110
109
ush buttons wiring.
P
DOOR PANEL INSTALLATION
DOOR PANEL INSTALLATION
lace the nameplate labels.
P
Open the label holder.
Place the label and
close.
Plug the push buttons connection cable to the CN6 connector
of the EL500SE microprocessor circuit, this cable has 10
conductors (P1 to P8, B and CP) for the connection of push
buttons or EL516SE.
The CP terminal must be connected to the push buttons
common terminal and to the CP terminal of the push
buttons encoder circuits. Connect B terminal to the B
terminal of the encoders.
Link the push button inputs (P1...P8) to the push buttons
and/or to the encoder circuits (P) as shown in the example.
EL-516SE
B
CP
P
CN1
CN6
EL516SE
Description CN2 conector
1
2
3
4
9
10
11
12
13
14
15
5
6
7
8
CN2
CN3
CP: Black
B:
Red
P9:
Green
P10: Orange
P11: Blue
P12: Violet
P13: Yellow
P14: White
P15: Brown
: Grey ( )
EL516SE
Description CN3 conector
**
P5
P6
P7
P8
P4
P3
B
o
hr
n
o
e
r
u
bt
n
To
t
e
e
c
d
rs
op
sh
u
to
s
CP
P2
IMPORTANTE:
In case of more than one access, wire all the push buttons and modules EL-516SE
following the same order in all the door panels.
CP
P8
B
P7
P1
P6
P2
P5
P3
P4
Top view
CP: Black
B:
Red
P1:
Green
P2:
Orange
P3:
Blue
P4:
Violet
P5:
Yellow
P6:
White
P7:
Brown
P8:
Grey
Colours codes
CP
P8
B
P7
P1
P6
P2
P5
P3
P4
Top view
CP: Black
B:
Red
P1:
Green
P2:
Orange
P3:
Blue
P4:
Violet
P5:
Yellow
P6:
White
P7:
Brown
P8:
Grey
Colours codes
CP B
P15
P9
P14
P10
P13
P11
P12
Top view
Colours codes
EL500SE
Description CN6 conector
( )
No function.
**
ush buttons wiring.
P
For a quality finish, pass the push buttons wires through the
spacer hole of the closest module. It's recommended to
2
use wires of less than 0,25mm section.
Twist the call wires as shown. The call wires will be
connected to the EL500SE microprocessed circuit or
to the corresponding EL516SE push buttons encoder.
IMPORTANT: link the push buttons common terminal of the
several push buttons modules. The common terminal of
the push buttons contained in a module are linked from
factory. The CP terminal of the EL500SE microprocessed
circuit must be connected at the push buttons common
and to the CP terminal of the corresponding EL516SE
encoder circuit (if it exists).