8 Error Messages
Error Message on LCD
Cause/Solution
SUPPLY WATER !
Water Level in Boiler not achieved in 2 minutes, Check water supply
Bend in hose / hose trapped
Scale deposits in water system
HEATING FAILED !
Set Temperature not achieved in 20 Minutes, Water too cold
Check steam protection (service engineer only)
Is the heating element okay? (service engineer only)
SENSOR ERROR !
Check temperature sensor connection (service engineer only)
ENERGY SAVE MODE
Machine idle for more than set hours, Restart Machine
TEMPERATURE LOW
Drink dispensed too fast. ( 4 cups per minute max )
Is the heating element okay? (service engineer only)
Water too cold
WATER LEAKAGE !
Water level too low or no water in the boiler without dispensing a single cup
after the machine was ready
RE-START MACHINE
Prompts in Failure mode. RESTART the machine clears the ERROR and
returns the machine in READY mode
PLEASE TRY AGAIN
PRESS FLAVOR KEY
When Flavour key is pressed and if M/c senses any malfunction in
dispensing flavour, Need to press flavor key again.
By pressing flavor key again and again still machine shows this message
then user defaults needs to be loaded.
WATER LEVEL LOW
Supply water pressure low, drink dispensed too fast
LIMIT ERROR !
During Machine Programming, the value entered is out of acceptable range
MACHINE LOCKED
Lock Counter set number exhausted, reset counter
FLAVOUR LOCKED!
Lock Counter set number for set Flavour exhausted, reset counter
CANISTER# EMPTY
Premix inside Canister (i.e. Channel) is finished, fill it and reset timer
FILL CANISTERS !
All canisters are empty, fill canisters and restart canister timers
KEYPAD SHORT !
One of key or more in the Keypad are short, check keypad
TOKEN /
COIN BLOCKED !
Token is jammed inside token mechanism, check token mechanism
SMARTCARD ERROR!
MDB smartcard module is not connected, check smartcard and its
connections
COINMECH ERROR !
MDB coin mechanism is not connected, check coin mechanism and its
connections
RINSE REQUIRED
Channel is idle for set time, rinse channel
VEND DENIED !
In-sufficient credit, check credit
DRIP TRAY FULL
Drip tray is full with waste water, empty the drip tray
NO DRIP TRAY
Drip tray not inserted, check drip tray
INVALID PASSWORD
Password not matched, re-enter password
PLACE CUP !!
Cup sensor is enabled, sensor not detecting cup presence
REMOVE CUP!!
Cup sensor enabled, remove cup after dispensing beverage
READER SHORT !
Token (Post-paid smartcard) Pay-system is enabled and connection from
reader is short, check smartcard reader
TEA BREWER JAM !
Position sensor does not sense it’s vertical position even after 10sec of
Brewer on, Check connections of the “Brewer position sensor”. Check
brewer is jammed or not.