7. TECHNICAL DATA
C. GAS/INJECTOR DETAILS TABLE
Model
Gas Type
Injector (mm)
T.P.P.
Mj
Pilot No.
FRG
N.G. 2.85 1.00
80
2.6
L.P.G.
1.80
2.65
80
1.6
DIMENSIONS TABLE
FRG
FRG
FRG
FRG
1 2 3 1L
2L
3L
24
48
72
24L
48L
72L
WIDTH
(mm)
457 914 1372
457 914 1372 610 1220
1830 610 1220 1830
DEPTH
(mm)
704 704 704 800 800
800 704 704 704 800 800 800
HEIGHT
(mm)
1120 1120 1120 1120 1120
1120 1120 1120 1120 1120 1120 1120
CONVERSION INSTRUCTIONS N.G. TO L.P.G.
1
Remove injectors from burners and change injector to suitable orifice (see
gas injectors details table above).
2.
Remove pilot assembly. Change pilot injector
NG= 2.6 LP = 1.6
Stamped on head pilot this Number not a dimension.
3.
Re-assemble pilot assembly.
4.
Remove the regulator cover screw.
5.
Insert the spring and pin from the F92-0737 N.G. to L.P.G. conversion kit.
6.
Install regulator cover screw onto regulator.
7.
Affix caution label to top of cover screw.
8.
Check all connections for leaks.
9.
Adjust the T.P.P. to suit L.P.G.
10.
Change Rating Plate.