background image

10

Teach Wireless

+ to start

Teach

Successful

 Wireless

Teach

NOT Successful

 Wireless

Teach Wireless

Base NOT Found

Press and hold

wireless button

Push to start process

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Move to previous/next menu item

Press any button on wireless remote

This menu will only appear if a wireless base station is connected to the Aqua Plus.  Perform this

procedure each time a wireless remote control is added to the Aqua Plus system.  During this proce-

dure the wireless remote “learns” and remembers the ID code for the wireless base station connected

to this particular Aqua Plus unit and will reject messages with any other ID codes.  If “Base NOT

found” is displayed, then the Aqua Plus can not communicate with the transmitter/receiver base

station attached to the main unit.  If “NOT Successful” is displayed, then the  base station did not

receive a signal from the remote control.  This may be due to the distance between the Base Receiver

and the remote device being too great or may be due to interference caused by other RF equipment

operating in the neighborhood.  Try changing the channel and then repeat the “Teach Wireless”

command.

Wireless

Channel:  1

Reteach all

wireless units

Confirm Change:

+ to proceed

Push to confirm the channel change

Change the desired wireless channel (1 - 5)

Move to previous (Teach Wireless) menu

If channel is changed, move to confirmation menu

Move to previous/next menu item

If channel is not changed, move to previous/next menu item

This setting changes the channel to be used by the wireless base station and remote(s).  If the channel

is changed and confirmed, all of the wireless remotes will have to be retaught. This menu will only
appear if a wireless base station is connected to the Aqua Plus.

Timers Menu

The Timers Menu allows you to set all timeclock and countdown timers which control the automatic operation of

your pool/spa system.

Each timeclock has a single on/off program per day.  All of the timeclocks are setup (Configuration Menu) either as

“all days” or “weekends/weekdays”.  If “weekends/weekdays” are selected, you will need to program on times for

both weekdays and weekends and off times for both weekdays and weekends, even if you want them to be the

same.  All times are adjusted in 15 minute increments (9:00A, 9:15A, 9:30A, etc.).  If you program the on time

equal to the off time (“10:00A to 10:00A”) the output will NEVER turn on.  If you want to disable a timeclock, you

can set the on time equal to the off time and you will notice the times disappear and the display simply shows “Off”.

If, at a later time, you wish to re-activate the timeclock, simply press either the “+” or “-” buttons to go back to a

normal timeclock programming display.

The Countdown timer is programmed in increments of 5 minutes from “Manual On/Off” (0 minutes) to a maximum

of “21:00” (21 hours).  When “Manual On/Off” is displayed, the countdown timer is disabled and the output will be

manually controlled.  When a countdown timer is equal or greater than “0:05”, pressing the appropriate output

button will turn the output on and start the timer.  Pressing the button again will turn the output off or, when the

programmed time has elapsed, the output will automatically turn off.

25

Chlorinator Operation / Water Chemistry

General Water Chemistry

Salt is required when using the chlorinator feature on the Aqua Plus Control. Refer to the description of the Aqua

Plus configuration menu for information on enabling/disabling the chlorinator (see page 13).

Water Chemistry

The table below summarizes the levels that are recommended by the Association of Pool and Spa Professionals

(APSP).  The only special requirements for the Aqua Plus are the salt level and stabilizer.

Saturation index

The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water

“balance”.  Your water is properly balanced if the Si is 0 ±0.2.  If the Si is below -0.2, the water is corrosive and

plaster pool walls will be dissolved into the water.  If the Si is above +0.2, scaling and staining will occur.  Use the

chart below to determine the saturation index.

The pool’s chemistry must be balanced BEFORE activating the Aqua Plus’s chlorinator function.  NOTE:  If the

pool does not have new water, add metal remover and non-copper based algaecide to the pool, per manufacturer’s

instructions.  This ensures a quick, troublefree transfer to the Aqua Plus system.

ºC       ºF       

 

Ti

Calcuim

Hardness

Ci

Total

Alkalinity

Ai

53

60

66

76

84

94

103

12

16

19

24

29

34

39

.3

.4

.5

.6

.7

.8

.9

How to use: 

Measure pool pH, temperature, calcium hardness,

and total alkalinity.  Use the chart above to determine Ti, Ci,and

Ai from your measurements.  Insert values of pH, Ti, Ci and Ai
into the above equation.  If Si equals .2 or more, scaling and 

staining may occur.  If Si equals -.2 or less corrosion or irritation

may occur. 

Si = pH + Ti + Ci + Ai - 12.1

-.2

0

.2

CORROSIVE

SCALING

75

75

100

100

125

125

150

150

200

200

250

250

300

300

400

400

600

600

800

800

1.5

1.9

1.6

2.0

1.7

2.1

1.8

2.2

1.9

2.3

2.0

2.4

2.1

2.5

2.2

2.6

2.4

2.8

2.5

2.9

OK

Содержание PL-PLUS

Страница 1: ...www goldlinecontrols com 888 921 7665 Automation and Chlorination Operation Manual for models PL PLUS PL PLUS 20 LD C G LINE ON TROLS ...

Страница 2: ...nal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment One bonding lug for US models two for Canadian models is provided on the external surface To reduce the risk of electric shock connect the local common bonding grid in the area of the swimming pool spa or hot t...

Страница 3: ...perate the Spa Manually 23 Guide Operate the Spa Automatically 23 Set the Heater Temperature 23 Set the Chlorinator Output 23 Start Stop Superchlorination 24 Program a Timeclock 24 Program a CountdownTimer 24 Enter Exit Service Mode 24 Chlorinator Operation Saturation Index 25 Water Chemistry Salt Level 26 Type of Salt 26 How toAdd or Remove Salt 26 System Maintenance Servicing and Cleaning the Tu...

Страница 4: ...tch theAqua Plus is also an automatic chlorine generation system for pool and or spa sanitization When enabled see Configuration Menu this operation requires a low concentration of salt sodium chloride in the pool spa water TheAqua Plus automatically converts the salt into freechlorinewhichkillsbacteriaandalgaeinthepool spa Chlorinewillrevertbacktosodiumchlorideafterkilling bacteria Thesereactions...

Страница 5: ...sed around a salinepoolwithelectronicchlorinegeneratorinyourparticularlocationandcircumstances NOTE The use of dry acid sodium bisulfate to adjust pool pH is discouraged especially in arid regions where poolwaterissubjecttoexcessiveevaporationandisnotcommonlydilutedwithfreshwater Dryacidcancausea buildupofby productsthatcandamageyourchlorinatorcell Default Display Turn power on at the main panel a...

Страница 6: ...n off after 5 minutes of heater cooldown operation If you want to override the heater cooldown simply press the FILTER button again to turn off the filter pump Two Speed or Variable Speed Filter Pump If the pump is currently off simply press the FILTER button to turn onhighspeedoperationofthefilterpump The Filter LEDwillilluminatecontinuously Pressingthe FILTER buttonagainwillswitchtolowspeedopera...

Страница 7: ...operation right LED illumi nated PressingthePOOL SPAbuttonagainwillswitchbacktopool only Notethatthefilterpumpwillturnoff whilethepool spavalvesareturning Pool and Spa systems with spa spillover In pool only mode the left LED next to the POOL SPAbutton is illuminated Pressing the POOL SPAbutton will switch theAqua Plus to spa only operation right LED illumi nated Pressing the POOL SPAbutton again ...

Страница 8: ...llthroughthevariousitemsintheselectedmenu Multiplepushes ofthebuttonwillrotatethroughallmenuitemsandreturntothestartingpoint Onlymenu itemsthatareapplicabletoyourpoolwillappear Example ifyoudon thaveaspa then no spa related menu items will appear 3 Onceamenuitemhasbeenselectedabove thecurrentsetting selectionwillappear flashing on the display Use the and or keys to change this selection Sometimes ...

Страница 9: ...rinator setting spa high low speed pool high low speed day and time backlit display light beeper teach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter pump1 or hi speed pool filter pump2 or lo speed spa lights aux1 aux2 valve3 superchlorinate diagnostic menu chlorinator diagnostics instant salt pH ORP levels flow switch cell temper...

Страница 10: ... you have both solar heat and a conventional heater and the solar priority option is selected Configuration Menu then the conventional heater will only operate when solar heat is NOT available Pool Heater1 Off Adjust the desired pool temperature Off 65 F 66 F 103 F 104 F Off Move to previous next menu item The pool heater setting will only appear if the system has been setup for pool only or pool ...

Страница 11: ...e The actual amount of chlorine introduced into the spa is determined by this setting the amount of time the pool operates in spa only mode the water temperature and the amount of salt in the water If the filter pump is running due to the freeze protection feature then the chlorinator will not operate during this time Pool Chlorinator 60 Adjust the desired chlorinator output for pool 0 1 2 3 9 10 ...

Страница 12: ...the Aqua Plus and are also displayed as part of the default menu The Aqua Plus is designed to keep the clock running during power outages lasting less than 7 days If power has been off for longer than 7 days then the time may have to be reset Display Light On for 60 sec Toggle between Always On and On for 60 sec Move to previous next menu item This function controls the backlight on the display If...

Страница 13: ...o previous next menu item If channel is not changed move to previous next menu item This setting changes the channel to be used by the wireless base station and remote s If the channel is changed and confirmed all of the wireless remotes will have to be retaught This menu will only appear if a wireless base station is connected to the Aqua Plus Timers Menu TheTimers Menu allows you to set all time...

Страница 14: ... operation during this programmed time period These include manual operation spa operation or heating operation Refer to page 10 for general notes regarding timeclock programming This menu is only available if the system has been setup for pool and spa During the programmed spa time the Aqua Plus will turn on the filter pump and move the pool spa valves into the spa only position The heater will a...

Страница 15: ...e programmed off time it may be because of freeze protection Also manual operation overrides the timeclock This menu will appear only if theAux1 is configured for countdown timer This setting is the time after you manually turn on theAux relay until theAqua Plus automatically turns off the relay You can also manually turn off the relay at an earlier time by pressing theAUX1 button Set Day and Time...

Страница 16: ... desired output setting see Settings Menu in the Operation manual If disabled all displays relating to the chlorinator will be suppressed When the chlorinator is enabled theAqua Plus will automatically detect and control anyAqua Rite s that is installed in the system Display Allows for the display of salt default or mineral values Cell Type Selection The Cell Type Menu appears after Display Salt M...

Страница 17: ...ns the valves to their previous positions It is programmed in increments of 5 minutes from Manual On Off 0 minutes to 21 00 21 hours The filter is forced on during this time period Spa Spillover When spa spillover is Enabled and Pool and Spa the homeowner will be able to rotate through Pool Only both suction and return valves switched to pool Spa Only both suction and return valves switched to spa...

Страница 18: ...ntrolled by commands sent to the pump Lowest Speed This is the lowest speed that the variable speed pump is allowed to run at It is used as the lower limit in the Low Speed Settings Menu Set lowest speed from 10 default to 50 Highest Speed This is the highest speed that the variable speed pump is allowed to run at It is used as the upper limit in the High Speed Settings Menu Also this is the speed...

Страница 19: ...ture setting will be used Heater1 Cooldown This feature ensures that the heater cools down before water circulation is stopped When enabled theAqua Plus will continue to run the filter pump for 5 minutes after the heater turns off During this period the filter pump LED will flash and also a Heater Cooldown X XX remaining message will scroll on the display When the filter pump is running and the he...

Страница 20: ...erature is in the Settings Menu If applicable the homeowner will be prompted to enter separate pool and spa desired temperature settings Depending on the position of the pool spa suction valve the proper temperature setting will be used Solar Extend If Enabled the filter extend logic keeps the filter pump running beyond the normal turn off time if solar heat is still available When solar heat is n...

Страница 21: ... Timers Menu in Operation Manual The LIGHTS button can also be used to turn the output off Low Speed of a 2 speed Filter Pump the Aqua Plus will turn on the lights relay whenever the low speed operation of the filter pump is required It is very important that the 2 speed filter pump option be selected under the Filter Config Menu for proper operation Timeclock the lights relay will turn on and tur...

Страница 22: ...bled and Disabled default Move to previous next configuration menu WARNING Do not use the Aqua Plus to control an automatic pool cover Swimmers may become entrapped underneath the cover Aux1 Function Manual On Off default the aux relay will alternate between turning on and off when the aux button is pressed There is no automatic control logic Countdown Timer the aux relay will turn on when the AUX...

Страница 23: ...olar and super chlorinate for all functions except solar or super chlorinate Valve3 Ext Input Disabled Toggle between Enabled and Disabled default Move to previous next configuration menu Valve3 Function Timeclock default the valve turns on off at the times set for the valve3 timeclock in the Timers Menu see Operations Manual The VALVE3 button can also be used to turn the valve output on or off So...

Страница 24: ...he AQL SS 6B to one of the standard Aqua Plus functions The default selections are Button 1 Pool Spa Button 2 Filter Button 3 Lights Button 4 Heater1 Button 5 Aux1 and Button 6 Aux2 Remote Menus Enabled Toggle between Enabled default and Disabled Remote Menus Move to previous next configuration menu This feature will prevent unauthorized access to the Settings Timers and Configuration menus from a...

Страница 25: ...n is NOT reversible be careful Maintenance Menu only displays if Sensing System is enabled The Maintenance Menu will be displayed only if the optionalAQL CHEM is used and the Sensing System is enabledintheChemistryConfig Wizard ThismenuisusedtoperformfunctionsrelatingtotheAQL CHEMORP andpHsensingkit pH Calibration Wizard to enter Push to access pH Calibration Wizard Move to previous next menu item...

Страница 26: ...ation is the highest priority and will take precedence over other automatically programmed operations At the end of the spa period the Aqua Plus will return to its normally programmed operation state Set the Heater Temperature or turn heater permanently off 1 Pressthe MENU buttonrepeatedlyuntil SettingsMenu isdisplayed 2 Press the button repeatedly until the Spa Heater1 or Pool Heater1 is displaye...

Страница 27: ...kday settings Note During the programmed time there may be other automatic or manual operations that prevent the relay valve from operating see a more detailed discussion under Automatic System Operation Timers Menu Aux Timeclock or in Troubleshooting Diagnostic Information Program a Countdown Timer 1 Pressthe MENU buttonrepeatedlyuntil TimersMenu isdisplayed 2 Press the button repeatedly until th...

Страница 28: ...lingandstainingwilloccur Usethe chartbelowtodeterminethesaturationindex The pool s chemistry must be balanced BEFORE activating theAqua Plus s chlorinator function NOTE If the pooldoesnothavenewwater addmetalremoverandnon copperbasedalgaecidetothepool permanufacturer s instructions This ensures a quick troublefree transfer to theAqua Plus system ºC ºF Ti Calcuim Hardness Ci Total Alkalinity Ai 53 ...

Страница 29: ...son should be minimal This loss is due primarilytotheadditionofwaterbecauseofsplashing backwashing ordraining becauseofrain Saltisnotlost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl salt that is greater than 99 0 pure This can be found at most poolstoresin40 80lb bagslabeled foruseinswimmingpools Alternatively usecommonfoodqualityorwater softenersaltthat...

Страница 30: ...63 1600 160 73 187 85 213 97 240 109 267 121 293 427 133 195 320 453 145 207 347 480 158 219 373 507 170 231 400 533 182 243 1800 140 64 163 74 187 85 210 95 233 106 257 373 117 169 280 397 127 180 303 420 138 190 327 443 148 201 350 467 159 211 2000 120 100 80 60 20 40 55 45 36 27 9 18 140 117 23 47 64 53 11 21 160 133 27 53 73 61 12 24 180 150 30 60 82 68 14 27 200 167 33 67 91 76 15 30 220 320 ...

Страница 31: ...0 9 5 16 4 7 4 22 2 10 0 17 2 8 0 23 3 10 5 6 0 2 7 4 0 2 7 6 0 2 7 6 0 2 7 8 5 3 9 7 0 3 2 9 0 2 2 10 0 4 5 10 0 4 5 14 2 6 3 11 0 5 0 16 0 7 2 13 0 5 9 18 0 8 1 14 0 6 4 19 0 8 6 15 0 6 8 20 0 9 0 5 0 2 3 3 3 2 3 5 0 2 3 5 9 2 7 4 2 2 7 6 7 3 0 8 4 3 8 6 7 3 0 7 5 3 4 9 2 4 2 13 3 6 0 10 8 4 9 15 0 6 7 11 7 5 2 15 8 7 1 12 5 5 6 16 7 7 5 4 0 1 8 2 7 1 8 4 0 1 8 4 0 1 8 5 7 2 6 4 7 2 1 3 3 2 1 5 ...

Страница 32: ...o wear rubber gloves and appropriate eye protection Thelevelofthesolutioninthecontainershouldjustreachthetopofthecellsothatthewireharnesscompartment isNOTsubmerged Itmaybehelpfultocoilthewiringbeforeimmersingthecell Thecellshouldsoakforafew minutesandthenrinsewithahighpressuregardenhose Ifanydepositsarestillvisible repeatsoakingandrinsing Replacecellandinspectagainperiodically Winterizing TheAqua ...

Страница 33: ...ically return to normal operation after 3 hours During service timed operation the SERVICE LED will flash and the time remaining will be displayed on the remotedisplay keypad s Pressingthe SERVICE buttonagain willreturntheAquaPlustonormal automatic operation Check System Indicator The CHECKSYSTEM LEDwillalertyouwhentheAquaPlusdetectsanyofthefollowingconditionsthatare abnormal and require attention...

Страница 34: ...he selected timeout without reachingthedesiredlevel Checkthechemicalsupplyandthe feeder IfbothareOK thetimeoutmayneed to be increased Press the button to reset the alarm and resume dispensing pHCalibrationError WhenusingthepHCalibrationWizardandtheenteredtestresultwasdifferentfrom the measured pH level by 1 0 or more The pH probe may need to be cleaned or replaced ORP Probe Error If the CSM indica...

Страница 35: ...or will turn off wait for 15 seconds and then turn on in the opposite polarity If a conventional or solar heater is operating it is likely that the temperature of the water at the cell is higher than the pool spa water temperature displayed on the Aqua Plus default display Instant Salt 3200 PPM save Move to previous next menu item Press to load the Instant Salt into the averaged salt display This ...

Страница 36: ...2 40 Display Software remote 08 r3 10 RF Base Software r1 20 ID 1234 Filter Bridge Software r1 00 6B Spa Software Remote A r1 00 Filter VSC Software r1 00 No function No function No function No function No function No function Move to previous next menu item Move to previous next menu item Move to previous next menu item Move to previous next menu item Move to previous next menu item Move to previ...

Страница 37: ...34 ...

Страница 38: ...35 ...

Страница 39: ...process of installation 2 Damageresultingfromimproperinstallationincludinginstallationonpoolslargerthantheproductrating 3 Problems resulting from failure to install operate or maintain the product s in accordance with the recom mendationscontainedintheownersmanual s 4 Problemsresultingfromfailuretomaintainpoolwaterchemistryinaccordancewiththerecommendationsin theownersmanual s 5 Problems resulting...

Страница 40: ...decrease pump filtration time Too low add soda ash Too high add muriatic acid Alkalinity 80 120 ppm Salt 2700 3400 ppm Add salt as required to increase Add baking soda to increase Stabilizer 60 80 ppm Add cyanuric acid to increase Calcium 200 400 ppm Add calcium to increase Electrolytic Cell inspect clean Refer to section in manual TEST IDEAL RANGE ADJUSTMENT REQUIRED Drain and add water to decrea...

Отзывы: