background image

ENG 

 

1.01 

1 0991 497

 

EN

 

-

 

24.03.2017

 

 

5 / 16

 

3010

 

¾”

 

V

ALVE 

M

ANUAL

 

I

NSTALLATION

,

 

U

SE AND 

M

AINTENANCE

 

 

 

 

 

 

needs to be in conformity with the rules applicable in the country in which the installation operates; 
if no rules exist, the qualification can be ensured by a certified EN ISO 9001 quality system 
supplemented if necessary to take into account the specific features of the installation.secondo le 
EN ISO 9001. 

 
 

0.6

 

LIABILITY AND WARRANTY 

 

These instructions are intended for people with experience in installation, adjustment and maintenance of 
hydraulic lifts. 
GMV disclaims any liability for damage caused by improper or different use from what described in these 
instructions or inexperience or carelessness of those responsible to assemble, adjust or repair hydraulic 
components. 
GMV's warranty is voided if you install any components or parts not original, if you make unauthorized changes 
or modifications or made by unauthorized or unqualified personnel. 
 
Unless otherwise indicated, the following situations are forbidden for safety reasons:

 

 

Any product modification; 
The installation of the product for purposes other than those described; 
Damage to the joints; 
Carrying out maintenance or inspections improper or inadequate; 
The use of improper accessories and not original spare parts or materials from GMV. 

0.7

 

WARNINGS BEFORE THE INSTALLATION

 

 

In these instructions the major points concerning the safety and prevention will be marked with the following 
symbols: 

 

 

General warning.

 

 

Warning

 

high risk

 

of danger

Risk of injury

 

(e.g.,

 

crushing,

 

sharp edges, protrusions

etc.

.). 

 

Warning risk of electrical damage (exposed parts).

 

 

Beyond the instruction manual, it should take into account national standards, laws, regulations and other rules 
on accident prevention and environmental protection, and special operating conditions, such as the use of the 
lift, tools and equipment working. 

 

The installation and repair technicians are primarily responsible for their own safety. 
This "Manual" applies to the entire life of the facility, during normal operation, testing and maintenance to be an 
integral part of the system, so it should be kept in a safe place by the installer. 

 

The installation, commissioning and maintenance of the system may only be performed by trained personnel. 
 
Before starting the installation work: 

Use

 

safety devices

 

to protect personnel

 

and

 

prevent falls

Cover

 

(

safely) 

openings in

 

walls and floor

Use the tools and

 

means preventing

 

accidental falls

The gaps

 

should be closed,

 

use

 

appropriate warning

 

signs

Work

 

on electrical equipment

 

must be performed by

 

an electrician

 

or other

 

qualified personnel. 

 

0.8

 

CLEANING AND POLLUTION PROTECTION 

 

Impurities and dirty inside the equipment may cause malfunction of the hydraulic system and premature wear. 
All disassembled items for inspection or repair, as well as pipes and accessories should be thoroughly cleaned 
before re-assembled. 

Содержание 3010

Страница 1: ...ND COMPONENTS FOR LIFTS UNI EN ISO 9001 Certified Company 1 01 ENG English 3010 VALVE SELL TECH WORK CUST USER 3010 VALVE MANUAL INSTALLATION USE AND MAINTENANCE 1 0991 497 EN AVAILABLE WITH TANK TYPE HL HL DRY HL 50 DRY HLV HLV 40 e GL ...

Страница 2: ...3 3 ADJUSTMENT OF THE UPWARD ACCELERATION N 4 10 3 4 ADJUSTMENT OF SLOW LEVELLING SPEED N 2 10 3 5 ADJUSTMENT OF THE UPWARD HIGH SPEED N 8 10 3 6 ADJUSTMENT OF THE DOWNWARD ACCELERATION N 7 10 3 7 ADJUSTMENT OF THE DOWNWARD HIGH SPEED N 9 10 3 8 ADJUSTMENT OF THE UPWARD AND DOWNWARD DECELERATION N 3 10 3 9 PIPE RUPTURE VALVE VC TEST IN THE VALVE BLOCK N 5 11 3 10 ADJUSTMENT OF THE MINIMUM RAM PRES...

Страница 3: ...ressure adjustment 7 Downward start adjustment 8 High speed adjustment 9 Down speed compensator empty full load 10 Hand pump max pressure adjustment 11 Minimum upward pressure adjustment RUB Shut off valve for pressure gauge exclusion MAN Pressure gauge MM Manual lowering button PAM Hand pump V Hand pump air purge screw VP Pilot valve CHK Check valve VMD Downward solenoid valve VML Jump speed sole...

Страница 4: ...the documentation shouldn t be damaged and shouldn t have missing parts Moreover do not tear or deteriorate sheets during consulting 0 3 SAFETY PRECAUTION DURING INSTALLATION WARNING Before starting all kind of installation operation ALWAYS verify that all the safety devices mechanical or electrical are active and working properly 0 4 TOOLING Use standard building yard tooling for the installation...

Страница 5: ...LATION In these instructions the major points concerning the safety and prevention will be marked with the following symbols General warning Warning high risk of danger Risk of injury e g crushing sharp edges protrusions etc Warning risk of electrical damage exposed parts Beyond the instruction manual it should take into account national standards laws regulations and other rules on accident preve...

Страница 6: ...ting the different working procedures and therefore do not take any action without first considering the consequences Make sure that the products received are complete with everything you need and that all products and parts are not damaged during transport Data written on the label should be compared with the order form During the storage period keep the material in the original container protect...

Страница 7: ...Screw for rupture valve test EN 81 20 6 Minimum ram pressure adjustment 7 Downward start adjustment 8 High speed adjustment 9 Down speed compensator empty full load 10 Hand pump max pressure adjustment 11 Minimum upward pressure adjustment RUB Shut off valve for pressure gauge exclusion MAN Pressure gauge MM Manual lowering button PAM Hand pump V Hand pump air purge screw VP Pilot valve CHK Check ...

Страница 8: ... all electrical power by opening the main switch Power wires must be of sufficient section to support the required current and appropriate insulation for the voltage of the mains Wires must not come in contact with hot parts The ground wire should always be connected to the screw marked with the appropriate symbol 2 6 CONNECTION BOX Power units with immersed motor have the motor connection box loc...

Страница 9: ...de the pipe as this may cause a damage to the gaskets seals of the piston and the valves jeopardising the correct functionality of the system Remove the nut and the compression fitting ring from the silencer joint Insert the compression fitting ring as shown in the figure Make sure that the silencer joint is tight Clean and apply a thin layer of oil to the thread and the joint area Insert the tube...

Страница 10: ...DJUSTMENT OF THE UPWARD HIGH SPEED N 8 Start to send the car upward Loosen the lock nut 8 Tighten the screw 8 till you hear the oil returning to the tank then loosen one turn to close Tighten the lock nut 8 The adjustment is finished If needed in those lifts where the speed must be limited for example Home Lift con V 0 15 m s other lifts just gradually tighten the screw 8 to mach the requested spe...

Страница 11: ...ADJUSTMENT OF THE MINIMUM RAM PRESSURE VSMA 2 1 SYSTEMS N 6 Only in installations with traction 2 1 Close the ball valve S Press the manual lowering button MM to release pressure Check the pressure on the manometer MAN is around 6 bar If the pressure it not correct adjust screw 6 The adjustment is finished 3 11 MANUAL LOWERING OPERATION EMERGENCY ONLY BUTTON MM Press the manual lowering button MM ...

Страница 12: ... of the oil 6 Motor protection operation 6 Filters 1 Pressure check 6 Pressure gauge shut off 6 6 Pressure test static pressure x2 6 Ball valve seal 6 Labels signs and schemes 6 Overall check up 5 4 3 MAINTENANCE OPERATIONS What to do Valve gaskets seals At the end of installation and during check ups verify the gasket seals in the following way with the oil at room temperature close the ball valv...

Страница 13: ...se the ball valve S again Continuing with the hand pump reach the desired pressure value controlling with the pressure gauge After the test completely unload the pressure pushing with a screwdriver on the VMD valve Close the pressure gauge exclusion valve Disconnect the hand pump Screw the pressure gauge MAN Ball valve seal Close the ball valve S and open the pressure gauge shut off RUB Fully disc...

Страница 14: ...ward speed is less than the upward speed DEVICES VRF VMD COMPENSATOR VRF Check the adjustment of the screw 8 VMD Check the cleanliness of filters and restrictors SPEED COMPENSATOR Check the perfect sliding of the spool If it s necessary tighten the screw 9 to increase downwards speed The lift only runs at high speed both upward and downward DEVICES VML VRF VML Check that the screw 3 is open Clean ...

Страница 15: ...ENG 1 01 1 0991 497 EN 24 03 2017 15 16 3010 VALVE MANUAL INSTALLATION USE AND MAINTENANCE ...

Страница 16: ...NCE 16 16 Doc n 1 0991 497 Rev 1 00 24 03 2017 File 3010 3_4_10991497EN doc FLUID DYNAMICS EQUIPMENTS AND COMPONENTS FOR LIFTS UNI EN ISO 9001 Certified Company GMV SPA Via Don Gnocchi 10 20016 PERO Milano Italy TEL 39 02 33930 1 FAX 39 02 3390379 http www gmv it e mail info gmv it ...

Отзывы: