11
For one speed pumps, this is the first filter timeclock and will determine the normal hours of
filtration for the pool. For pool/spa combination systems with spillover enabled, the valves
will automatically switch to spillover mode at the start of the filtration period. For all other
systems, the valves will switch to the pool-only position. Refer to the text above for general
notes regarding timeclock programming.
For two speed or variable speed pumps, this setting will be the period of time when the pump
runs at high speed (the word “Filter T1” in the display will be replaced with “Filter Hi”).
There is a separate timeclock for the low speed operation (see “Filter T2” below). If the high
speed and low speed periods overlap, then the pump will operate in low speed during the
overlap period.
There are several reasons the filter pump may be running at times other than the timeclock
period set above. These include super-chlorination, spa operation, manual operation, heater
cooldown, freeze protection and “solar-extend”.
For one speed pumps, this is the second filter timeclock
For two speed or variable speed pumps, this timeclock will set the normal time period for
filter pump low speed operation
(the word “Filter T2” in the display will be replaced with
“Filter Lo”). If the filter pump was off prior to the start of this time period, the filter pump will
first turn on at high speed for 3 minutes to prime and establish water flow. Afterwards, it will
drop down to low speed for the remainder of the programmed low speed time period. While
this time clock will override the high speed timeclock (see above), there are several reasons
why the pump will automatically switch to high speed operation during this programmed
time period. These include manual operation, spa operation, or heating operation. Refer to
page 10 for general notes regarding timeclock programming.
This menu is only available if the system has been setup for “pool and spa”. During the
programmed spa time, the Aqua Plus will turn on the filter pump and move the pool/spa
valves into the “spa-only” position. The heater will automatically heat the spa up to the
programmed spa temperature (page 7). This programmed spa operation will take precedence
over all other automatic functions, only manual operation of the filter button or pool/spa
valve button will override this function.
If your pool has a separate jet pump or blower controlled by Aux1 and/or Aux2 , you will have
to program those separately.
24
Note: Separate chlorinator output levels for the pool and spa must be set. If the valves are in
the pool-only or spa spillover positions, then the chlorinator will operate according to the pool
setting. If the valves are in the spa-only position then the chlorinator will operate according to
the spa setting. The actual amount of chlorine introduced into the pool/spa is determined by:
this output setting, the amount of time the filter pump is running, the water temperature, and
the amount of salt in the water. Also see Start/Stop Superchlorination.
Start/Stop Superchlorination
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed
2. Press the “>” button repeatedly until “Super Chlorinate” is displayed.
3. The display will show whether superchlorination is “on” or “off”.
4. Press “+” or “-“ to toggle between “on” and “off”
Note: Once started, superchlorination will run for the programmed number of hours (Timers
Menu/Super Chlorinate Hours) or until you manually turn it off. Superchlorination may be
temporarily interrupted for a programmed spa operation.
Program a Timeclock
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until “xxx—all” or “xxx—wkend” (where xxx is the parameter that you
want to program) is displayed.
3. Use the “+” and “-“ buttons to set the desired start time, then press “>” to switch to the off time. Use
the “+” and “-“ buttons to adjust the off time. If you are setting the “weekend” timeclock, press “>” to
go to the “weekday” settings.
Note: During the programmed time, there may be other automatic or manual operations that
prevent the relay/valve from operating—see a more detailed discussion under Automatic System
Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diagnostic Information.
Program a Countdown Timer
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until the “xxx—Timer” (where xxx is the parameter that you want to
program) is displayed.
3. Use the “+” and “-“ buttons to set the desired timer period.
Note: A setting of 0:00 will display as “manual on/off”. The countdown automatic turn off
function is disabled but manual operation is still permitted. There may be other automatic or
manual operations that prevent the relay/valve from operating—see a more detailed discussion
under Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diag-
nostic Information.
Enter/Exit Service (or Service—Timed) Mode
1. Go to Aqua Plus main unit (normally mounted near the pool equipment)
2. Pressing the “Service” button rotates through normal operation (red LED off), service mode (red LED
on continuously) and service-timed mode (red LED flashing).
Note: This operation can only be performed at the main Aqua Plus unit. Both “Service” and
“Service-Timed” disable all automatic programmed operations and allow manual operation
from the main unit only. The buttons on the remote display/keypads will still be able to turn
equipment off in case of an emergency, but will not turn any equipment on. If the system is in
“Serviced-Timed” it will automatically switch back to normal operation at the end of the 3 hour
time period.
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Filter T1-all
8:30A to 4:00P
Filter T1-wkend
8:30A to 4:00P
Filter T1-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Filter T2
8:30A to 4:00P
-all
Filter T2-wkend
8:30A to 4:00P
Filter T2-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Spa-all
6:00P to 9:00P
Spa-wkend
6:00P to 9:00P
Spa-wkday
6:00P to 9:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item