10.0 Procedure for replacing the air box housing seal
Take a length of
ø
2.5mm sealing
material, line it up at the end of the
upper seal groove, and cut it off a
little longer than is necessary
Trim the seal with the end of the
groove each end. Take care not to
damage the seating diameter for the
cable seal and the duct seal. Take
care to make the cut accurately in line
with the end of the groove, the cable
seal and duct seal need to make an
effective seal against the ends of the
housing seal.
Place the pre
-
cut length
in the groove, with some
of the excess length
overhanging each end of
the groove
Repeat the procedure for the lower seal groove and the collet seal grooves in the air box lower and lid as
indicated.
Apply a thin coat of 3M Rubber
and Gasket Adhesive to the top
of the cut sealing material
Spread adhesive along one
side of cord.