The Aqua Plus is designed to handle the purification needs of most residential swimming pools up to 40,000 gallons
(150,000 liters), or the needs of most commercial pools up to 25,000 gallons (95,000 liters). Check local codes
for other restrictions. The actual amount of chlorination required to properly sanitize a pool varies due to bather
load, rainfall, temperature, and the pool’s cleanliness.
For pools larger than 40,000 gallons, the Aqua Plus can control one or more Goldline Aqua Rite chlorinators to
supplement chlorine production.
NOTE: Before installing this product as part of a saline water purification system in a pool or spa using natural
stone for coping or for immediately adjacent patios/decking, a qualified stone installation specialist should be
consulted regarding the appropriate type, installation, sealant (if any) and maintenance of stone used around a
saline pool with electronic chlorine generator in your particular location and circumstances.
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged especially in arid regions where
pool water is subject to excessive evaporation and is not commonly diluted with fresh water. Dry acid can cause a
buildup of by-products that can damage your chlorinator cell.
Default Display
Turn power on at the main panel and turn the Aqua Plus control power circuit breaker on. The keypad will show
the default display. The default display alternates between the day/time, air and pool (or spa) temperature, pool/
spa sanitizer setting, and salt level. Under certain circumstances, additional displays may be added to the default
menu to inform you about system operation. Refer to the Programming Menu Flowchart on page 6 to view all
possible displays. The Aqua Plus will automatically scroll through all of the available default menu displays or you
can press “<” or “>” to manually scroll.
33
Air Sensor
94ºF
Cell Temp Sensor
77ºF
Solar Sensor
Short circuit
Water Sensor
Open circuit
No function
No function
No function
No function
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
If the sensor appears to operating properly, then the temperature will be displayed. If this temperature
is not correct then check the placement of the sensor. If the problem is not placement related, then the
sensor will, most likely, require replacement. If the display is “Open Circuit” or “Short Circuit” then
check the wiring to the sensor and also make sure that the wires are secure in the terminal block in the
Aqua Plus main unit.
Main Software
Revision 2.40
Display Software
remote-08 r3.10
RF Base Software
r1.20 ID:1234
Filter Bridge
Software r1.00
6B Spa Software
Remote A r1.00
Filter VSC
Software r1.00
No function
No function
No function
No function
No function
No function
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Chemistry Sense
Software r1.00
No function
Move to previous/next menu item
Available displays depend on configuration.
If you call the Goldline Technical Service Dept. for
assistance, they may ask for the software revisions of both the main unit and each of the display/
keypads or other devices that are attached to the system. Note that it is possible that different
display/keypads have different software revision levels. For this reason, it is advisable to check this
diagnostic menu item on every display.
Pool/Spa
Filter
Lights
Aux 1
Aux 2
Menu
>
>
Service
+
Saturday
11:45A
Heater
Option Valve
Check System