background image

 

Technology for safety 

11 

D5000 - D5200 Series 

- Intrinsically Safe Isolators and Safety Relays 

Stripping 
lenght 

7 mm 

Screwdriver for 

Terminal Blocks 

2.5 x 0.4 mm 

Terminal blocks connection data 

Conductor cross section solid 

From 0.2 mm² to 2.5 mm² 

Conductor cross section stranded 

From 0.2 mm² to 2.5 mm² 

Conductor cross section stranded, with ferrule without plastic sleeve 

From 0.25 mm² to 2.5 mm² 

Conductor cross section stranded, with ferrule with plastic sleeve 

From 0.25 mm² to 2.5 mm² 

Conductor cross section AWG 

From 24 to 12 AWG 

Main enclosure terminal block connection data 

Conductor cross section solid 

From 0.14 mm² to 1.5 mm² 

Conductor cross section stranded 

From 0.14 mm² to 1.5 mm² 

Conductor cross section stranded, with ferrule without plastic sleeve 

From 0.25 mm² to 1.5 mm² 

Conductor cross section stranded, with ferrule with plastic sleeve 

From 0.25 mm² to 0.5 mm² 

Conductor cross section AWG 

From 28 to 16 AWG 

Power Bus terminal block connection data  

Stripping 

lenght 

7 mm 

Screwdriver for 

Terminal Blocks 

3.5 x 0.6 mm 

Blue terminal blocks 

on Hazardous Area 

Grey terminal blocks 

on Safe Area 

Содержание D5000 Series

Страница 1: ...00 D5200 Series INSTRUCTION MANUAL INSTRUCTION MANUAL D5 D5000 000 D5200 SERIES D5200 SERIES DIN DIN RAIL POWER BUS RAIL POWER BUS TERMINATION BOARD MOUNTING TERMINATION BOARD MOUNTING INTRINSICALLY S...

Страница 2: ...Main Case Top Cover 9 Transparent Cover 10 Terminal Blocks Connection Data 11 Installation and removing modules from Termination Board 12 Mounting Termination Board 14 Mounting and removing Terminati...

Страница 3: ...connections and instructions Terminal Blocks tagging zone Side D5000 D5200 Enclosure Characteristics High channel density results from innovative circuit design using advanced surface mount components...

Страница 4: ...mounting rail insert a blade screwdriver in the mounting foot and lever against the side of the barrier casing see Fig 3 and Fig 4 To mount Series D5000 D5200 on 35 mm DIN Rail hook one side of the mo...

Страница 5: ...y for safety 5 D5000 D5200 Series Intrinsically Safe Isolators and Safety Relays Fig 6 T35 DIN Rail Dimensions millimeters Fig 4 T35 DIN Rail Pull the module upwards and remove from DIN Rail Fig 5 T35...

Страница 6: ...imum allowed powering capacity is 8 A It is always possible to remove modules without disconnecting the bus connector which remains attached to the DIN Rail Cumulative Fault Alarm indication is provid...

Страница 7: ...he rail by completely rotating both screws clockwise Plug in terminal block male horizontal out for Power Bus MOR022 Power Supply Mounting a plug in terminal block male onto a connector Power Bus Plug...

Страница 8: ...l out for Power Bus MOR022 Plug in terminal block male horizontal out for Power Bus JDFT049 Connector 5 pin Power Bus 12mm DIN Rail JDFT050 Connector 5 pin Power Bus 22mm DIN Rail D5000 Series Mountin...

Страница 9: ...be plugged out by applying a pressure as shown in the picture using a screwdriver Removing Mounting 1 Main case top cover will slide on the enclosure dedicated guides 2 Completely slide main case top...

Страница 10: ...us and fault indication are visible through the transparent cover 3 Close the transparent cover as shown in the picture 1 Open the transparent cover using a screwdriver as shown by arrows in the pictu...

Страница 11: ...stic sleeve From 0 25 mm to 2 5 mm Conductor cross section AWG From 24 to 12 AWG Main enclosure terminal block connection data Conductor cross section solid From 0 14 mm to 1 5 mm Conductor cross sect...

Страница 12: ...mination Board Safe Area connectors Latching mechanism Mounting a module onto a Termination Board 3 Press bottom up the Hazardous Area latch 2 Press bottom up the Safe Area latch Latches position befo...

Страница 13: ...ty 13 D5000 D5200 Series Intrinsically Safe Isolators and Safety Relays Removing a module from Termination Board 1 Unclip the Safe Area latch 2 Unclip the Hazardous Area latch 3 Pull up the module fro...

Страница 14: ...N Rail Mounting Termination Board Nut M4 or M5 Screw M4 or M5 Washer Spacer 10 mm Washer Plate Plate To mount Termination Board on 35 mm DIN Rail hook one side of the mounting foot over the rail s lip...

Страница 15: ...isconnected from the board without disconnecting the power to other boards connected in series Boards are available with custom connectors for any system PLC DCS Supply line 1 Supply line 2 Output con...

Страница 16: ...with the following parameters Temperature 40 to 60 70 C the 45 to 80 C in the data sheet is meant for limited periods mainly to arrange for air transport 10 to 30 C are preferred Humidity 0 to 95 lon...

Страница 17: ...rmal conductivity coefficient K 5 5 for painted steel sheets As an example a cabinet sized 600x600 mm and 2000 mm high has a temperature rise of 10 C for an installed power of 250 W 2 Open Cabinets wi...

Страница 18: ...xample 4 Forced air circulation via heat exchanger air circulation by two separate flows internal and external 1000 W Example 2 Air flow Natural convection 350 450 W Example 3 Air flow filtered fans 5...

Страница 19: ...1 A3 A1 A3 A1 A3 A1 A3 A1 A3 A1 A3 A1 A2 A3 A1 A2 A3 ATOT 2 x A1 2 x A2 A3 Formula for cabinet with no surfaces in contact with the wall ATOT 2 x N x A1 2 x A2 N x A3 N Number of cabinets placed side...

Страница 20: ...r part of the cabinet 4 If you apply ventilation please consider the following a When applying temperature control you have to install the temperature sensor in the upper part of the cabinet b It is m...

Отзывы: