WIRING DIAGRAMS:
Two apartments with 4 PENTHA monitors, 2 D2L-GB2 distributors and Golmar DC lock release.
20
BUS
BUS
BUS
BUS
D2
D1
D2L-
GB2
( )
2
BUS
BUS
BUS
BUS
BUS
BUS
BUS
BUS
D2
D1
D2L-
GB2
End
of line
ON
*
OFF
End
of line
Mains
100~240Vac
N
L
CN
BUS (M) BUS(PL)
FA-
2
GB /A
L
Twisted pair 2x0.75mm
2
Twisted pair 2x1mm
2
6 m
0
A
55m
B
30m
C
65m 60m 30m
Cable
10m
D
15m
( )
3
( )
3
Distances with Golmar RAP-2150 cable
(twisted pair 2x1mm ).
2
Set the jumper in this position for 7” GB2 monitors of
all of the D2L-GB2 distributors.
(1)
(1)
(1)
Configure the end of line in the last monitor.
DIP 6 to ON.
**
Remove the jumper from all of the distributors
except the last.
*
Distances and cross-sections:
D
-
2L GB2
A
C
B
C
D
FA-
2
GB /A
Access panel
ON
1 2 3
SW1
AP
( )
2
AP- C1 NA1
AP+
CV-
BUSBUS
CV+
Lock release
max. 12 Vdc/270mA.
( )
2
APARTMENT 2
APARTMENT 1
NOTE: Up to 4 Pentha monitors per installation.
JAZZ GB2 VIDEO DOOR ENTRY SYSTEM KIT - HOUSE
CODE 0
**
CODE 16
**
CODE 17
**
CODE 1
**
PENTHA
PENTHA
PENTHA
PENTHA
PENTHA
PENTHA
Important:
For AC lock release, 2nd AC lock release or automatic gate, see wiring diagrams p. 22.