11 Inspection and maintenance
22
Installation and maintenance instructions SUSTAIN ..s 0020200967_00
11.2
Procuring spare parts
The original components of the product were also certified
as part of the declaration of conformity. If you do not use
certified Glow-worm original spare parts for maintenance
or repair work, this voids the conformity of the product. We
therefore strongly recommend that you install Glow-worm
original spare parts. Information about available Glow-worm
original spare parts is available by contacting the contact
address provided on the reverse of this document.
▶
If you require spare parts for maintenance or repair work,
use only Glow-worm original spare parts.
11.3
Removing the gas-air mixture unit
Note
The gas-air mixture unit consists of three main
components:
–
Ventilator
–
Gas valve,
–
Burner cover
1.
Switch off the product via the main switch.
2.
Close the gas isolator cock.
3.
Remove the front casing. (
→
Page 10)
B
A
1
C
2
4.
Push the clip
(1)
upwards.
5.
Remove the flue pipe
(2)
.
3
4
5
A
B
6.
Remove the air intake pipe
(3)
.
7.
Remove the plugs from the gas valve
(4)
and from the
fan
(5)
.
A
C
D
B
6
8.
Remove the gas-air mixture unit
(6)
.
7
7
8
9.
Remove the burner seals
(7)
and the burner
(8)
.
10. Check the burner and the heat exchanger for damage
and dirt.
11. If necessary, clean or replace the components accord-
ing to the following sections.
12. Install the two new burner seals.
Содержание ENERGY 12s-A