GENERAL DOOR PANEL INSTALLATION

Define a backbone code to program with dip switches Sw2-4 to Sw2-

10. Set a code between 1 and 120. To set the code use binary
coding, (see page 113).

Press the general door panel push button that is wished has this 

backbone code. At this moment the general door panel will 
reproduce a tone, confirming that the push button has been 
succesfully programmed.

Repeat these steps to program the rest of push buttons. Once the programming has been finished, 

set to OFF the programming switch. If you don't, the general door panel will reproduce a tone to 
advise that the system is still into programming mode.

Programming the push button (with a monitor/telephone code):

This programming mode allows to assign a monitor/telephone code to push button of the general

door panel.

Locate the SW2 configuration dip switch of the general door

panel to program, placed in the center of the EL500SE circuit.
With the switches 1 and 3 to ON, set the switch 2 to ON: to
show that the system is ready for programming, the general
door panel will reproduce a tone.

Press the general door panel push button that is wished has this 

monitor/telephone code. At this moment the general door 
panel will reproduce a tone, confirming that the push button 
has been succesfully programmed.

Repeat these steps to program the rest of push buttons. Once the programming has been finished, 

set to OFF the programming switch. If you don't, the general door panel will reproduce a tone to 
advise that the system is still into programming mode.

Define a monitor/telephone code to program with dip switches Sw2-4

to Sw2-10. Set a code between 1 and 120. To set the code use
binary coding, (see page 113).

nformative window connection.

I

DOOR PANEL INSTALLATION

The EL500SE microprocessor module supplies a cable with conector 

for the indication of busy system.
Insert the side of the cable that takes the connector in the connector 
CN3 of the EL500SE microprocessor module. It is accessed by 
opening the terminal connection block protection cover.

Connect the red cable to the terminal 1 of the informative window 

circuit and the white cable to the terminal 2 (if the informative 
window exists).

This programming mode allows to assign to a monitor / telephone a push button of the general door 

panel that it wishes to call.

Before the push button of the general door panel must be programmed with backbone and 

monitor/telephone code, (see page 115).

Programación del monitor/teléfono:

Locate the SW2 configuration dip switch of the general door

panel to program, placed in the center of the EL500SE circuit.
With the switch 1 to OFF and 3 to ON, set the switch 2 to ON:
to show that the system is ready for programming, the general
door panel will reproduce a tone.

Then program the monitor/telephone, as it is described in the page 124 (monitor), 127 and 131 

(telephone), (see manual T1ML if the monitor/telephone is Platea Uno or T-940 Uno).

Bear in mind the configuration dip switch (as it is described in the previous step).

rogramación de los monitores y teléfonos desde una Placa General.

P

GENERAL DOOR PANEL INSTALLATION

Programming the push button (

):

with a backbone code

This programming mode allows to assign a backbone code to push button of the general door panel.

Locate the SW2 configuration dip switch of the general door

panel to program, placed in the center of the EL500SE circuit.
With the switch 1 to ON and 3 to OFF, set the switch 2 to ON:
to show that the system is ready for programming, the general
door panel will reproduce a tone.

115

116

Содержание Stadio Plus T500SE ML

Страница 1: ...En cas d effet Larsen r duire le volume jusqu disparition de celui ci Si l effet Larsen dispara t seulement lorsque le volume est au minimum il est possible qu il y ait un autre probl me O Effet Larse...

Страница 2: ...installation wVideo door entry system with 3 common wires plus coaxial cable installation wVideo door entry system with 4 common wires plus twisted pair installation O Microprocessed circuit EL500SE...

Страница 3: ...the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset O Th...

Страница 4: ...s been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry...

Страница 5: ...rcuit in the bottom flanges 2 by pressing the pcb board To assembly the EL516SE encoder screw the top tab of the case to the corresponding plastic lug of the embedding box In case of more than one enc...

Страница 6: ...han one access wire all the push buttons and modules EL 516SE following the same order in all the door panels CP P8 B P7 P1 P6 P2 P5 P3 P4 Top view CP Black B Red P1 Green P2 Orange P3 Blue P4 Violet...

Страница 7: ...o OFF coaxial cable RG 59 o RG 11 Set to ON twisted pair Selects if the door panel has telecamera or not In case of door panels without telecamera EL540 sound module set to ON Plus system loads the in...

Страница 8: ...bone building Set a code between 1 and 120 for inner backbones up to 127 with coded panel and a code 0 for general door panel s To set the code use binary coding as shown on the next paragraph Factory...

Страница 9: ...ry coding see page 113 nformative window connection I DOOR PANEL INSTALLATION The EL500SE microprocessor module supplies a cable with conector for the indication of busy system Insert the side of the...

Страница 10: ...th the necessary adjustments as shown The telecamera has a pan and tilt mechanism built in to adjust the telecamera position In case of low light conditions an external illumination can be activated b...

Страница 11: ...the activation of an optional second camera If not allows to make an intercom call or to activate the second camera If the handset is on the craddle allows the activation of an optional device If not...

Страница 12: ...hanging the front film C MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION Locate the CN4 connector that s placed in the monitor base Remove the existing jumper and plug the EL562 module NOTE on this...

Страница 13: ...s the monitor firmly To disassemble the monitor from the connector use a plain screwdriver to release the attachment clip Remove the monitor from the connector with special attention do not falls Swit...

Страница 14: ...intercom call when the handset is not on the craddle This function is described on page 147 If the handset is on the craddle sends a panic call to the porter s exchanges that have enabled the receptio...

Страница 15: ...e right front of the telephone To show that the system is ready for programming the door panel will reproduce a tone and the telephone led will blink At this moment the door release push button can be...

Страница 16: ...one of the following functions Autoswitch on PA output call to a slave porter s exchange and intercommunication escripci n del microinterruptor de configuraci n D escription of programming push butto...

Страница 17: ...lose the telephone P3 ON P3 SW1 Open the telephone to programming see page 130 Select in the SW1 dip switch the fuction mode for the auxiliary see page 129 and later press the P3 programming push butt...

Страница 18: ...ut Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230110 0 SW2 SW2 Core max electrical resistence to 20 C Copper core Copper shield E...

Страница 19: ...alla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW2 SW2 ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS Place this power supply as closest as possible to the first distributor S M Access door pa...

Страница 20: ...Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SEC PRI ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS S M Access door panel Access door panel The installation diagra...

Страница 21: ...in Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 FA...

Страница 22: ...To install and configure properly d The installation diagram shows the connection of a video system with two general door panels and up to 120 inner door panels backbones buildings In case of more tha...

Страница 23: ...D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 General door panel SW2 SW1 IMPORTANT NOTES To install and configure properly d The installation diagram...

Страница 24: ...e 120 This facility disables the intercom function If both functions are required use A1 terminal to activate the second camera To activate this function press monitor push button at any moment with n...

Страница 25: ...m facility between two units of the same apartment To enable this function check the following conditions One of the units has been configurated as master and the other unit as slave with intercom as...

Страница 26: ...fade out If feedback don t dissapears refer to the following hint O Continuous audio feedback w Check that A terminal is not shortcircuited with other terminals O Door open function no operates w Rem...

Отзывы: