Fan Clearance Requirements
Clearances
•
Min 60” center of fan to roof deck for ideal operating performance without compromising
overall fan performance
•
Min 24" from fan blade’s leading edge to obstruction above or below fan
•
Min 18” from side of fan to any obstruction
•
Min 120” floor to fan blade tip or lowest point of the fan
Contractor is responsible for verifying all site conditions to include field dimensions where applicable. If the contractor elects to make
any changes without notifying Go Fan Yourself the contractor is responsible for the same. All drawings are to be used as general
architectural intent unless otherwise stamped. See Engineer drawings for structural design information. Contractor to ensure
that all building departments and authorities are informed in regard to the work and that all permits are attained before
commencing work
.
120"
®
|
3
3
Z-TECH™
FAN
Installation and Technical Operations
®
GO FAN YOURSELF
28"
30"