without the transformer connected. Resistance should 
read above 20K ohms with an analog meter and above 
4M ohms with a digital meter. If the resistance readings 
are below these values, the power board may be the 
cause of the transformer failure. 

 

Before replacing the 24 V transformer, turn 

OFF

 power to 

the Air Cleaner at the source. 
1.  Remove power box cover. 
2.  Disconnect the secondary leads from the transformer 

to the 24 V terminals on the power board. See Fig. 5. 

3.  Cut the primary leads (to the APS) close to the 

transformer. 

4.  Remove the 2 hex head nuts from the transformer 

studs. 

5.  Remove the transformer. 
6.  Place new transformer over studs and re-install 2 hex 

head nuts to secure into place. 

7.  Connect secondary leads (white) to the 24 V 

terminals on the power board (P1 & P2). 

8.  Wire nut primary leads from APS (cut in Step 3) to 

the primary leads of the new transformer. 

9.  Replace power box cover. 
10. Turn 

ON

 the power to the Air Cleaner and test. 

 

Setting Voltage Of Power Board

 

Voltage on the power board may drop below required 

level when installation area is too damp, too cold, or if 
there is a leakage of water from a humidifier. Voltage on 
power board may be too high when installation area is 
too dry or too hot, or home is in close proximity to hydro 
towers or situated in remote farm land areas. By 
adjusting the HV Adj. potentiometer, the voltage can be 
set to optimum level. A high voltage meter capable of 
measuring 10,000 VDC is required. To test and adjust 
voltage level, perform the following procedure: 
1.  Turn the Air Cleaner 

OFF

2.  Remove the power box cover. 
3.  Connect the ground of the high voltage meter to an 

unpainted surface in the power box. 

4. Turn 

ON

 the Air Cleaner and wait 5 minutes before 

checking voltages to allow voltages on cells to 
stabilize. The cells and ionizing wires must be clean. 

5.  Measure the voltages at HV1 and HV2 on the power 

board.  

6.  Adjust the HV Adj. potentiometer until the voltage 

reading matches the voltage in Table 3. Adjusting the 
potentiometer 

clockwise decreases

 the voltage and 

turning 

counter-clockwise increases

 the voltage. 

7. Turn 

OFF

 the Air Cleaner. 

8.  Remove the high voltage meter. 
9.  Replace the power box cover. 
10. Turn 

ON

 the Air Cleaner. 

 

Setting Approximate Voltage Without High Voltage 
Meter 

A high voltage meter should be used to set the high 

voltage. If one is not available, this method can be used. 
This will only set an approximate voltage. After using this 
method, the voltage should be reset with a high voltage 
meter as soon as possible. 
1.  Remove power box cover. 
2. Turn the HV Adj. potentiometer fully counter-

clockwise. The Air Cleaner may arc or snap at this 
point. 

3.  Turn the HV Adj. potentiometer clockwise until the 

arrow is at the half way point. 

4.  Replace power box cover. 

 
Testing for Voltage At The Cell

 

1.  Open access door to Air Cleaner. 
2.  The cells must be in the Air Cleaner for this test and 

the system fan should be on high speed. 

3.  Turn the Air Cleaner 

ON

 and press the safety 

interlock switch lever.  

4.  Place a plastic handled screwdriver into the direction 

arrow slot. Do not apply excessive force. 

5.  If there is a good snap then there is high voltage at 

the cell. 

 

Testing Cell For Bad Contacts

 

1.  Open access door to Air Cleaner. 
2.  The cells must be in the Air Cleaner for this test and 

the system fan should be on high speed. 

3.  Turn the Air Cleaner 

ON

 and press the safety 

interlock switch lever.  

4.  Place a plastic handled screwdriver into the direction 

arrow slot. Do not apply excessive force. 

5.  There should be an initial snap when the plates are 

shorted, then no sound. If a hissing occurs, then 
there is a bad contact. Look along the top of the cell, 
with the short still in place. If there is a small arc 
between the cell top and copper contact, then that is 
the bad contact. Pull cell out and gently pull the 
copper contact down. 

6.  If an arc is not seen and there is a bad contact, then 

the problem may be an internal contact in one of the 
cells.  

7.  Let up on safety interlock. 
8.  Close access door. 

See below for additional testing. 

Testing Cell with an Ohmmeter

 

To test the cell for a dead short or a bad contact an 

ohmmeter can be used. 

Always discharge the cell with 

a screw driver before testing with an ohmmeter. 

Model 

Max. Voltage on 

Plates (KVDC) 

Max. Voltage on 

Ionizer (KVDC) 

GSASD-12, GSASD-18 

4.8 - 5.2 (HV1) 

7.2 - 7.8 (HV2) 

GSASD-10, GSASD-11 

4.8 - 5.3 (HV1) 

7.2 - 8.0 (HV2) 

Table 3 — Power Board Voltage Settings (with load) 

The voltage will be higher without the cells in the unit.

 

Содержание ASASD-10

Страница 1: ...ruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filters remove unple...

Страница 2: ...of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 re...

Страница 3: ...oss the Air Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fa...

Страница 4: ...pe humidifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Wh...

Страница 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applica...

Страница 6: ...non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and DAX...

Страница 7: ...from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells ins...

Страница 8: ...oard is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor i...

Страница 9: ...voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high voltage If one is not...

Страница 10: ...ve it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Repl...

Страница 11: ...09 D0 0509 D1 0509 11 Power Box Complete No Cover 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0...

Страница 12: ...vely power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry completely Particles lodged in cell or broken ionizing wire Wash cell Shake particle out of c...

Страница 13: ...basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below to...

Страница 14: ...NOTES 14...

Отзывы: