2.4
DECELERATION DISTANCES AND SIGNALS
CAR SPEED
V
N
[m/s]
DISTANCE
C-E
UP
[m]
DISTANCE
G-I
DOWN
[m]
0 < 0.15
0.10
0.15
0.10 < 0.15
0.15
0.20
0.16 < 0.30
0.20
0.30
2.5
ELECTRICAL CONNECTIONS
Electrical connections must be performed by qualified and experienced personnel.
Before doing any work is necessary to disconnect all electrical power by opening the main switch.
Power wires must be of sufficient section to support the required current and appropriate insulation for the
voltage of the mains.
Wires must not come in contact with hot parts.
The ground wire should always be connected to the screw marked with the appropriate symbol.
2.6
CONNECTION BOX
Power units with immersed motor have the motor connection box located next to valve block.
Power units with dry motor have the motor connection box located in the motor itself.
2.6.1
POWER UNITS WITH IMMERSED MOTOR
W2
U2
V2
U1
V1
W1
2.6.2
POWER UNITS WITH DRY MOTOR