![GMW TG basic 1 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/gmw/tg-basic-1/tg-basic-1_operating-manual_2236468023.webp)
Operating manual for the TG basic 1 appliance tester
Gilgen, Müller & Weigert
9.2.3. Test assessment
The measurements and their assessments („X“ or „
3
3
3
3
3
“) are
displayed here.
The status bar displays „Test PASS“ or „Test FAIL“ depending on
the result.
Briefly pressing the „START“ button will repeat the test or perform
a new test if a new test object has been connected.
Pressing the „START“ button for longer than 2 s will display the
quick guide.
9.3. Cable test
The cable test allows testing of IEC cables (appliance connection
cables with non-heating device connections), distribution boxes
and extension cables.
Rotary switch position:
The test procedure occurs automatically in the sequence
specified below:
- Measuring the protective conductor resistance
- Measuring the insulation resistance
- Cable test
23