background image

Содержание 32-40C

Страница 1: ...oid and no warranty of any kind shall apply If the equipment has been changed altered modified or repaired by other than a qualified service technician during or after the 12 month limited warranty period then the manufacturer shall not be liable for any incidental or consequential damages to any person or to any property which may result from the use of the equipment thereafter Some States do not...

Страница 2: ...ION Specifications 1 Installation I 2 SECTION TWO USERS GUIDE Warranty 1 Operation 2 CookingHints 6 Maintenance 8 SECTION THREE SERVICE Adjustments I O a _ 1 Service 4 TroubleShooting D 5 Schematic Drawings 7 SECTION FOUR PARTS PartsList 1 CAUTION POST IN PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED THIS INFORMATION SHALL BE OBTMNED FROM LOCAL GAS SUPPLI...

Страница 3: ... RATE 1NO t F MANIFOLD A PRESSURE IN W C RATE NO L Jl C Dl C SI t 1007596 Nat 6 55 000 BTLlslHr s g 8O K Hr 2 Adj N A 0 NIA N A 0 N A 1007599 Prop 10 45 000 BTUslHr 2 I g5 ooApBpT v r 2 Adj N A 0 N A N A 0 NIA 55 000 1007598 1008742 Nat 6 BTUslHr S g 80 iy Hr 2 Adi 32 000 BTUs Hr 5 Approx 800 BTUsiHr 018 Prop 10 1007599 45 000 BTUslHr 1 i 5 8O Hr Adi 32 000 BTUslHr 010 I 1 Nat 6 55 000 set 1008744...

Страница 4: ... load 4 The regulator must have a pressure adjustment range to allow adjustment to the manifold pressure on the appliance rating plate 5 Unless the manifold pressure of all connected appliances is the same a separate regulator must be supplied for each unit s to indicate unit or units having a differing manifold pressures 6 If applicable the vent line from the gas appliance pressure regulator shal...

Страница 5: ...T ALSO BE PROVIDED FOR SERVICING AND FOR OPERATION WARNING ALL UNITS MUST BE INSTALLED IN SUCH A MANNER THAT THE FLOW OF COMBUSTION AND VENTILATION AIR ARE NOT OBSTRUCTED PROVISIONS FOR AN ADEQUATE AIR SUPPLY MUST ALSO BE PROVIDFED DO NOT OBSTRUCT THE FRONT OF THE UNIT AT THE TOP BY THE CONTROL PANEL OR THE BOTTOM JUST BELOW THE OVEN COMPARTMENT AS COMBUSTION AIR ENTERS THROUGH THESE AREAS L I MIN...

Страница 6: ...les in the broiler wing as a guide drill six 6 5 32 t 156 dia holes and secure with six 6 lO x l 2 sheet metal screws MODEL 32 4OC CO32 40C Remove the top six 6 lO x l 2 sheet metal screws from the appropriate side of the flue cover on rear of broiler Slip the flange of the broiler wing under the flange of the flue cover Align holes and secure by reinstalling six 6 lO x l 2 sheet metal screws NOTE...

Страница 7: ...TTERY Each unit has been labeled with the Model No Factory Order No Item No if provided and battery left to right position 1 2 3 4 5 6 7 Position the center range of the battery and carefully level unit Use a long spirit level four ways across front top rail and the rear collar plate and along each edge Remove all valve panels Mark so they will be returned to their respective unit Bring up adjacen...

Страница 8: ...UNTING PROCEDURE If mounting holes are pre drilled remove screws attach filler and secure with same screws If mounting holes are not pre drilled or if pre drilled holes do not align properly drill holes using an 11 64 171 dia drill and secure with lO x slotted truss head sheet metal screws FIG 3 FLAT TYPE FRONT FILLER 1692 Black 1692SS Stainless Steel APPLICATION Fryer or Cabinet Base Unit batteri...

Страница 9: ...ON Convection Oven Base Unit on Left and any Unit on Right MOUNTING PROCEDURE 1 RIGHT SIDE OF THE CONVECTION OVEN BASE UNIT AT CONTROL PANEL Loosen the two screws on the right side of the front filler panel Align the two slots in the front filler with the two screws Push filler in until it is flush with the front of the front filler panel and retighten the two screws 2 For Standard Oven Base Units...

Страница 10: ...TOP FILLER FOR BATTERY INSTALLATIONS PART NUMBER UNIT ON LEFT UNIT ON RIGHT 1164484 BROILER OR FRY TOP RANGE 14 POT FRYER 1164485 14 POT FRYER BROILER OR FRY TOP RANGE 1164487 BROILER OR FRY TOP RANGE 18 POT FRYER 1164486 18 POT FRYER BROILER OR FRY TOP RANGE 1164492 BROILER OR FRY TOP RANGE DRAIN CABINET 1164491 DRAIN CABINET BROILER OR FRY TOP RANGE 1164488 32BC OR 32 40C BROILER ANY RANGE 11644...

Страница 11: ...le for consequential or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtime or premium labor rates the owner shall be charged for the difference between normal service rates and such premium rates In all circumstances a maximum of one hundred miles in travel and two and one half hours 2 5 travel ti...

Страница 12: ...IN BURNER IGNITION FAILURE A 5 MINUTE PURGE PERIOD MUST BE OBSERVED PRIOR TO RE ESTABLISHING THE IGNITION SOURCE IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN EQUIPMENT AT THE MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE TO LIGHT CONVECTION OVENS ON SECTIONAL FRONT MANIFOLD UNITS Your oven has electronic ignition NO MATCHES required Fig 7 1 Locate OVEN knob 1 ov...

Страница 13: ... door raise hold down clips and remove oven bottom so burner is visible Turn oven burner to OFF Remove panel from spring compartment below oven door Depress RED button on safety valve and light pilot New installations may require time to bleed air from system before pilot will become steady The pilot flame should impinge on the bulb to cause it to glow red If flame is too long and soft bulb may be...

Страница 14: ...perature inside of the box housing the controls reaches 150 F at its sensing point It will run continuously until the tempera ture inside of the control box drops to 135 F The cooling blower operates independent of the power switch therefore eliminating any control damaging residual heat rise after the unit has been completely shut down For further protection of the control box controls if the coo...

Страница 15: ...n and place the power switch in the ON position C SPARK IGNITER FAILURE In the event the spark igniter fails the unit may still be operated by carefully following these instructions 1 Turn thermostat to the OFF position 2 Turn power switch to the OFF position 3 WAIT A MINIMUM OF 5 MINUTES BEFORE PROCEEDING 4 Turn power switch to the ON position 5 Immediately light pilot with a long match 6 After 3...

Страница 16: ...an load POTATOES BAKING 8 OZ SIZE Wash and wrap in potato foil Place 30 potatoes on 18 x 24 bun pan 3 pans per load Bake in 400 F oven for 1 hour TOP ROUND OF BEEF NO 168 Set oven at 250 F Place trimmed roast on pan For 14 16 pounds 140 rare 14 minutes pound 150 medium 16 minutes pound 160 well done 17 minutes pound SUGGESTIONS Convection Type Oven If cakes are dark on the sides and not done in th...

Страница 17: ...0 350 3 4 Baked potatoes 8 oz 60 400 3 30 wrapped Pre blanched potatoes frozen 16 400 3 5 lb Fish portions precooked breaded 3 oz Macaroni cheese 6 lb 40 temp 16 400 45 400 3 32 3 2 6 lbs Lasagne w meat sauce 6 lb 40 temp Lasagne w meat sauce 6 lb frozen Salisbury steak w gravy 6 lb 60 350 75 350 3 2 6 lbs 3 2 6 lbs 40 temp 45 400 3 2 6 lbs Top round of beef No 168 14 lb rare 14 lb medium 14 lb we...

Страница 18: ...t LOW temperature use ordinary soap and water with or without detergent applied with a sponge or cloth Dry thoroughly with a clean cloth 2 To remove grease and food splatter or condensed vapors that have BAKED on the equipment apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines on the metal Rubbing cleanser as gently as possible in the dir...

Страница 19: ...g can be cleaned in a similar manner The side rear and top lining should be wiped only with a cloth dampened with a mild detergent and water Avoid using excessiveamount of water asthis may drip into burner compartment and deteriorate the metal in that area Donot use strong commercial cleaners or abrasive pads on these sides back or top linings OVEN INTERIOR Convection Type Oven CAUTION WHENEVER SE...

Страница 20: ...in accessibility The pilot flame is properly adjusted when it is just large enough to maintain a glowing red color of the flame switch capillary bulb BURNER ADJUSTMENTS 1 Obtain access to burner air shutter A On broilers remove screens on right and left sides B On oven for 32 400 remove panel just below oven door 2 Turn valve or thermostat to maximum or full ON position 3 Loosen screw which holds ...

Страница 21: ...t until flame cuts down to bypass After sufficient time check tempera ture If the temperature does not read within 15 degrees of the dial setting recalibrate as follows Hold calibration plate and loosen the two calibration lock screws until the plate can be moved independently of the control Turn calibration plate so that the instrument or thermometer reading is in line with the indi cator mark as...

Страница 22: ...or the temperature to stabilize 7 Read the pyrometer or thermometer immediately after the light goes out for the third time and again immediately after it comes on the next time 8 If the average of these readings and the dial setting vary by more than 15 degrees recalibrate be following the instructions outlined below TO RECALIBRATE NOTE Recalibration should be attempted only by a competent servic...

Страница 23: ... the controls are accessibleby removing the control box cover C THERMOSTATS To totally remove the thermostats after the control box has been slid out as described in B further stepsmust be taken 1 Removethe control box wiring strain relief stop located on the top of the control box 2 Slide out the control box far enough to disconnect the wiring harness plugs 3 Removethe thermostat capillary tie do...

Страница 24: ...n deposits Incorrect gastype supplied to battery Incorrect supply pressure Only someranges in a battery produceexcessivecarbon deposits burners Incorrect orifices Primary air not adjusted properly Only somepilots produce Pilot gasnot adjusted properly excessivecarbon deposits Incorrect pilot orifice Topburner or broiler burner Manual valve for burner in OFF position not oven will not comeon Pilot ...

Страница 25: ... Unit gas line shutoff in closed position C Pilot line valve in closed position D Pilot line solenoid Pilot ignites but burners will not light when thermostat calls for heat Cook light on A Main gas solenoid B Flame switch bulb in correct position C Flame switch Unit will function properly for a period of time and then shut down oven circulating blower and oven burners Oven will begin to function ...

Страница 26: ...SERVICE e r RADIANT BROILER SECTION THREE SERVICE PAGE 7 ...

Страница 27: ...RADIANT BROILER SECTION THREE SERVICE PAGE 8 Litho in U S A 4 92 ...

Страница 28: ...SERVICE e I r l L i T RADIANT BROILER SECTION THREE SERVICE PAGE 9 ...

Страница 29: ......

Страница 30: ...164807 Spark Electrode 1168300 Door Switch Assy Single Units 1142000 Door Switch B03 00028 Door Switch Assy Left Side 1165733 Oven Burner Double Ovens See Kit Standing Pilot 1008744 Oven Burner Orifice Nat 44 1008753 Oven Burner Orifice LP 53 B SUFFIX OVEN PARTS 1165510 Gas Solenoid Assy 1165512 Pilot Line Valve PART NO DESCRIPTION 1165521 Blower Wheel 1165652 Oven Rack 1170193 Thermostat 1010398 ...

Страница 31: ...10398 Oven On Off Valve Oven On Off Knob Oven Orifice Nat Oven Orifice LP Oven Rack Oven Fire Plate 1118198 Prod prior to July 1984 Oven Fire Plate Prod during after July 1984 Oven Bottom Oven Door Assy Black 1024195 Oven Door Assy SS 1024194 Oven Door Handle Kit 4440002 Oven Door Hinge Assy Oven Door Spring Quadrant Bracket Assy Quadrant Left Spring Hook Right Spring Hook Warming Oven Bottom Angl...

Страница 32: ...UCT X50 WIRE CONNECTORS VA TRANSFORMER 220V UNITS TERMlNAL BLOCK 220 VOLT UN ITS BLOWER ASSEMBLY DOOR CHAIN ASSEMBLY I DOOR SPRING Diagram 2 FLAME SWITCH SOLENOID f ACCESS PANEL TO TERMINAL BLOCK FOR 220 VOLT UNITS 7 1 4 x h OBR 15 DOOR SWITCH PILOT ADJUSTMENT VALVE Diagram 3 TRANSFORMER 8 LINE FOR 220 VOLT UNITS ONLY 3 4 RADIANT BROILER SECTION FOUR PARTS PAGE 3 ...

Страница 33: ...sional service may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and type of your unit i I m southbend A MIDDLEBY COMPANY PART 1164419 1100 Old Honeycutl Road Fuquay Varina NC 27526 919 552 9161 FAX 552 9798 919 800 348 2558 ...