background image

[page 10]  |  gpelectric.com

6. 

GENERATOR NOTE

It is never advisable to start or stop a generator under load. To prolong the life of this transfer switch, and the life of the air 

conditioner, microwave oven, and other appliances, always turn those appliances off before starting or stopping the generator.

7. 

MEDICAL APPLICANCES

Go Power! will not knowingly sell a Go Power! Automatic Transfer Switch for any life-support application. It is strongly 

recommended that you do not operate any life support equipment from a transfer switch. If the switch should malfunction, 

or fail to operate due to other external conditions, it is possible that all connected appliances, including any life support 

equipment, will also shut down, resulting in a risk of medical complications and potential loss of life.

8. 

CAUTION

Do not install this or any electrical accessory in the battery compartment, or a compartment intended for storing 

flammable liquids or liquids, which produce flammable or explosive fumes such as gasoline, etc. There are 

components in the Transfer Switch, which, in their normal operation, may cause arcing. In addition, the act of 

turning on a light switch or unplugging the cord on an electrical appliance can cause a spark, which can ignite 

any combustible liquids or vapors. Therefore, do not install a transfer switch in a compartment intended for storing flammable 

liquids, and never store flammable liquids inside a compartment containing any electrical device.

9. 

WARNINGS

WARNING

: Torque all connections as per instructed on the label. Excessive torque may cause damage to 

connections leading to a fire causing property damage, serious injury, or death.

WARNING: SHOCK HAZARD

 – Due to the high voltages associated with its operation, only qualified service 

personnel should install or troubleshoot this transfer switch. All applicable codes and standards must be met 

when installing this device. See wiring diagram inside of the cover and on the back of this page. Improper 

handling or installation may cause serious injury or death.

WARNING

: The TS-30 transfer switch is not ignition protected and should not be mounted in the same compartment 

as the batteries or flammable materials such as gasoline. Do not mount the transfer switch in the generator or 

LP Gas Compartment. A fire, causing property damage, serious injury, or death could result.

6. GENERATOR NOTE

Note

Содержание GP-TS-30

Страница 1: ...nsfer Switch User Manual GP TS 30 2020 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 MOBI_MAN_GP T...

Страница 2: ...formation size install date battery type Product Packaging Please safely store the packing the IC Series was delivered in or recycle the packaging components as outlined below LDPE Low Density Polyeth...

Страница 3: ...ric com page 3 CONTENTS 1 INTRODUCTION 4 2 INSTALLATION 4 3 OPERATIONAL TESTING 7 4 TROUBLESHOOTING 8 5 HI POT TESTING 9 6 GENERATOR NOTE 10 7 MEDICAL APPLIANCES 10 8 CAUTION 10 9 WARNINGS 10 10 WARRA...

Страница 4: ...mpartment designed for storage of flammable liquids such as gasoline 2 3 ELECTRICAL PREPARATION Any numbered knockout on the TS 30 can be used for installation Choose a knockout that will facilitate i...

Страница 5: ...IONS A B 1 Connect the power cord leads to terminal 7 and 8 on the narrow end of the relay these are the normally closed N C contacts See Diagram 1 on page 6 for numbered locations 2 Connect the gener...

Страница 6: ...allow any other supply to dominate the inverter and the inverter output will pass through the normally closed contacts of the switch This allows the inverter to operate only in the absence of the othe...

Страница 7: ...enerator There is a pre programmed 20 30 second delay in the transfer switch The delay is designed to allow the generator a brief warm up period When the delay completes its cycle the switch should en...

Страница 8: ...o drop out at which point the voltage will rise to the pre in rush level The contacts will chatter when the A C compressor kicks in however the voltage may read normal Most meters are not fast enough...

Страница 9: ...hould be performed from either the transfer switch output or from the main panel Test as follows 1 Turn on all circuit breakers in the panel 2 Make sure the generator is off 3 Make sure the power cord...