3.10.11 Correction of faults
(EFLG)
EFLG
(Function available for authorized persons only)
3.11 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes
after having switched off (lamp too hot). The message will appear on
the display if the lamp doesn’t ignite within 20 seconds. The fixture will
store this command and automatically ignite the lamp after 5 minutes.
IG E
When igniting the lamp, the electronic ballast will examine whether the
lamp ignited or not. If the lamp does not ignite within 20 seconds, the
igniting sequence is broken off. Now approx. 2 minutes are waited, until
a renewed ignition attempt is started automatically. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped and
the display reads "
IG E
" (Ignition error).
LAER
As soon as the lamp ignited correctly, the lamp current is constantly
supervised by the system. If an interruption steps on (covers opened or
lamp damaged), the power is switched off immediately. The display
reads "
LAER
" (lamps error). Please switch off the power supply and
solve the possible problem.
After an error like "
IG E
" respectively "
LAER
" it is not anymore possible the start
the lamp via Shutter = 255. Nevertheless if a renewed ignition attempt is desired,
first run a Reset (at the Spot or over DMX). Afterwards you can try again to ignite
the lamp.
OTMP
This error message informs you that the fixture was overheating and
that the relay switches off the lamp. Pleas look for possible reasons
(fan faulty, air in/outlets blocked or very dirty, lamp broken or very old,
too high ambient temperature. Switch off the power supply and solve
the possible problem.
RsER
This message informs you that one of the fixture function wasn’t able to
do its reset correct (magnetic sensor, stepping motor, driver on the
PCB, cables, etc.). Repair the defect and start the fixture again.