background image

104

103

SA

+

T

T

R

R

M

M

SAR-90

SA

+

T

T

R

R

M

M

SAR-90

TF-104

SEC

~

~

CV+

CV-

-

A

+ _

D INT

A

_

+

D

A1

Malla

V

in

V

out

CN4

A

_

+

D

A1

Malla

V

in

V

out

CN4

A

_

+

D

INT

Malla

V

in

V

out

CN4

A

_

+

D

Malla

V

in

V

out

CN4

OPTIONAL CONNECTIONS

OPTIONAL CONNECTIONS

The lock release can be activated at any moment
     by using an external push button, that must be
     connected between 'CV ' y ' ' terminals of the

     EL500 circuit. This function will allows to exit from
     the building being not necessary the use of a key.

xternal lock release activation.

E

uxiliary devices activation.

A

To activate auxiliary devices the use of a SAR-90 relay unit will be required. If this device is
     shared for all the monitors, link their A1 terminal and use just one relay unit.
     In case that each monitor has its own application use a SAR-90 relay unit for each monitor
     and don't link the A1 monitor terminals.
To activate this function, press 

 

 monitor push button at any moment with no dependence of

     the handset position.
Usual applications are the activation of stairs light, second lock release, ...

The use of a TF-104 transformer will be necessary to activate a second lock release.
IMPORTANT: the lock release must be 12Vc.a. type.

To stairs light push button

onnecting the Shiner Plus monitor 

C

to a video recorder or TV.

If your TV or video recorder have a SCART
     connector, it will be possible to view
     the picture from the door panel on the TV
     screen.
Remove the end of line jumper, that's placed on the
     CN4 connector. Connect the coaxial cable
     between terminals 17 (shield) and 20 (hot)
     of the SCART connector.

ntercom function.

I

Platea Plus monitor and T-940 Plus telephone have intercom facility between two units of the
     same apartment

. To enable this function check the following conditions:

          - One of the units has been configurated as master and the other unit as slave with
               intercom, as described on pages 92 and 95.
               In case to intercom one monitor with one telephone, configure the monitor as master..
          - Link the INT terminal of the units, as it is shown on the enclosed diagram.

To establish an intercom communication lift the handset and press the intercom push button;
     acoustic tones will be reproduced on the handset confirming the call is in progress or
     that the other unit is communicating with the door panel. To establish communication lift
     the handset of the called unit

. If during an intercom communication a call is made from

     the door panel, acoustic tones will be heard on the master unit handset and the picture
     will appear in case of a monitor; press the intercom push button of the master unit 
     to establish communication with the door panel, or press the door release push button to
     activate the lock release.
The reproduced acoustic tones are different depending on their provenance, that allows the
     user to distinguish where the call is made from.

Содержание Stadio Plus T500ML

Страница 1: ...71 Stadio Plus Instructions manual Audio and Video door entry system digital installation T500ML rev 0205 ...

Страница 2: ...half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication progresses with one press the door release operates during 3 seconds During the lock release activation an acoustic tone will be heard on the door panel confirming the lock release is activated O The monitor an...

Страница 3: ...f the door panel should be placed at 1 65m height roughly The hole dimensions will depend on the number of door panel modules The door panel has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry systems avoid direct incidence from light sources reparin...

Страница 4: ...N marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the module by screwing the shafts Repeat this procedure in case of door panels with one more module the maximum number of modules placed vertically is three Insert the header UP marked in the last module an...

Страница 5: ...el on the embedding box insert the hinges in the embedding box lockers as shown old the door panel on the embedding box H For a quality finish pass the push buttons wires through the spacer hole of the closest module 2 It s recommended to use wires of less than 0 25mm section IMPORTANT link the push buttons common terminal of the several push buttons modules The common terminal of the push buttons...

Страница 6: ...6 circuits With 5 EL516 circuits With 6 EL516 circuits With 7 EL516 circuits With 8 EL516 circuits 8 7 15 22 6 15 15 36 5 15 15 15 50 4 15 15 15 15 64 3 15 15 15 15 15 78 2 15 15 15 15 15 15 92 1 15 15 15 15 15 15 15 106 0 15 15 15 15 15 15 15 15 120 To other encoders or push buttons 1 P2 1 P1 31 P4 61 P6 91 P8 16 P3 46 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 ...

Страница 7: ... installations the EL562 module must be plugged in all the monitors and JP2 jumper of the EL500 circuit must be placed on the position specified on page 83 Refer to the specific installation diagram escription of the configuration dip switch D Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is finished return the switch to OFF position The programm...

Страница 8: ...case of a FA Plus model IMPORTANT Link power supplies to connect more units than the specified as it s shown IMPORTANT on page 96 IMPORTANT The power supply must be installed in a dry and protected place It s recommended to protect the power supply by using a thermo magnetic circuit breaker and to use a ground connection ock release installation L inal adjustments F lose the door panel C Fix the d...

Страница 9: ... Floor Door Stair PLATEA Plus 0000000000 Nº serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment holes Identification label Connecting points CN4 connector Three positions call reception volume control Cable slot Contrast control color control in case of color screen Brightness control Monitor ...

Страница 10: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L562 module for video installations E with twisted pair cable andling the end of line jumper H hanging the front film C The end of line jumper is placed on the CN4 connector that can be located on the monitor base In case of twisted pair cable installations the end of line jumper is placed in the E...

Страница 11: ...de In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release push button With the door release push button pressed switch on the monitor To show that the system is ready for programming the door panel will reproduce a sound and the picture will appears on the mo...

Страница 12: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description T positive ground audio digital communication intercom auxiliary calling device output door bell push button input A D INT SA HZ A D _ SA INT HZ TELEPHONE INSTALLATION ix the telephone F It will be necessary to open the telep...

Страница 13: ...slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set to OFF the programming switch If you don t the door panel will reproduce a sound to advise that the system is still into programming mode M R B O T R 3 TF 104 SEC CV CV D Malla Vin Ain Aout Vin Vou...

Страница 14: ...istributor INSTALLATION DIAGRAMS ideo installation with coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels w...

Страница 15: ... Terminal SECTIONS CHART 50m Distance 150m A A A D in out V V V M in out p d p d CV CV INSTALLATION DIAGRAMS ideo installation without coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire ...

Страница 16: ... A 1 00mm 2 50mm 0 25mm 0 25mm Terminal SECTIONS CHART 50m Distance 150m A A A D in out CV CV Place this power supply as closest as possible to the first telephone The installation diagram shows the connection of an audio system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one do...

Страница 17: ...ART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17 shield and 20 hot of the SCART connector ntercom function I Platea Plus monitor and T 940 Plus telephone have intercom facility between two units of the same apartment To enable this function check...

Страница 18: ...nits with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c If not disconnect the power supply from the installation and measure again If it s correct now it means there is a short circuit in the installation disconnect the power supply from mains and chec...

Отзывы: