![GMP Jetstream 89950 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/gmp/jetstream-89950/jetstream-89950_operation-and-maintenance_2236406005.webp)
Page 5
General Machine Products (KT), LLC
GENERAL HYDRAULIC SAFETY INSTRUCTIONS
The GMP Jetstream Cable Blowing Machine has a high pressure hydraulic drive and control system.
Please observe the following precautions when operating the Jetstream Cable Blowing Machine:
-
Always connect the power pack hoses to the Jetstream prior to starting the power pack engine. Failure to
do this may cause severe overheating of the power pack.
Ensure the
‘
on/off
’
control valve on the Jetstream is in the
‘
off
’
position prior to starting the hydraulic power
pack to prevent unwanted operation of the machine.
Always ensure the armoured cable to the hydraulic power pack is connected, this provides an essential
emergency cut off facility.
Escaping fluids under pressure can penetrate the skin and cause serious personal injury. Observe the fol-
lowing precautions to avoid hydraulic hazards:
-
Ensure all hydraulic connections are securely tightened before operating the machine.
Check for leaks with a piece of cardboard.
Do not use your hands!
Do not exceed working pressure of hydraulic hoses.
Visually inspect hoses regularly and replace if damaged.
GENERAL PNEUMATIC SAFETY INSTRUCTIONS
The GMP Jetstream Cable Blowing Machine is a pneumatic device, using pressurised air to project cable
at high velocities. Please observe the following precautions when operating the Cable Blowing Machine:
-
Compressed air can cause flying debris. This could cause personal injury. Always wear personal protec-
tive equipment.
Ensure no personnel are in the manhole at the far end of the cable run. Severe personal injury may result.
Never open the air chamber when pressurised.
Only AUTHORIZED, fully trained personnel should operate the air compressor.
GENERAL ELECTRICAL SAFETY INSTRUCTIONS
The machine has electrical monitoring and safety circuits. Observe the following precautions to avoid elec-
trical hazards:
Do not operate in water. Do not expose the machine to rain.
Always ensure the armoured cable to the hydraulic power pack is connected, this provides an essential
emergency cut off facility.