background image

               

 

 

 

13. SPARE PARTS-Cont’d 

 

MODEL: FRG-1, FRG-1L CONT. 

 

 ITEM No.         CODE       DESCRIPTION 

 
45. 

GCU00003 

BULB & CAPILLARY FOR MINISIT 

46. 

ETC00891 

CONTROL – DIGITAL SIT 891 FRYER FRE-D 

47. 

EPR00100 

PROBE – 4mm FOR SIT 891 FRYER FRE-D 

48. 

MKNPLMS2  KNOB – MINISIT (120 x~200 x C) 

49. 

GET00005 

ELECTRODE – CERAMIC HEAT ROD SENSOR 

50. 

ETC00892 

CONTROL UNIT – CAHO SR-T701 (UNIT K) 

51. 

EPR00102 

FRYER PROBE – FRE WITH 3 WIRES PT THERMOCOUPLE 

52. 

ETC00893 

CONTROL UNIT – FRE PT 100 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
IM011B2/p24 

Содержание FRG-1

Страница 1: ...ROUDLY AUSTRALIAN MADE INSTALLATION PROCEDURE USER MANUAL SERVICE INSTRUCTION MODELS FRG 1 2 3 FRG 24 48 72 GAS APPROVAL NO 2149 SC333 ESTABLISHED 1911 The Cooking Equipment Professionals www goldsteineswood com au ...

Страница 2: ...Page 7 8 9 5 LIGHTING INSTRUCTIONS Page 10 6 DRAINING FILTERING INSTRUCTIONS Page 11 12 7 TECHNICAL DATA Page 13 8 SERVICING Page 14 15 9 TROUBLE SHOOTING Page 16 17 18 10 WIRING DIAGRAM Page 19 11 CONTROLS Page 20 12 DRAWINGS Page 21 22 13 SPARE PARTS Page 23 24 14 WARRANTY Page 25 15 BRANCHES Page 26 IM011B2 p2 ...

Страница 3: ...p Proper installation adjustment and preventative maintenance are vitally important if efficiency and appearance are to be maintained A freestanding 1 2 or 3 deep well automatically controlled gas operated fryer The fryer is mounted on 4 legs with a clearance from floor of 152mm The fryer is equipped with a splash back incorporating a top venting flue outlet Pan outer case and outer surround of st...

Страница 4: ...GULATOR The fryer gas control incorporates a regulator so no regulator is required to be connected into the supply line unless supply gas pressure is greater than 3 45 Kpa Assemble legs to fryer Tilt fryer to rear and screw in 2 legs supplied Tilt fryer to front then screw legs into rear The Fryer should be levelled left to right with a 3mm fall to the front Ventilation Adequate ventilation must b...

Страница 5: ...s fitter or your Gas Company connect the appliance to the mains supply The fitting is 25mm BSP at the line up manifold and 19mm BSP for rear gas entry The appliance must be installed in accordance with the rules of any authority having jurisdiction CAUTION NEVER ALLOW BURNER TO OPERATE WITH FRYPOT EMPTY THIS DAMAGES THE FRYPOT AND VOIDS WARRANTY DO NOT TURN ON MAIN BURNER UNLESS THE OIL IS FILLED ...

Страница 6: ...R FLUING 6 TURN ON GAS OR ELECTRICITY 7 ADJUST GAS PRESSURE WITH THREE QUARTERS OF THE UNIT RUNNING ADJUST GAS PRESSYRE NATURAL GAS 1 00 KPA LPG 2 75 KPA 8 TURN ON ONE AT A TIME TO MAKE SURE ALL IS WORKING E G BURNER RADIANT GRIDDLE AND OVEN 9 SHOW CUSTOMER A HOW TO WORK EQUIPMENT B HOW TO CLEAN C HOW TO PULL IT APART E G TRAYS TRIVETS D ALSO WHAT NOT TO DO E G WATER WITH ELECTRICAL GREASE AND OIL...

Страница 7: ...u give your cooking pots It should be kept clean and bright Oil in deep well fryer is a food and should be handled with care DAILY OPERATION OPENING At opening time always visually check the fryer for a Combination or main gas valve off b To light the fryer see Page 17 or on back of door GENERAL USE OF THE FRYER a For consistent product quality convenience and long term savings use a high quality ...

Страница 8: ...o drain Solid shortening will solidify as it cools and clog the lines CLOSING When closing at night filter the oil in all fryers and drain the filter lines Cover the open tanks of oil Turn the power switch on the fryer panel off and turn the control knob on the combination gas valve to off SHUT DOWN When shutting down for longer than just overnight drain the frying compound clean the vessel thorou...

Страница 9: ...e checked and adjusted periodically by a Qualified service personnel as part of a regular kitchen maintenance program STAINLESS STEEL All stainless steel body parts should be wiped regularly with hot soapy water during the day and with a liquid cleaner designed for this material at the end of each day CAUTION do not let water splash into the tank of hot oil It will splatter and can cause severe bu...

Страница 10: ...down depress and turn gas Valve knob to OFF position JGSD 125 100 0 OVER TEMPERATURE SAFETY CONTROL Prevents fryer from going over 235 C with bulb located front of pan Manual reset control located underneath thermostat knob STRAINING EXCESS CRUMBS Always drain fryer when cooking medium is warm and in liquid state A cool fryer will not drain thoroughly Open drain valve fully and check for any parti...

Страница 11: ...wly to avoid splattering If splattering occurs exercise extreme caution 3 If the drain valve becomes clogged with food particles you may wish to use the Poker like tool This tool must be used from INSIDE the fry pot ONLY Do not hammer on the drain valve as damage to the ball inside will cause it to leak DO NOT insert into front of drain valve in an attempt to unclog the valve hot shortening will r...

Страница 12: ...e knob to the PILOT position and allow the solution to cool 6 Add 3 8 litres of cold water and stir Drain out the solution into a suitable container and clean the fry pot thoroughly 7 Close the drain valve and fill the fry pot with clean water Using a fry pot cleaning brush rinse the fry pot thoroughly Drain and wipe down with a clean dry towel CAUTION ALL DROPLETS OF WATER MUST BE REMOVED FROM TH...

Страница 13: ... 1120 CONVERSION INSTRUCTIONS N G TO L P G 1 Remove injectors from burners and change injector to suitable orifice see gas injectors details table above 2 Remove pilot assembly Change pilot injector NG 2 6 LP 1 6 Stamped on head pilot this Number not a dimension 3 Re assemble pilot assembly 4 Remove the regulator cover screw 5 Insert the spring and pin from the F92 0737 N G to L P G conversion kit...

Страница 14: ...WHEN CLOSING STORE 1 Open fryer door s and rotate gas valve knob s to the PILOT position 2 Depress gas valve knob s and slightly rotate clockwise 3 Release and continue rotating clockwise to OFF 4 Place fry pot covers in place if equipped OPTIONAL EXTRA VENTILATION AND CLEARANCE One of the important considerations of efficient fryer operation is ventilation The fryer must be installed so that prod...

Страница 15: ...PROBLEMS Contact the factory direct by mail or telephone no collect calls accepted Always give the model and serial numbers of your fryer PARTS ORDERING Customers may order parts directly from their local Authorised Parts Distributor For this address and phone number call the factory Factory address and phone numbers are on the back of this manual IMPORTANT GOLDSTEIN CO WHOSE POLICY IS ONE OF CONS...

Страница 16: ...irt Blow out if necessary then re install Check pilot burner orifice for dirt b Pilot burner ignites but will Check that the thermocouple leads not remain lit when gas cock are firmly screwed into pilotstat Manual knob is released power unit bushing on gas control Remove end of thermocouple lead from Pilotstat power unit bushing and clean with fine sandpaper Also check that bushing is clean Thermo...

Страница 17: ...p of the combination gas valve compound does not come up refer to the illustration of the to temperature quickly Manufacturer s bulletin Use a standard water type U gauge manometer With the burner in operation the pressure should be 1 00 kPa and 2 75 kPa on natural and propane gas respectively If not unscrew cover of pressure regulator adjustment Use screw driver to turn adjusting screw clock wise...

Страница 18: ...rratic f Fryer temperature cannot Operating thermostat be controlled runs to high limit temperature g Pilot will not stay on Oil level too low Oil was drained when still hot Solution reset over temp control by removing hexagon nut underneath thermostat knob and press button in finger to reset controller As On Site Fryer Test must be carried out to ensure that problem has been resolved IM011B2 p18 ...

Страница 19: ...10 WIRING DIAGRAM WHITE RODGERS CONTROL IM011B2 p19 ...

Страница 20: ...lame goes out wait five 5 minutes before reigniting 2 Turn knob counter clockwise to pilot position depress knob and light pilot Continue to depress knob until pilot remains alight when knob is released approximately one minute Turn knob to ON position 3 Set thermostat as desired Thermostat will actuate gas flow to the main burner For temporary or permanent shutdown depress and turn gas Valve knob...

Страница 21: ... 2 8 0 195 G A S IN L E T G A S IN L E T 1 9 m m B S P S ID E F R F R G 2 4 F R G 2 4 L 1 9 m m B S P G A S IN L E T V IE W G 2 4 L 8 0 0 1120 195 S ID E V IE W F R G 2 4 6 1 0 F R G 2 4 L F R O N TV IE W 2 4 5 IM011B2 p21 ...

Страница 22: ...12 DRAWING 44 43 45 42 38 37 34 3 39 2 1 6 23 24 30 29 15 14 13 12 11 10 16 40 39 22 26 25 28 27 32 17 2 4 5 1 23 33 18 21 8 24 16 33 31 36 36 7 50 51 52 19 20 49 35 47 46 48 IM011B2 p22 ...

Страница 23: ...B 21 MGLFG00A GLAND FRG PART A 22 FRG18P16 SCRAP ARRESTOR 23 MBKFG180 BASKET FRG18 STANDARD 24 FRG18P27 BASKET HOLDER OLD 24 TGT18P48 BASKET HOLDER NEW 25 FRG18P17 NIGHT COVER 26 MHDCP001 HANDLE 266 76 x 8 C P STEEL FR 27 MHDPL095 HANDLE PLASTIC 3 7 8 98mm BLACK FRG DR 28 MCA00002 CATCH DOOR MAGNET FRYER 29 MLEPLA01 STAINLESS STEEL LEG WITH ADJ PLASTIC INSERT 30 MLEPLBF1 FEET PLASTIC BULLET 2D 31 ...

Страница 24: ...891 CONTROL DIGITAL SIT 891 FRYER FRE D 47 EPR00100 PROBE 4mm FOR SIT 891 FRYER FRE D 48 MKNPLMS2 KNOB MINISIT 120 x 200 x C 49 GET00005 ELECTRODE CERAMIC HEAT ROD SENSOR 50 ETC00892 CONTROL UNIT CAHO SR T701 UNIT K 51 EPR00102 FRYER PROBE FRE WITH 3 WIRES PT THERMOCOUPLE 52 ETC00893 CONTROL UNIT FRE PT 100 IM011B2 p24 ...

Страница 25: ...ip in accordance with the warranty offered This undertaking covers the provision of labour and parts for 12 months from the date of delivery to the purchaser This undertaking applies only to state capitals Remote areas are not covered by this commitment and special enquiries should be made Note Travel time not covered by warranty To the maximum extent permitted by law any liability on Goldstein Es...

Страница 26: ...plex 260 264 Wickham Road Unit 12 Moorabbin 210 Queensport Road Victoria 3189 Murarrie Qld 4172 Phone 03 9553 1488 Phone 07 3890 1811 Fax 03 9553 0785 Fax 07 3890 1788 South Australia Western Australia Suite 26 Unit 1 10 Wittenberg Drive 283 287 Sir Donald Bradman Drive Canning Vale Brooklyn Park Western Australia 6155 South Australia 5032 Phone 08 9456 0559 Phone 08 8238 3423 Fax 08 9456 0554 Fax...

Отзывы: