![GLP Fusion Stick FS20 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/glp/fusion-stick-fs20/fusion-stick-fs20_quick-start-and-safety-manual_2234658006.webp)
www.glp.de
6
Fusion Stick FS20
Quick Start and Safety Manual Rev. A
•
Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at
the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s
Mains OUT (Thru) connector to another fixture’s Mains IN connector.
•
Use minimum 14 AWG or 1.5 mm
2
power input and relay cables that are minimum
16 A-rated and temperature-rated to suit the application. In the USA and Canada
the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent.
•
Do not connect devices to power in a chain if the total maximum current draw of all
the devices in the chain when added together will exceed the current rating of any
cable or connector used at any point in the chain. The supplied power input cable
is rated as follows:
-
US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
-
EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m.
Do not connect more than four (4) Fusion Stick FS20 fixtures to power in a chain at
100-120 V, 60 Hz.
Do not connect more than eight (8) Fusion Stick FS20 fixtures to power in a chain at
200-240 V, 50 Hz.
•
The voltage and frequency at the Mains OUT socket are the same as the voltage
and frequency applied to the Mains IN socket. Only connect devices to the Mains
Out socket that accept this voltage and frequency.
•
Fusion Stick FS20 fixtures do not have a user-replaceable fuse. If you suspect that a
fuse has blown, disconnect the fixture from power and send it to a technician
authorized by GLP for repair.
Fire safety and protection from burns
•
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F.
•
The surface of the fixture’s casing can reach up to 80° C / 176° F during operation.
Avoid contact by persons and materials. Do not install the fixture in a location where
there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes
before handling
•
Keep the fixture well away from flammable materials.
•
Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m / 8 in. away
from the fixture.
•
Ensure that there is free and unobstructed airflow around the fixture.
•
Do not illuminate surfaces within 0.2 m / 8 in. of the fixture. The light output from the
fixture is powerful enough to cause burns or fire in illuminated objects at very close
range.
•
Do not place any optical components other than Fusion Stick FS20 accessories from
GLP onto the front of the fixture.
Содержание Fusion Stick FS20
Страница 1: ...Fusion Stick FS20 Quick Start and Safety Manual Software version 1 0 1 7...
Страница 32: ......