background image

Global Mainstream Dynamic Energy Technology Ltd.                                                 

 

 

- 31 -

 

User Manual   
GHESS 3.7-4.8-SL hybrid system 
 

setting interface as shown in Figure 35. 

4.1.5.5 Setting Battery Discharging Cut-off Voltage 

WAIT

KW

KW

KW

KW

KW

KWh

INVERTER EXPERT

EOUT 

BVL

V

 

Figure 35    Battery discharging cut-off voltage setting 

 

BVL refers to battery discharging cut-off voltage with setting range from 40V to 60V. Default BVL 
value is 44V for lithium battery and 47V for lead-acid battery. Please set the voltage according 
to the battery recommended value for different battery types. 
Press “OK” to modify the value and please make sure the BVL value input is smaller than the BVH 
value in 4.1.5.4. Press “OK” to finish this setting and you will enter the setting interface as shown in 
Figure 36.   

4.1.5.6 Setting Maximum Discharging Current 

     50

8.8.8

8.8.8

8.8.8

8.8.8

8.8.8

8.8.8.8

2088-08-

88

88:88

WAIT

KW

KW

K

W

KW

KW

KW

h

INVERTER EXPERT

EOU

Id

A

 

Figure 36    Maximum discharging current setting 

 

Id  refers  to  the  maximum  discharging  current  with  setting  range  from  5A  to  50A.  The  default 
value  is  50A.  Please  set  this  current  value  according  to  the  battery  recommended  value  of 

Содержание GHESS 3.7-4.8-SL

Страница 1: ...User Manual 1 Phase Residential Energy Storage System For GHESS 3 7 4 8 SL...

Страница 2: ...2 Description 8 2 1 General System Description 8 2 2 System Connection 10 3 System installation 10 3 1 Unpacking the Device 11 3 1 1 Before Unpacking 11 3 1 2 Mounting 11 3 1 3 Packing List 13 3 2 Mo...

Страница 3: ...4 2 Wi Fi 38 4 2 1 Wi Fi Function 38 4 2 2 Wi Fi Configuration 39 5 System Operation 42 5 1 System Settings 42 5 2 System Starting 42 5 3 System Operating Instructions 43 5 3 1 On grid Operation 43 5...

Страница 4: ...21 60710806 service global mde com Legal Disclaimer All information in this documentation has been compiled and checked with most care Despite of this errors or deviations cannot be completely exclude...

Страница 5: ...of the manual please note that you can click the content to find information you want quickly All the characters with underline are clickable A phrase named Back to Top at the bottom of each chapter...

Страница 6: ...jury will occur Warning Death or severe personal injury may occur Caution Personal injury or material damage may occur Explanations Electric Shock Do not open the device Dangerous voltage may still be...

Страница 7: ...e follow the steps described in this manual Disconnecting the product Please refer to Disconnecting for maintenance in Section 5 4 System Maintenance Note that after disconnecting the hybrid inverter...

Страница 8: ...restriction any economic losses of any kind any loss or damage to property any personal injury any damage or injury arising from or as a result of misuse or abuse or the incorrect installation integra...

Страница 9: ...ts the DC power generated by PV modules into AC power The generated electricity from PV is used by the household loads charged into the battery packs or fed into the grid B Battery packs Battery packs...

Страница 10: ...if users need to switch to off grid function manually by disconnecting it please refer to Figure 4 PV1 PV2 GRID LOAD WIFI CAN RS485 Ethernet BAT Distribution box L N SET Single Energy Meter L N L N 5...

Страница 11: ...lation of the devices 3 1 2 Mounting 1 Don t install the device in direct sunshine External heating from exposure to the sun may cause excessive internal heating This may result in output power being...

Страница 12: ...3700TL dimension 600 245 500 Battery Pack To Inverter To Meter To Meter DC BREAKER To Inverter To Cabinet Figure 6 Battery cabinet dimension Module Powervortex 3700TL Battery Cabinet Dimension L W D 5...

Страница 13: ...660 0 500 0 300 300 200 200 170 0 245 0 Figure 7 Installation space 3 1 3 Packing List 3 1 3 1 Powervortex 3700TL Packing List A2 A3 A4 User Manual A1 A5 A6 A7 Figure 8 Powervortex 3700TL packing lis...

Страница 14: ...3700TL packing list 3 1 3 2 Unpacking Battery Cabinet B2 B1 B3 B4 Figure 9 Battery cabinet packing list Item Description pcs B1 Battery cabinet 1 B2 Battery cabinet mounting bracket 1 B3 Expansion Tub...

Страница 15: ...rvortex 3700TL and battery packs 1 D5 Battery parallel connection communication cable 1 D6 Battery positive power cable 1 D7 Battery negative power cable 1 Table 5 Accessories box packing list 3 2 Mou...

Страница 16: ...g on the hook of wall bracket A2 9 Check if Powervortex 3700TL A1 is properly fixed on the wall Installation demonstration Figure 12 Powervortex 3700TL installation demonstration 3 2 2 Mounting Batter...

Страница 17: ...ll holes on marked position 3 Fix the expansion bolt B3 in the hole 4 Fix wall bracket B2 on the wall 5 Fix screw B4 through wall bracket B2 to expansion bolt B3 adjust the bracket position and screw...

Страница 18: ...AD D CAN RS485 Link Port0 Link Port1 POWE R ON OFF IN COM1 COM3 NO1 NO2 NO3 GND SW POWE R ON OFF AD D RUN RUN Console Console SOC ALM RS485 CAN Link Port1 Link Port0 IN GND NO1 COM1 NO2 COM2 NO3 Cabin...

Страница 19: ...ink Port1 POWE R ON OFF IN COM1 COM3 NO1 NO2 NO3 GND SW POWE R ON OFF AD D RUN RUN Console Console SOC ALM RS485 CAN Link Port1 Link Port0 IN GND NO1 COM1 NO2 COM2 NO3 Cabinet 2 D6 D7 D5 RS485 3 4 To...

Страница 20: ...Load Grid SET Single Energy Meter L N L N 5 6 7 8 Battery Pack Battery Pack Battery Pack Grid Figure 18 Meter position Please pay attention to the direction of Energy meter L N port on the meter is to...

Страница 21: ...is disconnected before installation Caution The maximum current stand by energy meter is 20A Caution A standard AC breaker should be installed after the GRID port of the inverter Table 6 Warning 3 3...

Страница 22: ...on for PV connector grid connector and emergency load connector Please choose the proper wire AWG12 recommended to make different connectors according to the length of connecting line Figure 22 PV con...

Страница 23: ...on 3 3 3 System Connection Please refer to table below and connect the power lines communication lines with correspond ports on the device respectively Item Line Illustration Illustration 1 To Meter D...

Страница 24: ...Connection line and corresponding ports list 3 3 4 9 6kWhSystem Connection The connection difference between 9 6kWh and 4 8kWh system are listed as below 1 Change the D3 line Item 4 listed in Table 8...

Страница 25: ...To Meter DC BREAKER To Inerter To Cabinet To Meter DC BREAKER To Inerter To Cabinet Figure 27 9 6kWh system power line connecting 4 System Settings 4 1 LCD 4 1 1 LCD Interface All information related...

Страница 26: ...ht Light on if the communication between PV inverter and Battery manger is fine WiFi operation light Light on when the WiFi is running Warning light Light on when system warning happens Table 10 LCD s...

Страница 27: ...Voltage Current AC GRID voltage on grid GRID voltage on grid EMERGENCY LOAD voltage off grid EMERGENCY LOAD current off grid TEM Soldate3700TLtemperature BM024temperature FRE Grid frequency ET1 Daily...

Страница 28: ...ill be displayed WAIT KW KW KW KW KW KWh INVERTER EXPERT EOUT PV1 Figure 30 Display menu Id Max discharging current default 50A Ic Max charging current default 50A CER Certification 00 G83 default 01...

Страница 29: ...me setting as Figure 32 showed and choose different information by pressing buttons Users can press ESC button to quit from setting and enter into the display menu 4 1 5 2 Setting Time WAIT KW KW KW K...

Страница 30: ...Press OK to finish the setting and you will enter the setting interface as shown in Figure 34 4 1 5 4 Setting Battery Charging Cut off Voltage WAIT KW KW KW KW KW KWh INVERTER EXPERT EOUT BVH V Figur...

Страница 31: ...oltage according to the battery recommended value for different battery types Press OK to modify the value and please make sure the BVL value input is smaller than the BVH value in 4 1 5 4 Press OK to...

Страница 32: ...The default value is 50A Please set this current value according to the battery recommended value of different battery types Press OK to finish this setting and you will enter the setting interface as...

Страница 33: ...ted with PV string the CNY should be set to 02 when Powervortex 3700TL only have PV2 port connected with PV string the CNY should be set to 03 when Powervortex 3700TL PV1 and PV2 ports are connecting...

Страница 34: ...et the digits on figure 43 as 22 00 05 00 respectively The charging current is the same as the Ic that has been set in Section 4 1 5 7 Press OK to enter into the discharging time range setting interfa...

Страница 35: ...you will enter the setting interface as shown in Figure 44 WAIT KW KW KW KW KW KWh INVERTER EXPERT EOUT ADR Figure 44 Energy meter address setting ADR refers to energy meter address Please check the a...

Страница 36: ...right ratio The default value is 01 it s not necessary to modify this value if no current tranformer is connected in 4 1 5 13 Setting Lithium ion BMS Code Press OK to finish this setting and you will...

Страница 37: ...y is reduced to 20 The SOC default value is 20 please press OK to modify it 4 1 5 15 Setting Feed in Grid Percentage WAIT KW KW KW KW KW KWh INVERTER EXPERT EOUT FED Figure 48 Feed in grid percentage...

Страница 38: ...enu Note The setting should be operated when the Powervortex3700TL is under wait status otherwise the E05 error might occur to the system 4 2 Wi Fi 4 2 1 Wi Fi Function Powervortex3100 3700TL solar ba...

Страница 39: ...3700TL Wi Fi network Note in this step above the most important thing is to power on the inverter and find out the Wi Fi generated by the inverter from the WLAN options page on your Mobile Ipad comput...

Страница 40: ...put MDE as MDE is the Wi Fi Name in our office and be input as an example Save your setting and restart wait at least 2 minutes If the device IP address is no longer 0 0 0 0 then the device is connect...

Страница 41: ...mail address and monitor SN Please notice the Monitor SN is the Suffix of the GMDE_XXXXXXXX For example if the Wi Fi of one device is GMDE_3E227BB2 then the Monitor SN you should key in is 3E227BB2 F...

Страница 42: ...LCD lighting on users can set parameters including password time battery type county code and operation mode etc For details please refer to section 4 1 5 LCD Setting Turn off the DC switch optional w...

Страница 43: ...icient PV energy the system discharges the battery pack first if PV power and battery discharging power is smaller than the load power then the grid co supply energy to the load 2 Time of Use Mode Pea...

Страница 44: ...ntil the capacitors have fully discharged Discharge takes around15 minutes Caution Danger from inadequate grounding An inadequate grounding conductor connection can cause serious injuries to persons a...

Страница 45: ...Temp Warning E17 Consistent Volt E18 Consistent Dci E20 Bus Soft Time out E21 Inv Soft Time out E22 Bus Low Warning E23 Bus High Warning E24 Consistent Freq E25 Pv Boost Over Curr Warning E26 Bat Over...

Страница 46: ...ment After shutdown due to a fault the device remains locked against reactivation until the fault is acknowledged The fault can only be acknowledged after the cause of the fault has been eliminated To...

Отзывы: