different battery types. Press “OK” to finish this setting and you will enter the setting interface as
shown in Figure 37.
4.1.5.7 Setting Battery Maximum Charging Current
WAIT
KW
KW
KW
KW
KW
KWh
INVERTER EXPERT
EOUT
Ic
A
Figure 37 Battery maximum charging current setting
Ic refers to the maximum charging current with setting range from 5A to 50A. The default value is
50A. Please set this current value according to the battery recommended value of different
battery types. Press “OK” to finish this setting and you will enter the setting interface as shown in
Figure 38.
4.1.5.8 Setting Grid Certification Standards
WAIT
KW
KW
KW
KW
KW
KWh
INVERTER EXPERT
EOUT
CER
Figure 38 Grid certification standards setting
CER refers to the grid regulation where this system is applied in. The CER codes mean: 00 , 01, 02
respectively refer to comply with the G83/2 in the UK, the VDE AR-N 4105 in the Germany and
AS4777 in Australia.The default CER code is 01 for German standard. Please finish this setting