7 Technical 

Specification 

Mains supply 
Power consumption 

~90 - 260V, 50 - 60 Hz 
780 Watt, 3.8A, electronic ballast, (blind current compensated) 

Fuse protection 

Lamp: T 5A, 250V, 5x20 mm (fine-wire fuse) 
Electronic: T 1A, 250V, 5x20 mm (fine-wire fuse) 

Lamp 
Type 

HTI 575-DE (OSRAM) 

Live time 

500h (750h) 

Color temperature 

5600k or 7500k 

luminous flux 

43.000 lm 

Optical system 

Glass reflector 
Fresnell lens 150mm  

Color 

9 dichroic filter plus white plus 1x CTC 5600k, 1x CTC 3300k 

Beam shape 

Step less Beam shape 

Frost filter 

Motor driven focus from near to far away 

Zoom: Motor driven variable angle of reflected beam from  8° to 22° 
Shutter / Strobe / Dimmer 

Strobe- effect with variable speed 1 - 10 flashes per second

 

Continuously mechanical dimmer 0 - 100% 

Drive 

Standard DMX-512, 3 pole XLR; [+] = Pin 3    [-] = Pin 2    [Ground] = Pin 1.  
The DMX- addressing starts at the DMX- address [001]. 

Pan / Tilt 
Pan- movement 

530° in max. 2,65 seconds, 16 bit resolution 

Tilt- movement 

280° in max. 1,68 seconds, 16 bit resolution 

Weights and measures 
Width of the base 

380 mm 

Length of the base 

390 mm 

height (head vertical) 

520 mm 

Weight (net) 

19 kg 

 

 

Содержание YPOC 575 COLOR

Страница 1: ...Instruction Manual from software version 1 0 instruction version 1 0 e mail service glp de Internet http www GLP de...

Страница 2: ...GLP German Light Production 1 0 2 This side is intentionally unlabelled...

Страница 3: ...3 5 Reset RESE 12 3 6 Running time of lamp and unit TIME 12 3 7 Continuous Color Wheel FCOL 13 3 8 Invert Pan Movement RPAN 13 3 9 Invert Tilt Movement RTLT 13 3 10 Special Functions SPEC 13 3 10 1 Ma...

Страница 4: ...egulations 21 5 2 Realize the Lamp Change 21 6 Maintenance and Cleaning the Y YP PO OC C 5 57 75 5 C CO OL LO OR R 21 6 1 Safety Regulations 22 6 2 Circumference and Interval rule of thumb 22 6 3 Clea...

Страница 5: ...X OUT So ftwa re Upd ate 1 Ground 2 Data 3 Data Mic Sensitivity 6 7 8 9 10 15 6 Software Update connector 7 Microphone Intensity 8 DMX Input 9 DMX Output 10 Fan air inlet outlet 11 Power On Off 12 Mai...

Страница 6: ...open the Y YP PO OC C 5 57 75 5 C CO OL LO OR R Please do not touch the bulb of the lamp if you are not absolutely sure it is cold Danger of BURNING 5 Never look directly into the beam of the lamp Yo...

Страница 7: ...handles for secondary attachment Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation should be done by qualified staff only 2 1 1 Clamps There are two major...

Страница 8: ...7 75 5 C CO OL LO OR R to mount the unit on a truss each two opposite threads max M10x20 4x M10x20mm 4x Camlock 2 2 Secure the Y YP PO OC C 5 57 75 5 C CO OL LO OR R Regardless of the rigging of the Y...

Страница 9: ...rd input output See also printing on the case for the right pin assignment Pin 3 Pin 2 Ground Pin 1 The DMX Addressing starts at the DMX Address 001 2 4 Fuses The Y YP PO OC C 5 57 75 5 C CO OL LO OR...

Страница 10: ...OC C 5 57 75 5 C CO OL LO OR R RESE Reset TIME POWR Running time of the fixture no destructible LA1 Running time of the lamp erasable LA2 Running time of the lamp no destructible FCOL Reverse Pan dire...

Страница 11: ...LO OR R and wait until the fixture reset has finished RESE is flashing in the display 2 Press the Mode key in order to access the main menu Browse through the menu by pressing the Up Down keys until...

Страница 12: ...io function is only working if no DMX is connected This function can work e g on small events or as an emergency program 3 4 Lamp On Off LAMP LAMP Use the Up Down keys to select lamp On or lamp Off Pr...

Страница 13: ...you to invert the Tilt movement Use the Up Down keys to select invert On or Off Press Enter to confirm or Mode to cancel 3 10 Special Functions SPEC SPEC This menu allows you to enter further special...

Страница 14: ...to confirm or Mode to cancel and return to the menu If you have chosen off you have the possibility to start the lamp either via DMX or direct at the Y YP PO OC C 5 57 75 5 C CO OL LO OR R in the Lamp...

Страница 15: ...ction and press Enter to confirm or Mode to cancel and return to the menu D ON Display On Off If you ve chosen off the display will go out within 15 seconds after the last input The next key touch wil...

Страница 16: ...nel DMX value 224 229 This will last until a temperature of 90 is reached 3 10 8 Adjustments and Calibrations ADJU ADJU With this function you can adjust and calibrate the positions of the different w...

Страница 17: ...ttings DFSE DFSE Press Enter to reset all fixture personalities not the adjusted functions to the default values The display will read ok to indicate that the defaults are set Function Display Default...

Страница 18: ...n as the lamp ignited correctly the lamp current is constantly supervised by the system If an interruption steps on covers opened or lamp damaged the power is switched off immediately The display read...

Страница 19: ...76 79 4C 4F 30 0 color 4 Pink slow 80 83 50 53 31 6 color 5 Orange slow 84 87 54 57 33 1 color 6 Italian Blue slow 88 91 58 5B 34 7 color 7 Turquoise slow 92 95 5C 5F 36 3 color 8 Jade slow 96 99 60 6...

Страница 20: ...0 14 15 0E 0F 5 7 PAN 3 0 16 17 11 11 6 5 3 90 18 19 12 13 7 3 3 180 20 21 14 15 8 0 3 270 22 23 16 17 8 8 PAN 4 0 24 25 18 19 9 6 4 90 26 27 1A 1B 10 4 4 180 28 29 1C 1D 11 2 4 270 30 31 1E 1F 12 TIL...

Страница 21: ...wo sidewise lamp screws Attention The glass bulb of the lamp can splinter For that reason remove the lamp with safety gloves or some cloth 5 Put in the new lamp securely with a tight fit into the sock...

Страница 22: ...is way Outside optic weekly soft cloth and glass cleaning fluid Color filter monthly soft cloth and glass cleaning fluid Beam shape monthly soft cloth and glass cleaning fluid Dimmer Shutter yearly va...

Страница 23: ...white plus 1x CTC 5600k 1x CTC 3300k Beam shape Step less Beam shape Frost filter Motor driven focus from near to far away Zoom Motor driven variable angle of reflected beam from 8 to 22 Shutter Stro...

Страница 24: ...ption of Device 5 DIN VDE 0711 217 7 Display 15 DMX 9 DMX Adresse 11 E Error Messages 18 F Fan 15 Fuse 9 I Injury of the retina 6 Invert 13 M Maintenance 21 Measures 23 Mounting 7 P Pan movement 23 Po...

Страница 25: ...GLP German Light Production 1 0 25...

Отзывы: