background image

Thank you for purchasing this Goldair Platinum product. Your product is warranted against faults and manufacture when used in
normal domestic use for a period of

three years.

In non-domestic use Goldair limits the voluntary warranty to

three months.

Goldair undertake to repair or replace this product at no charge if found to be defective due to a manufacturing fault during the
warranty period.

This warranty excludes damage caused by misuse, neglect, shipping accident, incorrect installation, or work carried out by anyone
other than a qualified electrical service technician.

PLEASE KEEP YOUR RECEIPT AS THIS WILL HELP VERIFY YOUR WARRANTY.

The benefits given to you by this warranty are in addition to other rights and remedies available to you under law in relation to the
goods or services to which this warranty relates.

In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a
replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a
major failure.

In New Zealand this warranty is additional to the conditions and guarantees of the Consumers Guarantee Act (1993).

Three Year Warranty

Goldair Three Year Warranty 

(IMPORTANT: Please complete and retain this warranty card)

Name

Address

Place Of Purchase

Date Of Purchase

Name Of Product 

Model Number

Attach a copy of the purchase receipt  to this warranty card

Due to continual design improvements, the product illustrated in this User Manual may differ slightly from the actual product.

Goldair

New Zealand

CDB Goldair
PO Box 100-707
N.S.M.C
Auckland

Phone +64 (0)9 917 4000
Phone 0800 232 633

www.goldair.co.nz

Goldair

Australia

CDB Goldair Australia Pty

PO Box 574

South Morang

Victoria, 3752

Phone +61 (0)3 9365 5100

Phone 1300 GOLDAIR  (1300 465 324)

www.goldair.com.au

Содержание PLATINUM GPDH390

Страница 1: ......

Страница 2: ...This page is intentionally left blank ...

Страница 3: ... To reduce the risk of fire keep textiles curtains or any flammable material a minimum distance of 1 metre from the air outlet General Care and Safety Guide Use only the voltage specified on the rating label of the appliance The dehumidifier must not be located immediately below a socket outlet Keep all objects at least 1 metre from the front sides and rear of the appliance This appliance is inten...

Страница 4: ... off Do not remove plug from power socket by pulling cord always grip plug Do not place cord under carpet or cover with rugs or furniture Arrange the cord so it cannot be tripped over Don t place appliance on bedding or on thick long carpet where the openings may get blocked Switch off and use handle provided when moving Do not place appliance close to radiant heat source Do not insert or allow fo...

Страница 5: ... separate timer remote control system or any other device that switches the dehumidifier on automatically since a fire risk exists if the dehumidifier is covered or positioned incorrectly WARNING Never leave this dehumidifier unattended Ensure dehumidifier is on a flat stable heat resistant surface Once the dehumidifier is in a safe operating position and all switches are in the off position inser...

Страница 6: ...dicated on the LCD display When ambient humidity is 5 lower than your setting compressor shuts off and fan works at low speed If ambient humidity is 5 higher than the setting the dehumidification is activated again When the machine is set in continuous dehumidification the continuous dehumidification mode and corresponding fan speed will be displayed on LCD In this mode the ambient humidity has no...

Страница 7: ...ss this key to start swing and the louvre oscillates automatically and the swing pattern is displayed on LCD Press this key again and the louvre will stop at that position DEFROST When the dehumidifier works in low temperature frost will be produced on the surface of evaporator To ensure the dehumidifier performs well the automatic defrost function is designed with the dehumidifier 1When the tempe...

Страница 8: ...the drain spout 2 Place the end of the drainage hose in a drainage outlet Ensure that the end of the hose is lower than the drain opening otherwise the water will not drain and flooding may occur 3 Also ensure the water tank is positioned in the unit otherwise the continuous drainage will not operate It will also catch any overflow 4 When you no longer wish to use the permanent water drainage disc...

Страница 9: ... is dry before plugging back into the mains supply TO CLEAN THE AIR FILTER Unplug the appliance from the mains supply Remove the filter Clean the filter with a vacuum or with water Dry the filter Ensure the filter is completely dry before placing back in the unit Never use unit without the air filter Do not attempt to dismantle the appliance There are no user serviceable parts For service or repai...

Страница 10: ...nstructions in user manual The temperature or relative humidity in the room is too low It is normal for the Dehumidifier not to operate in low humidity or low temperatures The Dehumidifier operates but reduces the relative humidity in the room by small amounts The room which the Dehumidifier is operating in is too large Recommend using a Dehumidifier with a larger capacity There are too many sourc...

Страница 11: ...ded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guaran...

Страница 12: ......

Отзывы: