1 General
1.3 Data
Gas connection -
from the service cock
Total weight -
54kg
Injector
- upper -
Bray 18/180
- lower -
Bray 18/320
Burner pressure setting
- cold -
13.0mbar 5.2in wg
- hot -
13.2 mbar 5.3in wg
Heat input
- gross
6.7kW - 22,750Btu/h
Heat output -nominal
4.03kW - 13,670Btu/h
Fire serial number -
on chassis - visible when front
casting removed
Data label -
Inside of right hand side panel
The fire front burner is lit by means of a battery operated
electronic spark generator unit.
1.4 Fire Front Location
This fire front can only be fitted to a Glow-worm 45/2 or 56/2
back boiler unit, which itself has been fitted in accordance with
the Glow-worm Installation and Servicing Instructions.
The back boiler must be correctly positioned in the builder’s
opening as the fire front is located by connection to it.
The back boiler air duct acts as a support for the fire front.
The top of the fire front must be secured to the vertical fire front
fixing wall face. This wall face may be a chimney breast or
surround, see diagram 1. (Instructions for Use).
The fire front flue spigot sticks out into the back boiler flue
collector assembly.
The gas supply is taken from the back boiler gas service cock.
1.5 Clearances
Restrictions must not be placed around the assembled fire
front, see diagram 1. (Instructions for Use).
A shelf or surround of a maximum depth of 150mm may be
fitted, provided clearances are as shown in
diagram 1. (Instructions for Use). However, for every extra
25mm above the fire front the depth of the shelf may be
increased by 25mm.
Combustible furniture or materials must not be placed closer
than 1metre in front of the fire front.