![GLP Fusion Stick FS20 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/glp/fusion-stick-fs20/fusion-stick-fs20_quick-start-and-safety-manual_2234658020.webp)
www.glp.de
20
Fusion Stick FS20
Quick Start and Safety Manual Rev. A
Bolt the rigging clamp securely to the omega clamp and fasten the omega clamp
to the KNV End Plate A using the clamp’s quarter-turn fasteners. Turn both fasteners
a full 90° to lock them.
As soon as you suspend the fixture from a truss using the rigging clamp, install a
safety cable as described in ‘
Securing fixtures with a safety cable
’ on page 14 if
there is any risk that the fixture will cause injury or damage if it falls.
Suspending multiple fixtures vertically
Warning!
You can use locking pins and channels in fixtures to support weight
only when fixtures are fastened together in a vertical chain – do not use
them to support the weight of a fixture at any other angle than hanging
vertically downwards.
Warning!
Do not fasten more than six (6) fixtures to each other in one
suspended vertical chain.
You can suspend up to a maximum of six (6) FS20 fixtures in total in an interconnected
vertical chain to give an unbroken line of pixels. To create a hanging vertical chain:
Suspend the first fixture as described in ‘
Vertical suspension from a rigging structure
’
on page 19. Check that the installation will be safe and that the rigging clamp and
safety cable are approved for the total weight of all the fixtures in the chain.
See Figure 12. Have two FS20 Locking Pins
A
ready.
Lift the second fixture up to the first so
that the locking channels
B
in the fixtures
mesh with each other.
Push the two locking pins
A
into the
channels
B
in both fixtures. Press the
button on each locking pin so that you
can push the pin fully into its channel.
When the pin is fully engaged, release
the button and check that the button is in
the fully out position so that the pin is
locked in place. Check that the pins now
lock the two fixtures together.
If required by locally applicable
regulations, secure the second fixture by
using a safety cable to fasten the safety cable attachment eyelets in the brackets
on the back of the first and second fixtures to each other so that the safety cable
will catch the second fixture if it falls. In some regions (where DGUV-215-313 is
applicable, for example) the use of two independent locking pins means that use
of a safety cable is not required.
Continue fastening fixtures to each other as described above to form a vertical
chain. Do not create a chain that contains more than six (6) fixtures in total.
B
A
Figure 12. Locking pins used for
creating a vertical chain
Содержание Fusion Stick FS20
Страница 1: ...Fusion Stick FS20 Quick Start and Safety Manual Software version 1 0 1 7...
Страница 32: ......