APPENDIX 2
Crouzet Counter Programming
Programming Parameters
•
Press and hold both
◄
and
►
buttons.
After 5 seconds
‘
ProG
’
will be displayed. Releasing the buttons will display
‘
no
’
•
Press
►
‘
Yes
’
is displayed
•
Hold
◄
and press
►
‘
InPol
’
is displayed
•
Press
►
until
‘
nPn
’
is displayed
•
Hold
◄
and press
►
‘
Filter
’
is displayed
•
Press
►
until
‘
oFF
’
is displayed
•
Hold
◄
and press
►
‘
InPut
’
is displayed
•
Press
►
until
‘
Cnt.dir
’
is displayed
•
Hold
◄
and press
►
‘
FAc.Cnt
’
is displayed
•
Press
◄
•
Enter value
00.0200
for meters,
00.0656
for feet
Use
◄
to move to next digit
Use
►
to increment digit (this instruction applies to all following number inputs)
•
Hold
◄
and press
►
‘
diV.Cnt
’
is displayed
•
Press
◄
•
Enter value 01.0000
•
Hold
◄
and press
►
‘
dP.Cnt
’
is displayed
•
Press
►
until
‘0’
is displayed
•
Hold
◄
and press
►
‘
rES.Cnt
’
is displayed
•
Press
►
until
‘
MAnrE
’
is displayed
•
Hold
◄
and press
►
‘
FAc.tAc
’
is displayed
•
Press
◄
•
Enter value
00.0200
for meters,
00.0656
for feet
•
Hold
◄
and press
►
‘
diV.tAc
’
is displayed
•
Press
◄
•
Enter value 01.0000
•
Hold
◄
and press
►
‘
dP.tAc
’
is displayed
•
Press
►
until
‘0’
is displayed
•
Hold
◄
and press
►
‘
disPm
’
is displayed
•
Press
►
until
‘
Min
-
1
’
is displayed
•
Hold
◄
and press
►
‘
Wait0
’
is displayed