29
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the
right to amend specifications without notice or obligation.
When not required the high/low pressure selector lever should be left in the low
pressure position (to the right). This will minimise pump power demand, consume less
fuel and produce less emissions and noise.
Collecting Head Use
If using the factory fitted Godiva collecting head always ensure the collecting head
valves are either fully opened or fully closed depending on the required operational
status. Valves left partially open may inadvertently close in operation due to water
pressure.
Shutdown
Return the pump to idling speed before disengaging the pump drive.
Drain the pump of any water by opening the drain tap at the bottom of the mounting
platform (or at the bottom of the volute if no platform is fitted).