background image

74

73

SYSTEM CHARACTERISTICS

SYSTEM OPERATION

INTRODUCTION

STARTING RECOMMENDATIONS

INDEX

First  of  all  we  would  like  to  thank  and  congratulate  you  for  the  purchase  of  this  product 

manufactured by Golmar.

The commitment to reach the satisfaction of our customers is stated through the ISO-9001 

certification and for the manufacturing of products like this one.

Its advanced technology and exacting quality control will do that customers and users enjoy with 

the legion of features this system offers. To obtain the maximum profit of these features and a properly 
wired installation, we kindly recommend you to expend a few minutes of your time to read this manual.

O

Do not use excessive force when tightening the power supply connector screws.

O

Install the equipment without the power connected. Disconnect from power before any system 
modification. Check that the input voltage is lower than 230Va.c.

O

Before to connect the system, check the connections between door panel, monitors  and 
telephones, and the transformer connection. Do always follow the enclosed information.

O

Each time the power supply is restarted, or after a modification, the system will remain blocked 
during 30 seconds.

O

Always use RG-59 or RG-11 coaxial cables. 

Never use coaxial antenna cable.

 In 

installations no longers than 100m., 

Golmar RAP-5130

 cable can be used.

O

To make a call the visitor should press the push button corresponding to the apartment he wishes 
to contact. An acoustic tone will be heard confirming the call is in progress once the push button 
has been pressed. At this moment the call will be received at the monitor (telephone) in the 
dwelling. During the call the visitor can correct his call by pressing a push button corresponding 
to a different apartment, in which case the original call is cancelled.

O

In systems with several access doors, the other(s) door panel(s) will be automatically 
disconnected: if a visitor tries to call from other door panel an acoustic tone will be heard 
confirming the system is busy.

O

The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will 
appear on the master monitor without the visitor being aware of this. To see the picture in a slave 
monitor press the     push button, dissapearing the picture on the other monitor. If the call is not 
answered in 45 seconds, the system will be freed.

O

To establish communication pick up the monitor (telephone) handset. The communication will last 
for one and a half minutes or until the handset is replaced. Once the communication has finished 
the system will be freed.

O

To open the door, press the door release push button during call or communication progresses: 
with one press, the door release operates during 3 seconds. During the lock release activation an 
acoustic tone will be heard on the door panel confirming the lock release is activated.

O

The monitor and telephone push buttons description is shown on pages 88 and 93 respectively.

O

Microprocessed system with 3 common wires plus coaxial cable installation or 4 common wires 
plus twisted pair (only for kits /SC).

O

Fully compatible with 'Stadio' audio systems of 4 common wires installation.

O

Unlimited number of door panels being not necessary the use of switching units.

O

Acoustic busy channel and call acknowledgement signals.

O

d.c. lock releases activation.

O

Timed door open activation.

O

In Platea Plus monitors or T-940 Plus telephones:

w

Privacy on audio and video communications.

w

'Video-Spy' function remaining the communication channel free.

w

Intercommunication function with other monitor or telephone of the same apartment.

w

Input for door bell apartment push button.

w

Different call reception tones depending where the call is comming from: main or slave door 

panels, door bell push button, intercom, ...

w

Activation of two auxiliary devices: secondary telecamera, courtesy light, ...

w

Up to three monitors or telephones in the same apartment without additional power supplies.

Introduction........................................73
Index .................................................73
Starting recommendations ...................73
System characteristics ..........................74
System operation ................................74
Door panel installation ............................

Description ......................................75
Embedding box positioning ......76 to 77
Door panel modules assembly...........77
Electronic modules assembly .............78
Door panel fixing..............................79
Push buttons wiring ..................80 to 81
Push buttons coding..........................82
EL500 configuration ................83 to 84
EL560 optional module.....................84
Lamps wiring....................................85
Final adjustments..............................85

Power supply installation......................86
Lock release installation.......................86
Platea Plus monitor .................................

Description ......................................87
Function push buttons .......................88
EL562 module .................................89

End of line resistor ............................89
Front film replacement ......................89
Monitor connector description ...........90
Monitor installation...........................91
Programming ...................................92

T-940 Plus telephone ..............................

Description ......................................93
Function push buttons .......................93
Telephone installation .......................94
Programming ...................................95

Installation diagrams ...............................

Connection of an a.c. lock release.....96
Link of several power supplies............96
Video installation with coaxial ...97 to 98
Video installation without coaxial99 to 100
Audio installation.................101 to 102

Optional connections..............................

External lock release activation ........103
Auxiliary devices activation ..............103
Intercom function ...........................104
TV connection ................................104
2nd camera activation ....................105
Door bell push button connection ....105

Troubleshooting hints ........................106

Содержание Stadio Plus T500ML

Страница 1: ...71 Stadio Plus Instructions manual Audio and Video door entry system digital installation T500ML rev 0205 ...

Страница 2: ...half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication progresses with one press the door release operates during 3 seconds During the lock release activation an acoustic tone will be heard on the door panel confirming the lock release is activated O The monitor an...

Страница 3: ...f the door panel should be placed at 1 65m height roughly The hole dimensions will depend on the number of door panel modules The door panel has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry systems avoid direct incidence from light sources reparin...

Страница 4: ...N marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the module by screwing the shafts Repeat this procedure in case of door panels with one more module the maximum number of modules placed vertically is three Insert the header UP marked in the last module an...

Страница 5: ...el on the embedding box insert the hinges in the embedding box lockers as shown old the door panel on the embedding box H For a quality finish pass the push buttons wires through the spacer hole of the closest module 2 It s recommended to use wires of less than 0 25mm section IMPORTANT link the push buttons common terminal of the several push buttons modules The common terminal of the push buttons...

Страница 6: ...6 circuits With 5 EL516 circuits With 6 EL516 circuits With 7 EL516 circuits With 8 EL516 circuits 8 7 15 22 6 15 15 36 5 15 15 15 50 4 15 15 15 15 64 3 15 15 15 15 15 78 2 15 15 15 15 15 15 92 1 15 15 15 15 15 15 15 106 0 15 15 15 15 15 15 15 15 120 To other encoders or push buttons 1 P2 1 P1 31 P4 61 P6 91 P8 16 P3 46 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 ...

Страница 7: ... installations the EL562 module must be plugged in all the monitors and JP2 jumper of the EL500 circuit must be placed on the position specified on page 83 Refer to the specific installation diagram escription of the configuration dip switch D Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is finished return the switch to OFF position The programm...

Страница 8: ...case of a FA Plus model IMPORTANT Link power supplies to connect more units than the specified as it s shown IMPORTANT on page 96 IMPORTANT The power supply must be installed in a dry and protected place It s recommended to protect the power supply by using a thermo magnetic circuit breaker and to use a ground connection ock release installation L inal adjustments F lose the door panel C Fix the d...

Страница 9: ... Floor Door Stair PLATEA Plus 0000000000 Nº serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment holes Identification label Connecting points CN4 connector Three positions call reception volume control Cable slot Contrast control color control in case of color screen Brightness control Monitor ...

Страница 10: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L562 module for video installations E with twisted pair cable andling the end of line jumper H hanging the front film C The end of line jumper is placed on the CN4 connector that can be located on the monitor base In case of twisted pair cable installations the end of line jumper is placed in the E...

Страница 11: ...de In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release push button With the door release push button pressed switch on the monitor To show that the system is ready for programming the door panel will reproduce a sound and the picture will appears on the mo...

Страница 12: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description T positive ground audio digital communication intercom auxiliary calling device output door bell push button input A D INT SA HZ A D _ SA INT HZ TELEPHONE INSTALLATION ix the telephone F It will be necessary to open the telep...

Страница 13: ...slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set to OFF the programming switch If you don t the door panel will reproduce a sound to advise that the system is still into programming mode M R B O T R 3 TF 104 SEC CV CV D Malla Vin Ain Aout Vin Vou...

Страница 14: ...istributor INSTALLATION DIAGRAMS ideo installation with coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels w...

Страница 15: ... Terminal SECTIONS CHART 50m Distance 150m A A A D in out V V V M in out p d p d CV CV INSTALLATION DIAGRAMS ideo installation without coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire ...

Страница 16: ... A 1 00mm 2 50mm 0 25mm 0 25mm Terminal SECTIONS CHART 50m Distance 150m A A A D in out CV CV Place this power supply as closest as possible to the first telephone The installation diagram shows the connection of an audio system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one do...

Страница 17: ...ART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17 shield and 20 hot of the SCART connector ntercom function I Platea Plus monitor and T 940 Plus telephone have intercom facility between two units of the same apartment To enable this function check...

Страница 18: ...nits with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c If not disconnect the power supply from the installation and measure again If it s correct now it means there is a short circuit in the installation disconnect the power supply from mains and chec...

Отзывы: