Good Earth Lighting G9112-SSX-I Скачать руководство пользователя страница 2

Preparation

Mounting Instructions

english

1

WARNING: 

Shut off power at the circuit breaker or fuse panel before removing the old fixture.

Your Good Earth Lighting® xenon under cabinet light is the perfect lighting solution for 

kitchens, bathrooms, bookcases, entertainment centers, and study areas. We recommend you 

read through the instructions entirely before starting your installation in order to help you 

understand all the steps and options regarding your particular installation.

IMPORTANT SAFETY INSTRUCTIONS

This unit has a polarized plug (one blade is wider than the other) as a safety feature. This plug 

will fit in a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the 

plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord 

unless the plug can be fully inserted. Do 

NOT

 attempt to defeat this feature.

SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO YOUR LIGHT FIXTURE SO YOU CAN 

REFER TO THEM AT A LATER TIME.

  1. Turn off/unplug and allow to cool before replacing the bulb (lamp).

  2. Bulb (lamp) gets 

HOT

 quickly! Use caution when turning 

ON

 and 

OFF

.

  3. Do 

NOT

 touch hot lens, guard, or enclosure.

  4. Do 

NOT

 remain in light if skin feels warm.

  5. Do 

NOT

 look directly at lighted bulb (lamp).

  6. Keep away from materials that may burn, or melt.

  7. Use with a

 120V/G8 base bulb/20 watt or smaller

.

  8. Do 

NOT

 operate the unit with a missing or damaged guard or lamp containment barrier.

  9. Use only insulated staples or plastic ties to secure the cords.

  10. Route and secure the cord so that it will not be pinched or damaged when cabinet is    

    pushed to the wall.

  11. Do 

NOT

 use an extension cord. Use a power strip with integral overcurrent protection to

       supply other electrical devices or accessories in cabinet.

  12. Keep cord or combustibles such as plastic, paper goods, and the like away from hot    

    lamp, lampholder, or reflector.

  13. Position cabinet light with respect to cabinet so as to permit reading of the lamp  

 

    replacement markings during relamping.

  14. Not intended for illumination of aquariums.

  15. Not intended for installation in plastic cabinets.

  16. Not intended for recessed installation in ceilings, or soffits.

  17. Do not conceal power cord inside a wall, ceiling, soffit, kitchen cabinet, or similar  

 

    permanent structure.

  18. Do 

NOT

 attempt to install while plugged in.

  19. For

 INDOOR USE ONLY

.

  20. Do 

NOT

 mount the xenon lights to cabinets having a material thickness less than 1/4 in.

  21. Do 

NOT

 install these lights inside of enclosed cabinets.

  22. Do 

NOT

 mount over sinks or stoves.

DO NOT INSTALL THE FIXTURE WHILE IT IS PLUGGED INTO AN ELECTRICAL OUTLET! FOR 

INDOOR INSTALLATIONS ONLY. DO NOT INSTALL OVER SINKS, OR STOVES.    

To make installation easier, a template has been included on the back insert card of the 

package (the card with the UPC code on it). The template provides the center-to-center 

distance where the mounting screws should be located. Cut along the dashed line, 

position and tape the template to the surface where the fixture is to be installed. Drill a 

small diameter hole where the lines cross to make a “+” in the center of each circle on 

the template. Remove the template from the mounting surface. 

NOTE:

 Be sure to allow 

enough space for the fixture to fit and be plugged-in.

Bulb Replacement Instructions

1

2

3

4

Replace with 120V, Type G8 base xenon bulbs, 20 Watt maximum.

Place the two small rubber grommets over the mounting screws (

Fig. 1

). 

Screw in the two #8 mounting screws until the rubber 

grommets contact the bottom surface of the 

cabinet (

Fig. 2

). Then turn the screws another 1/4 

turn. The screws must be driven in straight for the 

light bar to mount properly.

Fig. 1

Fig. 2

Align the key hole slots on the bottom plate of the light bar 

over the mounting screws and firmly slide the light bar 

over in one direction to lock it into place (

Fig. 3

). The light 

bar can slide toward the front, rear or from side to side 

depending on the spacing in your particular installation. 

The light bar should fit tightly up against the mounting 

surface. If not, then your screws need to be tightened a little more for an improved fit. 

Fig. 3

Fig. 4

Turn the light bar off and allow sufficient time for the unit and bulb (lamp) to cool 

properly before handling.

Once the light bar is in place, route your power cord to the 

closest outlet. Your xenon light bar has a three position 

rocker switch on the face of the unit. The center position is 

the '

OFF

' position. The other two positions offer you a '

HIGH

or '

LOW

' light level setting depending on your needs (

Fig. 4

).

- 2 -

Содержание G9112-SSX-I

Страница 1: ...ede variar de la que se muestra en la ilustraci n Installation Time 45 Minutes Dur e de l installation 45 minutes Tiempo de instalaci n 45 minutos Required Requis Se necesitan Hardware Kit Kit de viss...

Страница 2: ...n ceilings or soffits 17 Do not conceal power cord inside a wall ceiling soffit kitchen cabinet or similar permanent structure 18 Do NOT attempt to install while plugged in 19 For INDOOR USE ONLY 20 D...

Страница 3: ...intenez une distance suffisante d objets risquant de br ler ou de fondre 7 Utilisez avec une ampoule de 120 volts 20 watts base G8 ou moins 8 N utilisez PAS ce luminaire si le dispositif de protection...

Страница 4: ...tage REMARQUE Assurez vous de pr voir suffisamment d espace afin de pouvoir placer le luminaire et le brancher Instructions de remplacement de ampoules 1 Remplacez les ampoules par des ampoules x non...

Страница 5: ...ministrar electricidad otros dispositivos o accesorios el ctricos que est n en el gabinete 12 Mantenga el cable o las cosas combustibles tales como pl stico productos de papel y cosas similares alejad...

Страница 6: ...de luces sobre los tornillos de montaje y deslice firmemente por encima la barra de luces en una direcci n para fijara en su sitio Fig 3 La barra de luces se puede deslizar hacia la parte delantera la...

Страница 7: ...ten help get the problem corrected right over the phone You can call us at 1 800 291 8838 9AM 5PM CST Monday through Friday In the unlikely event the Good Earth Lighting fixture fails to perform as it...

Страница 8: ...els ou autres ou IV sont directement ou indirectement en rapport avec la vente l utilisation ou la r paration du produit Good Earth Lighting Inc 5260 Capitol Drive Wheeling IL 60090 GARANT A LIMITADA...

Отзывы: