background image

118

117

amps wiring.

L

DOOR PANEL INSTALLATION

LOCK RELEASE INSTALLATION

nstalling the FA-PLUS and FA-PLUS/C power supplies.

I

DIN 46277

f

3,5 x 25

DIN-7971

f

3,5 x 25

DIN-7971

M 4 x 8

f

3,5 x 25

 DIN-7972 

 DIN-963

POWER SUPPLY INSTALLATION

ock release installation.

L

inal adjustments.

F

lose the door panel.

C

Fix the door panel by using the supplied
     screws.

Finish the door panel assembly by pressing
     the closing heads.

Once the nameplate labels are placed, wire the lamps from different 

modules and connect them to terminals L1 and L2 of the sound 
module.

If the number of door panel lamps is higher than eight, connect a TF-

104 transformer between ~1 and ~2 terminals of the sound 
module and change JP2 jumper position.

NOTE: Don't change JP1 jumper position. JP1 and JP2 jumpers are placed on the left side of the 

sound module terminal connector.
If the TF-104 transformer with alternating current lock release is also used, wire ~1/~2
terminals of the sound with CV1/CV2 terminals respectively of the EL500SE module.

Replace the protection cover once the input terminals have been wired.

If after starting the system it's considered that the audio 

volume isn't correct, proceed with the necessary 
adjustments as shown.

The telecamera has a pan and tilt mechanism built in to adjust 

the telecamera position.

In case of low light conditions, an external illumination can be 

activated by connecting a SAR-12/24 relay between 
terminals '+H' and 'L2' of the sound module.

The power supply must be installed in a dry and 

protected place. It's recommended to protect the 
power supply by using a thermo-magnetic circuit 
breaker. Use a ground connection with FA-Plus
power supply.

To install the power supply directly on the wall, drill two holes of 

Ø6mm. and insert the wallplugs. Fix the transformer with the 
specified screws.

The power supply can be installed on a DIN 46277 

guide simply pressing it.

To disassemble the power supply from the DIN guide, 

use a plain screwdriver to lever the flange as shown 
on the picture.

The FA-Plus/C model uses 6 units over DIN guide and 

10 units the FA-Plus model.

IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power supply is 

10, and 50 units in case of a FA-Plus model. Link power supplies to connect more 
units than the specified as it's shown on page 132.

If the lock release will be installed in a metal door, use a Ø3,5mm.

drill and tap the hole. In case of wood door, use a Ø3mm. drill.

IMPORTANT: the lock release must be of 12Vd.c. or a.c.

See page 132 (a.c. lock releases) and page 133 - 144 (d.c lock releases)

Содержание Stadio Plus T500SE ML

Страница 1: ...En cas d effet Larsen r duire le volume jusqu disparition de celui ci Si l effet Larsen dispara t seulement lorsque le volume est au minimum il est possible qu il y ait un autre probl me O Effet Larse...

Страница 2: ...installation wVideo door entry system with 3 common wires plus coaxial cable installation wVideo door entry system with 4 common wires plus twisted pair installation O Microprocessed circuit EL500SE...

Страница 3: ...the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset O Th...

Страница 4: ...s been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry...

Страница 5: ...rcuit in the bottom flanges 2 by pressing the pcb board To assembly the EL516SE encoder screw the top tab of the case to the corresponding plastic lug of the embedding box In case of more than one enc...

Страница 6: ...han one access wire all the push buttons and modules EL 516SE following the same order in all the door panels CP P8 B P7 P1 P6 P2 P5 P3 P4 Top view CP Black B Red P1 Green P2 Orange P3 Blue P4 Violet...

Страница 7: ...o OFF coaxial cable RG 59 o RG 11 Set to ON twisted pair Selects if the door panel has telecamera or not In case of door panels without telecamera EL540 sound module set to ON Plus system loads the in...

Страница 8: ...bone building Set a code between 1 and 120 for inner backbones up to 127 with coded panel and a code 0 for general door panel s To set the code use binary coding as shown on the next paragraph Factory...

Страница 9: ...ry coding see page 113 nformative window connection I DOOR PANEL INSTALLATION The EL500SE microprocessor module supplies a cable with conector for the indication of busy system Insert the side of the...

Страница 10: ...th the necessary adjustments as shown The telecamera has a pan and tilt mechanism built in to adjust the telecamera position In case of low light conditions an external illumination can be activated b...

Страница 11: ...the activation of an optional second camera If not allows to make an intercom call or to activate the second camera If the handset is on the craddle allows the activation of an optional device If not...

Страница 12: ...hanging the front film C MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION Locate the CN4 connector that s placed in the monitor base Remove the existing jumper and plug the EL562 module NOTE on this...

Страница 13: ...s the monitor firmly To disassemble the monitor from the connector use a plain screwdriver to release the attachment clip Remove the monitor from the connector with special attention do not falls Swit...

Страница 14: ...intercom call when the handset is not on the craddle This function is described on page 147 If the handset is on the craddle sends a panic call to the porter s exchanges that have enabled the receptio...

Страница 15: ...e right front of the telephone To show that the system is ready for programming the door panel will reproduce a tone and the telephone led will blink At this moment the door release push button can be...

Страница 16: ...one of the following functions Autoswitch on PA output call to a slave porter s exchange and intercommunication escripci n del microinterruptor de configuraci n D escription of programming push butto...

Страница 17: ...lose the telephone P3 ON P3 SW1 Open the telephone to programming see page 130 Select in the SW1 dip switch the fuction mode for the auxiliary see page 129 and later press the P3 programming push butt...

Страница 18: ...ut Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230110 0 SW2 SW2 Core max electrical resistence to 20 C Copper core Copper shield E...

Страница 19: ...alla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW2 SW2 ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS Place this power supply as closest as possible to the first distributor S M Access door pa...

Страница 20: ...Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SEC PRI ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS S M Access door panel Access door panel The installation diagra...

Страница 21: ...in Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 FA...

Страница 22: ...To install and configure properly d The installation diagram shows the connection of a video system with two general door panels and up to 120 inner door panels backbones buildings In case of more tha...

Страница 23: ...D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 General door panel SW2 SW1 IMPORTANT NOTES To install and configure properly d The installation diagram...

Страница 24: ...e 120 This facility disables the intercom function If both functions are required use A1 terminal to activate the second camera To activate this function press monitor push button at any moment with n...

Страница 25: ...m facility between two units of the same apartment To enable this function check the following conditions One of the units has been configurated as master and the other unit as slave with intercom as...

Страница 26: ...fade out If feedback don t dissapears refer to the following hint O Continuous audio feedback w Check that A terminal is not shortcircuited with other terminals O Door open function no operates w Rem...

Отзывы: