Thank you for choosing a Goldair Platinum Electronic Dehumidifier. This
Goldair Dehumidifier has been designed and manufactured to high standards
of engineering and with proper use and care, as described in this leaflet, will
give you years of useful service. Please read these instructions carefully.

TECHNICAL SPECIFICATION

Model:

GPDH400

Supply:

230VAC 50Hz

Wattage:

330W

Unit Capacity:

25L/day max (30°C/80%RH)

Tank Capacity:

5.7L

Refrigerant:

R134a/185g

1.

Use only the voltage specified on the rating
label of the appliance.

2.

Keep all objects at least 1 metre from the front,
sides and rear of the appliance. Do not place
appliance close to radiant heat source.

3.

Do not operate in areas where petrol, paint or
other flammable liquids are used or stored.

4.

Do not insert or allow foreign objects to enter
any ventilation or exhaust opening, as this may
cause an electric shock, fire or damage to the
appliance. Do not sit on the appliance.

5.

Do not operate this appliance with a damaged
cord, plug or after the appliance malfunctions or
has been dropped or damaged in any manner.
Return to a qualified electrical person for
examination, electrical service or repair.

6.

This appliance is intended for household use
only and not for commercial or industrial use.

7.

Use this appliance only as described in this
manual. Any other use is not recommended by
the manufacturer and may cause fire, electrical
shock or injury.

8.

The common cause of overheating is deposits
of dust or fluff in the Dehumidifier. Ensure these
deposits are removed regularly by unplugging
the Dehumidifier and vacuum cleaning the air
vents, grills, etc.

9.

Do not use abrasive cleaning products on this
appliance. Clean with a damp cloth (not wet)
rinsed in hot soapy water only. Always remove
plug from the mains supply before cleaning.

10.

Do not connect the appliance to mains supply
until completely assembled and adjusted.

11.

Switch off and use handles provided when
moving.

12.

Do not operate with cord set coiled up as a heat
build up is likely, which could be sufficient to
become a hazard.

13.

It is recommended that this heater is plugged
directly into the wall socket. Power boards are
not rated to supply power to high wattage
appliances.

14.

A correctly specified, undamaged extension
cord may be used with this heater provided it is
used in a safe manner.

15.

Do not remove plug from power socket until the
appliance has been switched off.

16.

Do not remove plug from power socket by
pulling cord; always grip plug.

17.

Always unplug appliance when not in use.

18.

Do not locate the Dehumidifier directly below
any power socket during operation.

19.

Do not twist, kink or wrap the cord around the
appliance, as this may cause the insulation to
weaken and split. Always ensure that all cord
has been removed from any cord storage area
and is unrolled before use.

20.

This appliance is not intended for use by
persons

(including

children)

with

reduced

physical, sensory or mental capabilities or lack
of experience and knowledge, unless they are
supervised or have been given instruction
concerning the use of the appliance by a person
responsible for their safety.

21.

Do not use this appliance in the immediate
surrounds of a bath, a shower, or a swimming
pool or other liquids. The appliance must not be
immersed in any liquids.

22.

When the appliance has been unpacked, check
if for transport damage and ensure all parts
have been delivered. If parts are missing or the
appliance has been damaged, contact the
Goldair Customer Services Team.

23.

If your appliance does not work, or is not
working properly, contact the place of purchase
or the Goldair Customer Services Team. Repair
work on the appliance by unqualified persons
can cause serious risk to the user.

24.

There are no user serviceable parts installed in
the unit.

25.

Do not place the unit in wardrobes or other
enclosed spaces as this may cause a fire
hazard.

26.

This unit is not supposed to be used in or
around locations where foodstuffs, works of art
or delicate articles of science, etc are stored.

27.

Indoor use only.

28.

Children should be supervised to ensure that
they do not play with the appliance.

29.

Ensure Dehumidifier is on a flat, stable, heat-
resistant surface.

30.

It is important that you do not cover this
Dehumidifier.

Содержание GPDH400

Страница 1: ...Platinum Series 25LElectronic Dehumidifier Model GPDH400 Operating Instructions ...

Страница 2: ...ly which could be sufficient to become a hazard 13 It is recommended that this heater is plugged directly into the wall socket Power boards are not rated to supply power to high wattage appliances 14 A correctly specified undamaged extension cord may be used with this heater provided it is used in a safe manner 15 Do not remove plug from power socket until the appliance has been switched off 16 Do...

Страница 3: ...midifier is rated to extract 25L per day in an environment of 80 humidity and temperature of 30 C This is the world wide standard for rating dehumidifiers In New Zealand we do not have climatic conditions with this humidity and high temperature Accordingly the extraction levels may be lower WATER TANK FULL TIMER SETTING AMBIENT HUMIDITY SHOE DRY VENT ...

Страница 4: ...COVER THIS DEHUMIDIFIER MODE Press the MODE button to set the desired mode AUTO TURBO QUIET or FOCUS AUTOMATIC MODE In Automatic Mode when the humidity and temperature sensor detect the ambient humidity is 1 RH less than the set humidity the compressor will stop and the fan will work in Low speed When the ambient humidity is 5 RH more than set humidity the compressor and fan motor will work accord...

Страница 5: ...hen the appliance is running it will automatically restart in the last working mode once power is restored Operating your Dehumidifier FOCUS MODE Press the MODE button to select the Focus mode the air will stop coming out of the front louvres and will come out from the vent on the back of the machine Connect the Y pipe to the vent to allow the dry air to pass through the pipe this is the shoe dryi...

Страница 6: ...st free location preferably covered with a sheet of plastic WATER DRAINAGE When the machine is on and the water tank is full The compressor and the fan will automatically stop working The unit will beep 10 times The Water Full indicator light will turn on Empty the water tank and replace it in the correct position The Dehumidifier will continue dehumidifying when the compressor automatically resta...

Страница 7: ...m is too low It is normal for the Dehumidifier not to operate in low humidity or low temperatures The Dehumidifier operates but reduces the relative humidity in the room by small amounts The room which the Dehumidifier is operating in is too large Recommend using a Dehumidifier with a larger capacity There are too many sources of humidity Recommend using a Dehumidifier with a larger capacity The r...

Страница 8: ...ded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guaran...

Отзывы: