34
Exit button connection
External CCTV camera connection
Doorbell push button connection
The exit button allows the remote activation of the lock release connected between the CV- and CV + terminals (by
default) or the relay output (see page 36). The delay time for activation is 3 seconds, it being possible to adjust it
between 0.5 and 10 seconds (see page 36).
It is possible to connect an analog CCTV camera to each of the door panels, and they can be viewed (see page 35)
from the monitor or the mobile application. The camera must have local power.
Connect the doorbell push button to the HZ inputs of the monitor you want to ring.
CV-
GND
BUS
C
CV+
CCTV
AP+
AP-
BUS
NA
CV-
GND
BUS
C
CV+
CCTV
AP+
AP-
BUS
NA
HZ
HZ
SOUL S5110/ART 7W VIDEO INTERCOM KIT
INSTALLATION DIAGRAMS