WARNING Keep all objects at least 1 metre from the
front, sides and rear of the appliance.

Ensure all external windows and doors are closed
before turning on the unit.

OPERATION
Leave the appliance to stand for two hours after
transport or after the unit has been on its side before
connecting it to the mains supply to let the refrigerant
settle.
Ensure

that

the

water

container

is

positioned

correctly. Plug into power supply.
Press the POWER button to turn the unit On.
The digital display will show the current ambient
humidity and operating mode.
The current ambient humidity level will be indicated
as follows: Lo

(≤30%RH), from 35% to 75% RH

(Relative

Humidity)

in

5%

increments

and

Hi

(≥80%RH).

SET THE HUMIDITY
Press the HUMID/TIMER button once to set the
desired humidity: the existing humidity setting will
flash on the digital display. Use the Up and Down
buttons to cycle through the settings as follows;
Continuous Operation [CO], from 35% to 75% RH in
5% increments.

The units default humidity setting can be adjusted on
this model. To do this, when the unit is Off, press the
HUMID/TIMER button once, the existing humidity
setting will flash on the digital display. Use the Up and
Down buttons to cycle through the settings as follows;
Continuous Operation [CO], from 35% to 75% RH in
5% increments .

NOTE: When the sensor detects an ambient humidity
level 1% lower than the set level the compressor will
turn off and the fan will continue to run. Once the
ambient humidity level increases to 5% higher than
the set level the compressor will turn back on and
continue to dehumidify.

When the machine is On, press and hold the UP and
Down buttons for 5 seconds, the digital display will
show the ambient room temperature.

IMPORTANT!

NEVER

COVER

THIS

DEHUMIDIFIER

MODE
Press the MODE button to set the desired mode:
AUTO, TURBO, QUIET, or FOCUS.

AUTOMATIC MODE: In Automatic Mode when the
humidity and temperature sensor detect the ambient
humidity is 1%RH less than the set humidity, the
compressor will stop and the fan will work in Low
speed.
When the ambient humidity is 5%RH more than set
humidity, the compressor and fan motor will work
according to the default settings below:
A) When the temperature is lower than 24

and the

set humidity is 60%RH, the fan will operate in Low
speed.
B) When the temperature is between 24-25

and the

set humidity is 55%RH, the fan will operate in
Medium speed.
C) When the temperature is over 25

and the set

humidity is 50%RH, the fan will operate in High
speed.

NOTE: When the unit is set to Automatic Mode the
Humidity will automatically be set and the use of the
Up and Down buttons will not function.

TURBO MODE: Within the continuous dehumidifying
mode you can also increase the fan speed. To do
this, press the MODE button until the

Turbo

flashes

on the electronic display.

QUIET MODE: When quiet mode is selected and the
desired humidity is set, the compressor will stop and
the unit will operate on low speed when the ambient
humidity is 1%RH lower than the set humidity.
When the ambient humidity is 5%RH higher than the
set humidity, the compressor will start and fan will
continue to operate on Low speed.
In quiet mode, press and hold the mode key for 3
seconds for the LED control panel to dim and the
control keys will operate silently.
NOTE: The water tank full beep indicator will not
beep while in silent mode when the water tank is full.

Operating your Dehumidifier

Always choose a safe location for the Dehumidifier, keeping in mind the safety
precautions outlined. Ensure all packaging has been removed from the unit
before use. This appliance requires no installation, it should be used solely as
a portable appliance.

Содержание GPDH400

Страница 1: ...Platinum Series 25LElectronic Dehumidifier Model GPDH400 Operating Instructions ...

Страница 2: ...ly which could be sufficient to become a hazard 13 It is recommended that this heater is plugged directly into the wall socket Power boards are not rated to supply power to high wattage appliances 14 A correctly specified undamaged extension cord may be used with this heater provided it is used in a safe manner 15 Do not remove plug from power socket until the appliance has been switched off 16 Do...

Страница 3: ...midifier is rated to extract 25L per day in an environment of 80 humidity and temperature of 30 C This is the world wide standard for rating dehumidifiers In New Zealand we do not have climatic conditions with this humidity and high temperature Accordingly the extraction levels may be lower WATER TANK FULL TIMER SETTING AMBIENT HUMIDITY SHOE DRY VENT ...

Страница 4: ...COVER THIS DEHUMIDIFIER MODE Press the MODE button to set the desired mode AUTO TURBO QUIET or FOCUS AUTOMATIC MODE In Automatic Mode when the humidity and temperature sensor detect the ambient humidity is 1 RH less than the set humidity the compressor will stop and the fan will work in Low speed When the ambient humidity is 5 RH more than set humidity the compressor and fan motor will work accord...

Страница 5: ...hen the appliance is running it will automatically restart in the last working mode once power is restored Operating your Dehumidifier FOCUS MODE Press the MODE button to select the Focus mode the air will stop coming out of the front louvres and will come out from the vent on the back of the machine Connect the Y pipe to the vent to allow the dry air to pass through the pipe this is the shoe dryi...

Страница 6: ...st free location preferably covered with a sheet of plastic WATER DRAINAGE When the machine is on and the water tank is full The compressor and the fan will automatically stop working The unit will beep 10 times The Water Full indicator light will turn on Empty the water tank and replace it in the correct position The Dehumidifier will continue dehumidifying when the compressor automatically resta...

Страница 7: ...m is too low It is normal for the Dehumidifier not to operate in low humidity or low temperatures The Dehumidifier operates but reduces the relative humidity in the room by small amounts The room which the Dehumidifier is operating in is too large Recommend using a Dehumidifier with a larger capacity There are too many sources of humidity Recommend using a Dehumidifier with a larger capacity The r...

Страница 8: ...ded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guaran...

Отзывы: