background image

Prioridad de seguridad

Fig. 2

Fig. 1

Posit.        P

Safety priority

Prioridad de servicio

Fig. 1

Fig. 2

Negat.      

N

Service priority

A1

1

2

earth

L1

1

2

A2

L2 L3 N

14

12

10

tierra

D30

C

CT-1

A1

1

2

earth

L1

1

2

A2

L2 L3 N

14

12

10

tierra

D30

C

CT-1

U

s

 = 0

Normal

Disparado
Tripped

Lógica disparo / Logic trip

Pos.

Neg.

14

10

12

14

10

12

14

10

12

14

10

12

14

10

12

14

10

12

U

s

 = 0

Normal

Disparado
Tripped

Lógica disparo / Logic trip

Pos.

Neg.

14

10

12

14

10

12

14

10

12

14

10

12

14

10

12

14

10

12

• RELÉ DIFERENCIAL DE FALLOS A TIERRA

D30

• EARTH FAULT DIFFERENTIAL RELAY

Dimensiones / Dimensions

100

80

72,6

22,4

61,5

8

7

6
5
4
3

2

9

10

11 12

13

1

*

El relé supervisa permanentemente el circuito toroidal-relé, si este se
interrumpe el relé dispara y enciende de forma intermitente el LED rojo.

**

El equipo dispone de doble circuito de medida lo que le confiere una
seguridad redundante. Si uno de estos circuitos se averiase el relé
seguiría midiendo correctamente por el otro. Esta situación es detectada
por la función auto-diagnostico de que dispone y señalizada mediante el
parpadeo del LED verde ON. Cuando se de esta improbable situación es
aconsejable sustituir el relé cuando sea posible. 

INSTRUCCIONES DE SEGURIDAD

• Para evitar descargas eléctricas durante la instalación o manipulación del

relé, asegúrese de que no hay tensión en la línea ni tensión auxiliar.

• Comprobar que la tensión nominal es la correcta. 

ESQUEMA DE CONEXIONES

• Cableado: Los esquemas se representan con el relé sin tensión de

alimentación conectada.

• Conectar el dispositivo de disparo (bobina de emisión, bobina de mínima,

contactor, etc.) según el siguiente cuadro.

Contactos de salida

Bornas conexión transformador
toroidal CT-1

Botón de rearme

Botón de prueba

Ajuste sensibilidad 

I

n

Ajuste del tiempo de retardo

LED rojo 

LED verde 

Alimentación

Tipo de rearme

Selección lógica de disparo

Factor multiplicador de sensibilidad

Selección frecuencia de la red

*

The relay constantly supervises the toroidal circuit-relay. Should this
become interrupted the relay trips and the red LED begins to flash. 

**

The unit is equipped with a double measuring circuit providing
redundant safety. Should one of these circuits fail, the relay shall continue
measuring correctly via the other one. This situation is detected by its
self-diagnosis function and is signalled by means of the flashing green
LED ON. Should this improbable situation occur it is advisable to replace
the relay as soon as possible. 

SAFETY INSTRUCTIONS

• To prevent electric discharges during the installation or handling of the

relay, ensure there is no voltage in the line and no auxiliary voltage.

• Check that the nominal voltage is correct. 

CONNECTION DIAGRAM              

• Wiring: The schematics show the relay with supply voltage disconnected.  

• Connect the trip device (shunt trip coil, undervoltage trip coil, contactor,

etc.) according to the following table.

A

B

B

A

Bobina de mínima
Contactor

C

Bobina de emisión

Lógica de disparo

Undervoltage trip coil
Contactor

Shunt trip coil

Logic trip

Fig. 1

Fig. 2

2

1

Output contacts

Connection terminals for toroidal
transformer CT-1

Reset push-button

Test push-button

Sensitivity adjustment 

I

n

Delay time adjustment

Red LED 

Green LED 

Supply

Reset type

Logic trip selection

Sensitivity multiplier factor

Network frequency selection