Environmental requirements
Provide a heating and ventilating system capable of maintaining room temperature be-
tween 20 and 30°C (68 and 86°F) and relative humidity on max. 40-80%.
#
The ventilating system must be capable of renewing the air around the
processor effectively. The best solution will be a hood with a Ø100-120 mm
exhaust hose covering the exit of the processor with a capacity of removing
min. 300 m
3
/h. Alternatively an exhaust system removing the air from the room
must have a capacity of min. 800 m
3
/h. In both cases fresh air should be
provided at floor level through light tight ventilation openings.
Be aware that the airflow must pass from the setter and across the processor -
never
the opposite way around.
Tightening the brushes
During transport all brushes have been released from their normal working points.
Before commencing please tighten the brush pressure screws
1 full turn
(see illustra-
tion).
"
Before processing start, it is recommended to check the brush pressure
according to the description in the “Service Manual”.
1049
Installation Manual - Plate Processor 150
2-23
Installation
Preparation for processing
T 31353
1 full turn
Содержание Plate Processor 150
Страница 1: ...Installation Manual Plate Processor 150 ...
Страница 2: ......
Страница 6: ...Installation Manual Plate Processor 150 1049 0 4 ...
Страница 17: ...1049 Installation Manual Plate Processor 150 2 9 Installation Lifting Transporting 6 5 3 1 2 3 6 4 T 31662 ...
Страница 33: ...1049 Installation Manual Plate Processor 150 2 25 Installation Preparation for processing T31666 3 1 2 ...
Страница 35: ...1049 Installation Manual Plate Processor 150 2 27 Installation Preparation for processing 1 2 3 4 T31667 ...