COMMISSIONING
Check all mountings are secure.
Check all pipework has been connected.
Check engine rotation against PTO rotation.
Ensure drive is connected.
Ensure water is available and connected
Ensure power is available and connected.
Preparation for use
Fill the bearing housing with the specified grade and quantity of oil (see Technical
Data).
Check oil level only when vehicle is stationary and level. If the pump has been running,
allow 5 minutes for the oil to settle.
Figure 22.
If a gear box is fitted, fill with the specified grade and quantity of oil (see Technical
Data). When replacing oil fill/level plugs use Loctite 572 to ensure a good seal, hand
tighten with a suitable spanner.
Figure 23.
Oil filling and level dipstick.
Unscrew to access
Gearbox oil filling points
Gearbox oil level check point
Gearbox oil drain point