Main shut-off device type 0271 and type 0272
6 / 10
part no. 02 710 50 a
Outlet,
optional
Trading name and dimensions
acc. to standard
Installation notes
Compression fitting
•
H.8
= Compr. fit. 15, Compr. fit. 18, Compr. fit.
22
Ball-cone connector DN 16
•
H.10 =
Thread G 3/4
•
with coupling nut
Spanner size 32
Hexagonal
Female thread, cylindrical
•
H.7
= Optionally Rp 1/2, Rp 3/4 or Rp 1
For a screw-in
connector with O-
ring
Screw-in connector
•
H.22 =
G 1/2, G 3/4 or G1
For a screw-in connector with O-ring.
Compression/separation connector PTV
•
Thread G 3/4
•
Nominal size optionally 15 mm, 18 mm, 22 mm,
•
H.10
O-Ring muss in
Kerbe liegen.
O-Ring nicht
beschädigen.
1. Loosen coupling nut
2. Remove press connection and press in
with the copper piping
3. Then screw the coupling nut tightly
with the press connection
Assembly in
accordance with
assembly instruction
"Profipress G"
Solder/separation connector LTV
•
H.10
= Thread G 3/4
•
Diameter 18 mm
Spanner sizes
G 3/4 = size 30
Hexagonal
1. Loosen coupling nut
2. Remove solder connection and connect
with the copper piping
3. Screw the coupling nut tightly
with the solder connection
Assembly
according to
DVGW worksheet
GW 2
The G 3/4 coupling nut version can be used only in combination with the GOK
separation connector (e.g. solder/separation connector Type LTV or compression/separation
connector Type PTV).
Alternatively, other connections can be obtained from the manufacturer on
request.