20
4 Programming
English
MENU 2
2.1 Opening and Closing Speed
motor LED colour red:
Option to select 1 of 4 pre-defined speed settings. Default setting is „Normal“.
Note: After 15s. without input, the motor unit quits programming mode.
Please read the steps of this feature first before starting.
1. Press and hold the
OPEN
+
CLOSE
buttons until the LED on the motor unit slowly flash-
es white (after ~8s.) (First the LED will turn white continuously, keep the button(s)
pressed)
2. Repeatedly press
OPEN
or
CLOSE
until the LED on the motor unit is red.
3. Shortly press the
OPEN
+
CLOSE
buttons to enter the feature menu,
4. The LED on the motor unit now flashes red, at the current setting:
5. Cycle through the options below using
OPEN
or
CLOSE:
1x flash
= Normal speed (Default)
2x flash
= High speed
3x flash
= Low speed
4x flash
= Open at low speed - Close at high speed / Custom speed.
6. Confirm and store setting by shortly pressing
OPEN
+
CLOSE
buttons.
7. The LED on the motor unit slowly flashes white again for 15 seconds: using the
OPEN
or
CLOSE
buttons another MENU 2 feature can be selected.
8. Otherwise, wait for 15 seconds or shortly press the
OPEN
+
CLOSE
buttons
to quit
programming.
The LED on the motor unit switches off, the system is ready to use.
To quit programming at any time, repeatedly press the
OPEN
+
CLOSE
buttons
or wait for 15s.
Changes made at 5 will only be saved if confirmed by pressing the
OPEN
+
CLOSE
buttons.
2.2 Intermediate positions
motor LED colour green:
Define up to 5 intermediate curtain stopping positions, in between the systems end posi-
tions. Default is setting is none. Described below for Dry contact.
Intermediate positions can quickly be recalled by pressing 2x
OPEN
or 2x
CLOSE,
within 2s.
The system moves in indicated direction until it reaches next intermediate position.
It is required that at feature 3.1 (p.28) „control mode 1“ is active (default is active).
Note: After 15s. without input, the motor unit quits programming mode.
Please read the steps of this feature first before starting.
Содержание G-Motion
Страница 1: ...G Motion G Motion manual EN 6200 electric curtain track system...
Страница 12: ...8 English...
Страница 16: ...12 English...
Страница 19: ...15 3 English First use auto calibration...
Страница 20: ...16 English...
Страница 40: ...36 B5 86 321 345 14 67 5 42 57 57 40 motor dimens versio G Mot English Technical specifications...