mended, under no circumstances should alcohol or solvents be used!
The inside optical system should be maintained only by authorized persons. Please
contact your local dealer.
6.1 Safety
Regulations
•
Pull out the main plug!
•
Wait min. 20 minutes after the last operation to cool down the fixture.
•
Before you put the
Y
Y
P
P
O
O
C
C
5
5
7
7
5
5
C
C
O
O
L
L
O
O
R
R
into operation close the casing,
otherwise your retina can be hurt!
6.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Therefore
no general guidelines can be given. From this it follows that the intervals are only
suggestions from our practice experience.
Position
Interval
In this way
Outside optic
weekly
soft cloth and glass cleaning fluid
Color filter
monthly
soft cloth and glass cleaning fluid
Beam shape
monthly
soft cloth and glass cleaning fluid
Dimmer/Shutter
yearly
vacuum cleaner, airbrush, etc.
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Reflector
never
Lamp
never
Moveable parts
yearly
suitable fatty oil
Attention:
•
Never let optical parts come into contact with oil or grease.
•
Before running the fixture wait until all parts are dried up.
6.3 Cleaning the Optical System
1. Pull out the main plug!
2. Wait min. 20 minutes after the last operation to cool down the fixture.
3. Open the upper shell of the head casing by loosening the 4 Phillips screws.
Two on the front side and two on the back side of the head.
4. Do the work as explained in the list above.