GLP Fusion Stick FS20 Скачать руководство пользователя страница 6

www.glp.de

 

 

 

Fusion Stick FS20 

Quick Start and Safety Manual Rev. A 

 

Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at 
the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s 
Mains OUT (Thru) connector to another fixture’s Mains IN connector. 

 

Use minimum 14 AWG or 1.5 mm

2

 power input and relay cables that are minimum 

16 A-rated and temperature-rated to suit the application. In the USA and Canada 
the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be 
type H05VV-F or equivalent.  

 

Do not connect devices to power in a chain if the total maximum current draw of all 
the devices in the chain when added together will exceed the current rating of any 

cable or connector used at any point in the chain. The supplied power input cable 
is rated as follows: 

US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft. 

EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m. 

Do not connect more than four (4) Fusion Stick FS20 fixtures to power in a chain at 
100-120 V, 60 Hz. 
Do not connect more than eight (8) Fusion Stick FS20 fixtures to power in a chain at 
200-240 V, 50 Hz. 

 

The voltage and frequency at the Mains OUT socket are the same as the voltage 

and frequency applied to the Mains IN socket. Only connect devices to the Mains 
Out socket that accept this voltage and frequency. 

 

Fusion Stick FS20 fixtures do not have a user-replaceable fuse. If you suspect that a 
fuse has blown, disconnect the fixture from power and send it to a technician 

authorized by GLP for repair. 
 

 

Fire safety and protection from burns 

 

Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F. 

 

The surface of the fixture’s casing can reach up to 80° C / 176° F during operation. 
Avoid contact by persons and materials. Do not install the fixture in a location where 
there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes 

before handling 

 

Keep the fixture well away from flammable materials. 

 

Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m / 8 in. away 
from the fixture. 

 

Ensure that there is free and unobstructed airflow around the fixture.  

 

Do not illuminate surfaces within 0.2 m / 8 in. of the fixture. The light output from the 
fixture is powerful enough to cause burns or fire in illuminated objects at very close 
range. 

 

Do not place any optical components other than Fusion Stick FS20 accessories from 

GLP onto the front of the fixture.  

Содержание Fusion Stick FS20

Страница 1: ...Fusion Stick FS20 Quick Start and Safety Manual Software version 1 0 1 7...

Страница 2: ...ll affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the i...

Страница 3: ...ons 14 Securing fixtures with a safety cable 14 Mounting brackets 15 Using FS20 Locking Pins 16 Standing horizontally on a surface 16 Installing on a surface at any angle 17 Installing on a rigging tr...

Страница 4: ...eatures and control of FS20 fixtures The FS20 DMX Channel Index available for download from www glp de The Channel Index is a separate guide to the DMX control channel layout and DMX commands availabl...

Страница 5: ...s manual Observe all markings in this manual and on the fixture Refer all repairs and any service operation not described in this manual to a technician authorized by GLP The light source in this fixt...

Страница 6: ...240 V 50 Hz The voltage and frequency at the Mains OUT socket are the same as the voltage and frequency applied to the Mains IN socket Only connect devices to the Mains Out socket that accept this vol...

Страница 7: ...from the fixture May be harmful to the eyes Do not look at the fixture s light output with optical instruments or any device that may concentrate the light output Make sure that persons near to or wo...

Страница 8: ...on hardware is in perfect condition Fasteners must be steel grade 8 8 strength or better Rigging clamps must be half coupler type that completely encircle the rigging truss chord If the fixture is ins...

Страница 9: ...product warranty Avoiding damage from light sources and heat Do not point the front of the fixture towards the sun or other strong light sources Strong light can cause internal damage to the fixture...

Страница 10: ...the item is protected against the entry of water from rain projections and low pressure jets as well as the entry of dust When assembling connectors and installing them on cable follow the manufactur...

Страница 11: ...s in Service on page 27 Transportation and storage If fixtures have been fastened together with locking pins remove the pins and separate the fixtures before transport Do not transport fixtures that a...

Страница 12: ...de fastening points B AC mains power IN Neutrik powerCON TRUE1 C DMX IN 5 pin XLR D Mounting bracket with quarter turn fasteners E Control panel with OLED display F DMX OUT THRU 5 pin XLR G AC mains p...

Страница 13: ...can be fastened to a level surface or suspended from a suitable structure as directed in this manual Power and data can be daisy chained and fixtures interlocked for ease of installation The FS20 is n...

Страница 14: ...options An FS20 fixture may be installed in one of the following ways Standing horizontally on a horizontal surface using two FS20 Tilt Brackets as a floor stand Standing vertically on a horizontal su...

Страница 15: ...k of the fixture Check that the fixture is now secured Mounting brackets A pair of tilt brackets for fastening the fixture to a surface at any angle or placing the fixture on a horizontal surface is s...

Страница 16: ...ing pulled out of the channels Standing horizontally on a surface To place an FS20 fixture standing horizontally on a stable horizontal surface Install two FS20 Tilt Brackets on the fixture as describ...

Страница 17: ...be suitable for their purpose and the installation environment In a temporary installation secure the fixture with a safety cable as described in Securing fixtures with a safety cable on page 14 if th...

Страница 18: ...s using Clamp Brackets To install the FS20 on a rigging truss or pipe using rigging clamps and optional Clamp Brackets Check that the truss or pipe is secure and can safely hold the weight of fixtures...

Страница 19: ...locking pins may be used for alignment purposes only Vertical suspension from a rigging structure You can install the FS20 hanging vertically downwards from a rigging structure if you use the FS20 Ve...

Страница 20: ...on page 19 Check that the installation will be safe and that the rigging clamp and safety cable are approved for the total weight of all the fixtures in the chain See Figure 12 Have two FS20 Locking...

Страница 21: ...Bolt the End Plate from the FS20 Vertical Adapter Set to the FS20 Base Plate using the four supplied XXXXXXXXXXXXX bolt size Are the bolts supplied XXXXXXXXXXXXX bolts A Note the position of the lock...

Страница 22: ...tly Then press the buttons on the Locking Pins and press them fully into the locking channels before releasing the buttons Check that both Locking Pins are locked into position and that the fixtures a...

Страница 23: ...voltage or to an external dimmer The FS20 does not have a power ON OFF switch Power is applied to the fixture as soon as the power cable becomes live The FS20 has a 3 conductor Neutrik powerCON TRUE1...

Страница 24: ...s in total to power in one chain at 200 240 V 50 Hz The power input cable supplied with the fixture is rated 16 A maximum Add together the maximum current draw ratings of all the devices that you inte...

Страница 25: ...e digital 110 Ohm DMX cable with IP65 5 pin XLR connectors to supply DMX data to fixtures Keep connectors sealed with their rubber caps at all times when not in use The FS20 has two 5 pin XLR sockets...

Страница 26: ...ower input connector supports hot plugging and connecting and disconnecting a live power cable is an option especially if you need to shut down power urgently but it is still good practice to shut dow...

Страница 27: ...xture as you may scratch these surfaces Installing a glare shield The FS20 is supplied with a glare shield that can be installed on the front of the fixture to reduce lateral light spill if required F...

Страница 28: ...ssary but if the fixture is installed at any other angle than horizontal it may be possible for the diffuser to slide out of the fixture and cause injury or damage In this case insert the two grub scr...

Страница 29: ...lse effects Control Control systems DMX RDM DMX channel footprint 4 6 12 17 27 32 80 92 depending on mode Pixel mapping options Whole fixture as one pixel 20 individual pixels Setting and addressing O...

Страница 30: ...inum Color Silver Thermal Cooling Convection Minimum ambient temperature 10 C 14 F Maximum ambient temperature 40 C 104 F Max total heat dissipation calculated 1130 BTU hr Included items Power cable w...

Страница 31: ...German Light Products Fusion Stick FS20 Quick Start and Safety Manual Rev A 31 11 Dimensions FS20 with folding brackets All dimensions are in millimeters Folding brackets...

Страница 32: ......

Отзывы: