background image

Models:

OPERATING INSTRUCTIONS

DEHUMIDIFIER

GDNM10A4BK4AA

GDNM12A4BK4AA
GDNM14A4BK4AA

GDNM10A4BK4CA

GDNM12A4BK4CA
GDNM14A4BK4CA

GDNM10A4BK4BA
GDNM12A4BK4BA
GDNM14A4BK4BA

All the drawings in this manual may be different with the material objects, please refer to the material

 

objects for reference.

Summary of Contents for GDNM10A4BK4AA

Page 1: ...M10A4BK4AA GDNM12A4BK4AA GDNM14A4BK4AA GDNM10A4BK4CA GDNM12A4BK4CA GDNM14A4BK4CA GDNM10A4BK4BA GDNM12A4BK4BA GDNM14A4BK4BA All the drawings in this manual may be different with the material objects please refer to the material objects for reference ...

Page 2: ...FIRST USE to keep it handy for future reference and the date you received the product together with your purchase receipt and attach to the warranty because it contains a cooling agent before use NOTE The rating of this product as marked on the product identification plate is based on specific Do not install and use your dehumidifier before completely reading these instruction 1 Your unit must alw...

Page 3: ...unit is correctly connected before turning on the unit s power Never lay 9 To turn on your unit always use the switch on the control panel 10 Never unplug the dehumidifier while it is working This could damage the electronic circuits 11 Never place anything on top of the unit and do not cover it with any kind of cloth while it is plugged in or in use 12 Do not place objects on the product or allow...

Page 4: ...ration indicator PRODUCT DESCRIPTION Dehumidifier continuously running Continuous Humidity control knob Air filter Bucket Air inlet Tube stopper Air outlet Power supply cord OFF Switch off Handle GDNM10A4BK4AA GDNM12A4BK4AA GDNM14A4BK4AA RUNNING DEFROST FULL CON OFF ...

Page 5: ...TROL PANEL Operation indicator PRODUCT DESCRIPTION Dehumidifier continuously running Continuous Humidity control knob Air filter Bucket Air inlet Tube stopper Air outlet Power supply cord OFF Switch off Handle GDNM10A4BK4BA GDNM12A4BK4BA GDNM14A4BK4BA ...

Page 6: ...TROL PANEL Operation indicator PRODUCT DESCRIPTION Dehumidifier continuously running Continuous Humidity control knob Air filter Bucket Air inlet Tube stopper Air outlet Power supply cord OFF Switch off Handle GDNM10A4BK4CA GDNM12A4BK4CA GDNM14A4BK4CA ...

Page 7: ...e sure the water tank is correctly positioned If switched on remove the tank and replace it NORMAL or CONTINUOUS to work 3 Turn the humidity control knob to the desired setting clogged tically start to defrost and the light will illuminate The defrost lamp will also illuminate if the air filter becomes 4 The unit will shut down when turned to OFF position Replace the bucket carefully before switch...

Page 8: ...n Drainage Hose Is Connected CONTINUOUS DRAINAGE 1 Use a 14mm inner diameter hose Not Supplied for 4 Connect the hose to the drain tap 3 Take out the soft cover put it and tube stopper into uneven surfaces and do not kink the hose permanent drainage the bucket for storage When using continuous drainage the PVC hose must be placed below the drainage hole Avoid ...

Page 9: ...er cleaned every two weeks and more often if the machine operates in a dusty atmosphere The build up of dust reduces the efficiency of the dehumidifier Therefore the air filters must be warm water never use hot or soapy water Make sure that the air filters are completely If the filters are obstructed the dehumidifier will be less efficient Clean the filters with a vacuum cleaner If the filters are...

Page 10: ... cord been twinkles unit can not be started in case operation Discard the water in the drainage The Running lamp disconnected the outlet tank and then reposition the tank above36 Cor below3 C The protection device is actuated and the case please do not use the dehumidifier is under the bad environment in that or disconnected operate The unit does not Is the Red lamp blinking The tank is full or in...

Page 11: ...rs Clean the air filter as instructed obstructed No air is discharged function does not work under Caring for the dehumidifier Is air intake port or discharge port Remove whatever is obstructing the Is the air filter clogged Use the unit in a stable sturdy location Clean the air filter instructed under Operation is noisy Caring for the dehumidifier Is the air filter clogged Has the unit been poorl...

Page 12: ...es abruptly This happens if the temperature and or humidity of the Is the room too big for the unit Are windows or doors The operation noise increases when the compressor Reason When the unit is first used the discharged Very little dehumidifying takes place The humidity do not drop during use or none takes place air smells musty room is low an unusual or musty odor may be produced for a moment Th...

Page 13: ... room with wood flooring or in a small in main unit mode is changed an unusual noise is heard room it may echo stabilizes the factory it does not indicate a problem The fan is running and the compressor If the unit is started within 3 minutes after the unit stops the does not work defrosting operation is activated and the compressor stops automatically after a delay of 3 minutes or the automatic p...

Page 14: ...ommend that you take the following steps Remove water from the water bucket If continuous drainage hose is connected disconnect it Disconnect the unit and wrap the power cord and plug Clean the unit and store it protecting it from dust Store the unit in an upright position Keep it in a cool dry place and away from sunshine ...

Page 15: ...r Clean and Maintenance Take out the healthy filter before cleaning and reinstall it after cleaning according to the installation Clean and Maintenance The healthy filter commonly has its usage lifetime for one year under normal condition As for silver ion filter it is invalid when its surface becomes black green instruction Payspecialattentiontothatsilverionfiltercan tbecleanedwithwater whileacti...

Page 16: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI ADD JINJI WEST ROAD QIANSHAN ZHUHAI GUANGDONG CHINA TEL 0756 8617555 P C 519070 Website http www gree com C GREE 66166505 ...

Reviews: