL     BLUE
BR     BROWN
GR     GREEN
OR     ORANGE
PU     PURPLE
RD     RED
WH     WHITE
YL     YELLOW

FACTORY WIRING

          LINE VOLTAGE
          LOW VOLTAGE
          OPTIONAL HIGH
          VOLTAGE

FIELD WIRING

          HIGH VOLTAGE
          LOW VOLTAGE

++

EBTDR

R

G

C

DC

DFT

Y

C

DFT

EBTDR

LVDR

W2

O

R

R

1

3

2

LVJB

RD

OR

OR

BL

BL

SEE NOTE #6

SEE NOTE #3

THERMOSTAT

BK

BK

PU

YL

RCCF

RD

RD

SA

YL

H

C

F

BR

BL

BR

BK

(IF USED)
SEE NOTE #5

R

W2

O

W1

G

C

P
L
F

6

5

4

C

Y

O

RVC

2

4

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

NOTES:

1.   REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS 
ORIGINAL (AT
     LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2.  TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR 
"COM" WITH LEAD
     ON EBTDR "M1" OR "M2"
3.  CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
4.  FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES 
FROM TERMINAL 3
    TERMINAL 2 ON TRANSFORMER.
5.  START ASSIST FACTOR EQUIPPED WHEN REQUIRED
6.  USE COPPER CONDUCTORS ONLY
++  USE N.E.C. CLASS 2 WIRE

(COM)BK

4

2

1

3

1

3

3

1

BR

P
L
F

OR

OR

RD

OR

Содержание GPC 13 SEER H Series

Страница 1: ...o system charging and start up Prior to installation thoroughly familiarize yourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed I...

Страница 2: ...PTING TO INSTALL OR REPAIR THIS UNIT WITHOUT SUCH BACKGROUND MAY RESULT IN PRODUCT DAMAGE PERSONAL INJURY OR DEATH AT A MINIMUM INTRODUCTION Checking Product Received Upon receiving the unit inspect i...

Страница 3: ...heat pumps are designed for OUTDOOR USE ONLY This series is available in cooling Capacities of 3 and 5 nominal tons of cooling Op tional field installed heat kits are available in 5 8 10 15 and 20 KW...

Страница 4: ...application minimizes exposed wiring Close to the wall application assures free unobstructed air to the other two sides In more confined application spaces such as corners provide a minimum 10 cleara...

Страница 5: ...the collars and flanges with a proper waterproof sealant See Figure 3 It is strongly encouraged to use appropriately sized ducts based upon the CFM for your application unit s CFM If duct sizing thro...

Страница 6: ...GE DISCONNECT SWITCH LOW VOLTAGE CONNECTORS R COMMON HEAT FAN COOL W Y G THERMOSTAT SUBBASE Y G R W FOR INTERNAL WIRING SEE WIRING LABEL ATTACHED TO UNIT HIGH VOLTAGE POWER WIRING 24 VOLT CONTROL WIRI...

Страница 7: ...now be operating Allow the unit to run 10 minutes make sure cool air is being supplied by the unit 7 Turn the temperature setting to the highest position stopping the unit The indoor blower will cont...

Страница 8: ...is recommended to serve as an indication that the unit will operate normally COMPONENTS 1 Contactor This control is activated closed by the room thermostat for both heating and cooling The contactor...

Страница 9: ...refrigerant circuit external to the compressor This is accomplished with a reversing valve Thus the hot discharge vapor from the compressor is directed to the indoor coil evaporator on the cooling cy...

Страница 10: ...inal DF2 on defrost board and turn on power AIR FLOW MEASUREMENT AND ADJUSTMENT After reviewing section on DUCTING proceed with airflow measurements and adjustments Unit s blower curves in Specificati...

Страница 11: ...e adjusted to the proper amount All package units should be charged to the superheat method at the compressor suction line these are fixed orifice devices For charging in the warmer months 10 F superh...

Страница 12: ...he Heating Cycle Inadequate Air Volume Through Indoor Coil When a heat pump is in the heating cycle the indoor coil is functioning as a condenser The return air filter must always be clean and suffici...

Страница 13: ...k tighten all connections b Compressor stuck grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the compressor c Low voltage connection...

Страница 14: ...BTD R EM FC GND LVJB PLF RCCF SA TR BLOWER INTERLOCK RELAY CONTACTOR CRANKCASE HEATER CONDENSER MOTOR COMPRESSOR ELECTRONIC BLOWER TIME DELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND LOW...

Страница 15: ...OVER CURRENT PROTECTION COMPONENT LEGEND C CM COMP EM GND LVJB PLF RCCF SA TR CONTACTOR CONDENSER MOTOR COMPRESSOR EVAPORATOR MOTOR EQUIPMENT GROUND LOW VOLTAGE JUNCTION BOX FEMALE PLUG CONNECTOR RUN...

Страница 16: ...LOWER INTERLOCK RELAY CONTACTOR CRANKCASE HEATER CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ELECTRONIC BLOWER TIME DELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND HIGH V...

Страница 17: ...ROTECTION COMPONENT LEGEND C CM COMP DC DFT EM GND HVDR LPS LVDR LVJB PLF RVC RCCF SA TR CONTACTOR CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT EVAPORATOR MOTOR EQUIPMENT GROUND HIGH...

Страница 18: ...18 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 19: ...19 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 20: ...ificantly reduce the most frequent causes of product failure They are simple to service and forgiving to operate We use quality materials and components Finally every unit is run tested before it leav...

Отзывы: