- 1 -
Electronic bistable pulse relay BIS-412M is designed to work in
a group system. The single relay allows you to control the re-
ceiver using momentary (bell) buttons, connected to local con-
trol inputs. Additionally, thanks to the central control inputs, it
is possible to group control of many receivers simultaneously.
The lighting of the green LED marked with the U symbol means
that the device is properly powered. The device can be control-
led from the level of local and central inputs.
Local control
The receiver is turned on (the relay contact is switched to po-
sition 7-10) after pressing any momentary button from the local
control group. The activation of the receiver is signaled by the
lighting of the red LED diode. Another pressing of the button
from the local control group will turn off the receiver (the con-
tact returns to position 7-12).
Purpose
Functioning
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: [email protected]
Do not dispose of this device in the trash along with other waste!
According to the Law on
Waste, electro coming from households free of charge and can give any amount to up to
that end point of collec� on, as well as to store the occasion of the purchase of new equip-
ment (in accordance with the principle of old-for-new, regardless of brand). Electro thrown
in the trash or abandoned in nature, pose a threat to the environment and human health.
BIS-412M
24V
Bistable relay (group) with
„memory” contact position