Caramatic DriveOne
19 / 36
Installing a gas filter
We recommend installation of a gas filter (Caramatic ConnectClean
part no. 71 781 01) in front of the automatic changeover valve.
LPG may contain foreign matter, such as dirt particles. From a certain size, these particles are
trapped in the filter. If no gas filter is installed, wear and tear of sensitive components is
increased and the complete LPG system may break down.
FUNCTION DESCRIPTION
Safety two stages regulator S2SR
The safety two stages regulator S2SR is a combination of two series-connected pressure
regulators. If one of the two controller stages fails, e.g. because of dirt and other foreign
bodies in the valve, respectively, the other controller stage reduces the pressure to
maximum 150 mbar.
Crash sensor function
Activated crash sensors
Flow rate free
Triggered crash sensors
Flow rate blocked
Operation while driving using the integrated mechanical crash sensor which blocks
the gas flow in case of an accident with deceleration of 3.5 g ± 0.5 g, directly affecting
the trigger element; with an average vehicle weight this corresponds to crashing into
a solid obstacle at about 15 to 20 km/h.
ASSEMBLY
Before assembly, check that the product is complete and has not suffered any damage during
transport.
ASSEMBLY must be carried out by a specialised company.
See USER QUALIFICATION!
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
Consider installation location and installation position (see instructions on INTENDED USE).
Risk of injuries due to blown-out metal chips!
Metal chips may cause eye injuries.
Wear safety goggles!