The healthy alternative in water purification 

 

RC-50 USER MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

with built-in 

 
 
 

 

6/12 

CLM-284 

Summary of Contents for MineralPURE RC-50

Page 1: ...8 800 700 65 50 www bassein servis ru The healthy alternative in water purification RC 50 USER MANUAL with built in 6 12 CLM 284...

Page 2: ...J Troubleshooting 20 22 K Optional RC 50 Components 22 L RC 50 Specifications 23 Thank you for purchasing the RC 50 MineralPURE ScaleBlaster unit for your swimming pool Using new state of the art mic...

Page 3: ...mponents listed below Copper Test Kit 1 CLA 41 ScaleBlaster Signal Wire 60ft 12 Zip Ties 3 Control Unit 1 Users Manual 1 Control Unit Mount ing Brackets 4 Mounting Bracket Screws 4 Electrode 1 CLE 11...

Page 4: ...A Identifying the RC 50 Components 8 800 700 65 50 www bassein servis ru CET 0607 Warranty Card 1...

Page 5: ...ount the RC 50 control box on a wall and within 10 feet or so of where you will install the electrode chamber and ScaleBlaster signal coil on the return line of your pool equipment This location will...

Page 6: ...t is not required if there is not enough space If necessary you can re pipe an entire section to allow proper room for the electrode chamber or ScaleBlaster coil 4 Using a hacksaw or pipe cutter cut o...

Page 7: ...heet on during installation to stay clear of scratching the unit 1 Install the four mounting brackets using the enclosed screws to the back of the control box 2 Mount the microprocessor control box to...

Page 8: ...D side on the timer box It makes no difference which colored wire goes to the two load screws Connect the green wire to GROUND When installed properly the unit should come on and off when the pool pum...

Page 9: ...or You should use a flexible conduit from connection to connection on the power cord to meet codes The size of the connector already on the control box is 1 2 There is no need to cover up the electrod...

Page 10: ...s possible with the signal cable completely threaded through he hole 2 Route the signal cable from the power unit s terminal to the location where signal cable will be wrapped Hold the cable parallel...

Page 11: ...TDS level is very high and should be lowered If the pool was using chlorine it is all right to go ahead and install the MineralPURE as the two work together fine In fact some chlorine should be in th...

Page 12: ...otal alkalinity is over 120ppm Lower the total alkalinity by adding muriatic acid Consult chart with your test kit for the amount to add The calcium hardness level should be between 150 350ppm If the...

Page 13: ...0556 0 1250 0 70 0 778 0 1750 1 00 0 1111 0 2500 When all of the above steps have been completed it is time to start up the system Open all valves and turn the power on Check for water leaks and all...

Page 14: ...sure you wait 3 minutes for the test to develop and look down into the tube not from the side There is a reading or color match for 0 2 and one for 0 3 on the enclosed chart Ideally we would like the...

Page 15: ...ee water in a few minutes Tablet in skimmer Add a 3 Trichlor tablet in the skimmer for continuous oxidizing The reading will be so low that it won t be detectable This is ideal for pools with heavy sw...

Page 16: ...d lemon juice or a muriatic acid water solution scrub the buildup off the electrode If the electrodes are thin and worn out they will need to be replaced You should replace the reagents at least once...

Page 17: ...ay Clear Lid Latch Output Adjust Knob Power Cable Scaleblaster Coil Binding Post Electrode Cable The RC 50 control box has one LCD display screen and one control knob for easy to use simplicity Output...

Page 18: ...lacing See the section on Inspecting and Replacing the Electrodes for more information BLINKING with SHORT SHORT CIRCUIT on ELECTRODE This error mode is very unlikely to occur If it should happen most...

Page 19: ...wires 5 INSPECT ELECTRODE MAKE SURE TDS IS NOT TOO LOW This message will be displayed if the user is setting the output current to a level that the control unit is unable to obtain This is caused by t...

Page 20: ...qual the current set value DUTY CYCLE OF OUTPUT When in the pulse width modulation mode this is the ON time of the current output to the electrodes TOTAL HOURS UNIT HAS BEEN ON Total time in hours the...

Page 21: ...first or pouring it directly into the skimmer If you are unable to obtain the proper ion level check all of the following factors to solve the problem 1 High algae growth and cloudy water Ion level t...

Page 22: ...electrodes on steel piping Cut out a section of this and replace with PVC pipe 10 Improper installation Sometimes installers will mount the electrodes on a bypass line and not on the actual return li...

Page 23: ...ter Enviro Technologies Inc with RMA number clearly written on the outside of the box and description of problem on a note inside with the circuit board Without RMAnumber your package may be delayed i...

Page 24: ...ODE one set 3 comprised of copper CLE 11 or copper silver CLE 42 or CLE 44 ELECTRODE CHAMBER specially designed 2 black tee with bushings ENCLOSURE weather resistant NEMA 12 rated high impact corrosio...

Page 25: ...8 800 700 65 50 www bassein servis ru The Healthy Alternative to Chlorine Manufactured by Phone 727 562 5186 Toll Free 800 756 7946 Fax 727 562 5187 clearwater enviro com MineralPURE com...