Note:  

There may be some arcing or snapping sounds 

from the collecting cells. This is normal when the unit is 
new. In about 2 weeks, as the sharp edges of the cells 
become smoother, the arcing will disappear. 

 

OPERATION 

The Air Cleaner will run as long as there is adequate 

airflow through the ducts. The Air Cleaner will not run if 
the system fan is off. For proper operation, follow these 
simple steps: 
1.  Run heating/cooling system fan continuously, and on 

low speed if available. 

2.  Remove furniture or carpets which block return air 

grilles throughout your house, so that air moves 
freely to the furnace/ air conditioner. 

3.  Check for proper operation of the system fan. 

 

WHITE DUST 

After installation of the Air Cleaner, you may notice 

some white dust on tabletops and shelves. Most large 
particles such as lint, are too heavy to remain airborne 
and tend to settle quickly, never reaching the air cleaner. 

This white visible dust is normally referred to as 

“clean dust.” As the Air Cleaner is removing the dark and 
staining particles from the air, the lint will also be cleaner. 

Lint dust is most noticeable on dark furnishings; in 

homes containing new carpeting; and where there is a lot 
of household traffic from occupants and pets. To reduce 
lint dust, use continuous fan operation and keep return 
vents unrestricted to create an efficient airflow. 

Note:  

The Air Cleaner does NOT produce more lint or 

dust.

 

MAINTENANCE 

It is important to follow a scheduled maintenance for 
maximum performance of the Air Cleaner. 

Cell And Prefilter Cleaning 

The collecting cells and prefilters must be cleaned on a 
regular basis for the Air Cleaner to function at its peak of  
efficiency. The frequency of cleaning will vary from one 
house to another. On average, the cells should be 
cleaned every 3 months. 
1.  Remove access door, collecting cells and prefilters. 
2.  Place cells in a laundry tub. Rinse with hot water and 

spray completely with DAX Detergent (or a non-
chlorine, non-corrosive, non-abrasive liquid 
household detergent. Allow detergent to run down 
both sides of plates and ionizing wires. Let stand for 
5 minutes or fill up laundry tub with water and DAX 
Detergent, and dunk cells up and down until water is 
dirty. 

3.  Rinse cells well with hot water (maximum 120°F/49°

C). 

4.  To remove contaminate from the ionizing wires use 

an old toothbrush. Slide the brush bristles over the 
wire and gently drag the brush up and down the wire 
once. Be very careful when cleaning the wires as 
they become very brittle with age. 

5.  If dirt remains on the cell plates, let the cells soak in a 

solution of DAX Detergent and water for 30 minutes. 

6.  Tilt cells on 45° angle on their short side, with arrows 

pointing sideways. Allow to dry completely, 
approximately 12-24 hours. A hair dryer may be used 
to speed up drying time. 

7.  To wash prefilters, spray with DAX Detergent, rinse 

and let dry. Do not wash in the same water as 
collecting cells. 

8. 

Do not place the cells in the air cleaner if they are 
wet.

 

9.  Place cells and prefilters back into cabinet. Close 

door and turn power switch ON. If the performance 
light does not come on or arcing occurs, turn Air 
Cleaner OFF and allow air from system fan to dry 
cells completely. 

Activated Carbon Filter Replacement 

Carbon filters help remove odors from the air. If the 

Air Cleaner has been equipped with carbon filters, they 
should be replaced every 3 - 6 months. Filters are NOT 
washable. Replacements are available through your 

CAUTION  

Make sure to turn Air Cleaner and system fan 

OFF 

before performing any maintenance or removing any 
components.  

CAUTION  

Damage to cells may occur if improperly handled or 
washed. Do not wash cells in a dishwasher. Never use 
any object to clean between the cell plates, as this may 
cause damage to plates or ionizing wires. Never place 
cell in oven to dry. The edges of the cell may be sharp - 
handle with care.  

 

Replacement Carbon Filters: 

GSASD-10, GSASD-11       Set of 3       Part #1156-3 
GSASD-12, GSASD-18       Set of 3       Part #1856-3 

Fig. 6 — DAX Detergent and Carbon Filters are 
available from your installer or dealer. 

DAX 

 

32 oz Spray Bottle 

Part #FS9900 

Содержание ASASD-10

Страница 1: ...ruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filters remove unple...

Страница 2: ...of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 re...

Страница 3: ...oss the Air Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fa...

Страница 4: ...pe humidifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Wh...

Страница 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applica...

Страница 6: ...non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and DAX...

Страница 7: ...from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells ins...

Страница 8: ...oard is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor i...

Страница 9: ...voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high voltage If one is not...

Страница 10: ...ve it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Repl...

Страница 11: ...09 D0 0509 D1 0509 11 Power Box Complete No Cover 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0...

Страница 12: ...vely power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry completely Particles lodged in cell or broken ionizing wire Wash cell Shake particle out of c...

Страница 13: ...basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below to...

Страница 14: ...NOTES 14...

Отзывы: