Installation requirements for power supply
The table below indicates the applicable power supply types and recommended cable
types and which processor models they apply to:
Supply / Fuse
Recom. Cable type
150
EUR
1W + N + PE, 230 VAC,
1 x 25 A, 50/60 Hz.
Min. 3 x 2.5 mm²,
type H07RNF
·
3W + N + PE, 400 VAC,
3 x 15 A, 50/60 Hz.
Min. 5 x 2.5 mm²,
type H07RNF
·
US
2W + PE, 230 VAC,
2 x 25 A, 50/60 Hz.
Min. 3 x 12 AWG,
type SJO
·
3W + PE, 230 VAC,
3 x 20 A, 50/60 Hz.
Min. 4 x 12 AWG,
type SJO
·
JAP
2W + PE, 200 VAC,
2 x 25 A, 50/60 Hz.
Min. 3 x 12 AWG,
type SJO
·
3W + PE, 200 VAC,
3 x 20 A, 50/60 Hz.
Min. 4 x 12 AWG,
type SJO
·
Max power consumption
150
EUR/
US
230/400 VAC operation:
5,100 Watt / 17,400 BTU/hour
·
Stand-by:
Approx. 500 Watt / 1,710 BTU/hour
·
JAP
200 VAC operation:
3,900 Watt / 17,400 BTU/hour
·
Stand-by:
Approx. 500 Watt / 1,710 BTU/hour
·
All
Voltage tolerance ± 10%
·
1049
Installation Manual - Plate Processor 150
2-11
Installation
Electrical specifications
Содержание Plate Processor 150
Страница 1: ...Installation Manual Plate Processor 150 ...
Страница 2: ......
Страница 6: ...Installation Manual Plate Processor 150 1049 0 4 ...
Страница 17: ...1049 Installation Manual Plate Processor 150 2 9 Installation Lifting Transporting 6 5 3 1 2 3 6 4 T 31662 ...
Страница 33: ...1049 Installation Manual Plate Processor 150 2 25 Installation Preparation for processing T31666 3 1 2 ...
Страница 35: ...1049 Installation Manual Plate Processor 150 2 27 Installation Preparation for processing 1 2 3 4 T31667 ...